Download RedMax REVOLUTION -5.10-BF Technical data
Transcript
RedMax-...-Y RedMax-...-YF Special options ... -CTS ... -VAS E X P L O S I O N P R O O F Electrical connection Modulating / 3-pos. – with / without spring return 24...240 VAC/ DC − + ~ ~ 2 3 UmA UVDC YmA YVDC 5 1 2 3 4 5 6 PA Selection of running time for spring return: Reverse function: Spring return in ~ 10 s = Standard wiring Bridge 3 –4 reverses the Spring return in ~ 3 s = Additional wiring on terminal 5 input and output signals Function and enforcement control of switch a and b in modulating mode: ▪ a closed – Forced-ON (OFF) in acc. to left/right mounting of actuator ▪ b closed – Forced-OFF (ON) in acc. to left/right mounting of actuator Modulating – with / without spring return (no feedback) 24...240 VAC/ DC + − ~ ~ 1 2 3 SB 5.2 T 4 UmA UVDC 5 1 2 3 Selection of running time for spring return: Spring return in ~ 10 s = Standard wiring Spring return in ~ 3 s = Additional wiring on terminal 5 5 6 Reverse function: Bridge 3 – 4 reverses the input signals PA a 1 2 3 b 4 Y: U: 0...10 V / 4...20 mA 0...10 V / 4...20 mA 5 6 PA SB 5.3 1 2 VDC/mA 3 4 UmA UVDC 5 6 PA Attention ! During commissioning apply a self adjustment drive. Regard duty cycle at motor running times ! Never use spring return actuators without external load. Accessory RedBox – adaptable terminal box supply * 24...240 VAC/DC ± 10 % RedBox 4 Reverse function: Bridge 3 – 4 reverses the input and output signals Attention ! When changing 3-position mode into modulating regard function, see page 4 – Parametrisation D) 5 ! Safe area 3 Selection of running time for spring return: Reverse function: Spring return in ~ 10 s = Standard wiring Bridge 3 – 4 reverses Spring return in ~ 3 s = Additional wiring on terminal 5 the output signals 3-pos. control mode: ▪ a closed, b open – ON (OFF) in acc. to left /right mounting of actuator ▪ b closed, a open – OFF (ON) in acc. to left /right mounting of actuator Installation Ex area – zone 2, 22 2 Self adjustment: To adjust the signal input /output to the angle of rotation of the damper / valve the button (T) must be pushed for a minimum of 3 sec. VDC/mA 4 1 3-pos. – with / without spring return + feedback PE 3 5 24...240 VAC / DC + − ~ ~ PE 2 4 Selection of running time for spring return: Spring return in ~ 10 s = Standard wiring Spring return in ~ 3 s = Additional wiring on terminal 5 Self adjustment: To adjust the signal input / output to the angle of rotation of the damper/valve the button (T) must be pushed for a minimum of 3 sec. YmA YVDC 1 VDC/mA PE b 4 Self adjustment: To adjust the signal input / output to the angle of rotation of the damper /valve the button (T) must be pushed for a minimum of 3 sec. T 1 T a VDC/mA Modulating – with / without spring return (no enforcement) SB 5.1 24...240 VAC / DC − + ~ ~ Self adjustment: To adjust the signal input /output to the angle of rotation of the damper /valve the button (T) must be pushed for a minimum of 3 sec. YmA YVDC PE SB 5.0 For electrical connection inside hazardous areas a terminal box is required (e.g. RedBox). An over-current protection fuse < 10 A has to be provided by installer. Note: the initial current is appr. 2 A for 1 second. T All actuators are equipped with a universal supply unit working at a voltage range from 24...240 VAC/DC. The supply unit is self adjusting to the connected voltage ! The safety operation of the spring return function works if the supply voltage is cut. * electrical wiring see diagrams For electrical connection of ...Max actuators inside the hazardous area an Ex-e terminal box is required. RedBoxes are appropriate terminal boxes and placed at the disposal. To adapt the ...Box directly to the actuator housing a mounting bracket type MKK-S is required. RedBox- Y/S for ...Max-...-Y and ...-YF with integral auxiliary switches RedMax-S-Y_en V01 – 4-Feb-2015 Schischek GmbH Germany, Muehlsteig 45, Gewerbegebiet Sued 5, 90579 Langenzenn, Tel. +49 9101 9081-0, Fax +49 9101 9081-77, E-Mail [email protected] www.schischek.com 3/4