Download Siemens SINUMERIK 802D sl Operator`s manual

Transcript
Overview of alarms
06/2009
Cycle alarms
Program Continuation:
61322
Clear alarm with the RESET key. Restart part program
[Channel %1: ] Block %2: Check 4th number of _KNUM
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The specified position of _KNUM includes invalid values. Also check _MVAR.
Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998,
CYCLE114.
Remedy:
Check parameter _KNUM, _MVAR.
61323
[Channel %1: ] Block %2: Check 5th number of _KNUM
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The specified position of _KNUM includes invalid values. Also check _MVAR.
Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998,
CYCLE114.
Remedy:
Check parameter _KNUM, _MVAR.
61324
[Channel %1: ] Block %2: Check 6th number of _KNUM
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The specified position of _KNUM includes invalid values. Also check _MVAR.
Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998,
CYCLE114.
Remedy:
Check parameter _KNUM, _MVAR.
61325
[Channel %1: ] Block %2: Check measuring axis/auxiliary measuring axis
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Parameter for metering shaft _MA has an incorrect value.
Alarm is triggered by: all measuring cycles except for CYCLE979.
Remedy:
Check parameter _MA.
61326
[Channel %1: ] Block %2: Check measuring direction
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Parameter for measuring direction _MD has an incorrect value. Alarm is triggered: CYCLE973,
CYCLE976.
Remedy:
Check parameter _MD.
61327
[Channel %1: ] Block %2: Program reset required
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
NC reset required.
Alarm is triggered: all measuring cycles except for CYCLE973, CYCLE976.
Remedy:
Execute NC reset.
61328
[Channel %1: ] Block %2: Check D number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
D number in parameter _KNUM is 0.
The alarm can be triggered by all measuring cycles.
Remedy:
Check parameter _KNUM.
61329
[Channel %1: ] Block %2: Check rotary axis
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No name assigned to the axis number specified under parameter _RA or axis not configured as rotary
axis. Alarm is triggered: CYCLE998.
2-234
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009