Download RAD Data comm IPmux-1E Specifications
Transcript
IPmux-1/1E Installation and Operation Manual Chapter 4 Troubleshooting and Diagnostics Table 4-1. Event Types Event Description Corrective Action COLD_START The IPmux-1/1E has been powered up None PWR_ACTIVE IPmux-1/1E power supply unit is powered on None FATAL ERR IPmux-1/1E has encountered an internal fatal error The IPmux-1 requires servicing SYS USER RESET IPmux-1/1E was reset by the user None LOS START IPmux-1 has a LOS (loss of signal) state on its E1/T1 port 1. Check the port cable connection 2. Check input signal LOS END The LOS state detected has ended LOF START IPmux-1 has a LOF (Loss of frame synchronization) state on its E1/T1 port 1. Check port cable connection LOF END The LOF state detected has ended None LINE AIS START IPmux-1 has AIS (alarm indicator signal) state on its E1/T1 port Check for a fault at the PDH network, on the receive direction LINE AIS END The line AIS state detected has ended None LINE RDI START IPmux-1 has LINE RDI (remote defect indicator) state on its E1/T1 port Check for a fault at the E1/T1 connectivity on the transmit direction LINE RDI END The LINE RDI state detected has ended None LINE FEBE START IPmux-1 has LINE FEBE state on its E1/T1 port Check for errors in the E1/T1 connection on the transmit direction LINE FEBE END The LINE FEBE state detected has ended None REMOTE FAIL START Ethernet frames are not received by the remote IPmux-1 on the specified connection Check Eth/IP path REMOTE FAIL END Remote fail state has ended None LOCAL FAIL START Ethernet frames are not received by the local IPmux-1 on the specified connection Check Eth/IP path LOCAL FAIL END Local fail state has ended None 2. Check input signal 4-2 Error Detection Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com