Download Simrad SP90 - REV E Installation manual
Transcript
Simrad SP90 Measurements/calculations Value Unit Example Measured time delay (t) msec 5 Distance from hydrophone to transducer r = 1.5xt meter 7.5 20 log r dB 17.5 volt 0.9 volt 0.32 dB//1V --9.9 volt 1.8 volt 0.64 U Hydr = 20 log U(RMS) dB//1V --3.9 Bearing (° Stb/Port) ° --36 Tilt angle ° 0 Depth below keel meter 3 Water temperature °C 18 Hydrophone voltage U(p--p) in Omni U(RMS) = U(p--p)/2/√2 U Hydr = 20 log U(RMS) Hydrophone voltage U(p--p) in 11 degrees U(RMS) = U(p--p)/2/√2 General information Table 4 Measurements results SL = U Hydr -- M + 20 log r OMNI 11° U Hydrophone dB//1V --9.9 M total dB//1V/µPa --209.6 20 log r dB 17.5 SL OMNI dB//µPa 217.2 U Hydrophone dB//1V --3.9 M total dB//1V/µPa --209.6 20 log r dB 17.5 SL 11° dB//µPa 223.2 Table 5 Source level (SL) for Onmi and 11 degrees 16 Fill in the M total from the Test hydrophone data table into the Source Level (SL) table. → 17 The Test Hydrophone Data table is shown as table 3 on page 151. Perform the SL calculations as detailed in the table, and compare the result with the specifications for the sonar. - SL Omni: 217 ± 2 dB//µPa - SL 11 degrees: 223 ± 2 dB//µPa 154 851-164510 / Rev.E