Download Comtech EF Data CDD-880 Product specifications

Transcript
CDD-880 Multi Receiver Router
Introduction
1.4.3
Revision 0
MN-CDD880
Environmental and Physical
Parameters
Temperature
Humidity
Power Supply
Operating
Voltage
Specifications
Operating
32 to 122°F (0 to 50°C)
Storage
-4 to 158°F (-20 to 70°C)
Operating
95% maximum, non-condensing
Storage
99% maximum, non-condensing
AC
Includes an on/off switch
DC
Includes an on/off switch and an input filter per PL-0000551 and PL/10312-1 Kits
AC
100 – 240 Volts AC +6%/-10% autosensing (total absolute max. range is 90 – 254 volts AC)
DC
48 Volts nominal (total range is 36 to 60 volts)
Power Consumption
60 W typical
Fuse
120/230 VAC: T3.15A, slow-blow 20 mm
48VDC (38 to 60 VDC): T8.0A, slow-blow 20 mm
Physical Dimensions
1RU high x 19 inches wide x 16 inches deep
( 43.8 mm h x 482.6 mm w x 406 mm d)
Weight
7 lbs (3.2 kg)
Agency Approvals
CE Mark
FCC Part 15, Class B
1–10