Download Quickdata Quikstop-15 User manual

Transcript
QwikData Jumper Configuration
Basic, Bracket and Import Drag Race Packages
J4
Factory Default Settings
No jumper. (Ch 1)
Alternative Settings
1-2. Pull-up to 12V (Ch 1)
2-3. Pull-down to ground (Ch 1)
J16
J15
J14
J16
1-2 Enable Battery Voltage Measurement
2-3. Enable external input for Ch 10
1-2. Enable Accelerometer 1 (Ch 9)
1-2 Enable Battery Voltage Measurement
2-3. Enable external input for Ch 16
1-2 Enable Accelerometer 2 (Ch 10)
2-3. Enable external input for Ch 9
2-3. Enable external input for Ch 16
J9
J8
1-2. Ch 2 (Has Pull-up to 12V)
No jumper. Ch 6
J7
J6
J5
1-2. Ch 5. (Has Pull-up to 12V)
2-3. Ch 4 (Has Pull-down to Ground)
1-2. Ch 3 (Has Pull-up to 12V)
2-3.
1-2.
2-3.
2-3.
1-2.
2-3.
Pull-down to ground (Ch
Pull-up to 12V (Ch 6)
Pull-down to ground (Ch
Pull-down to ground (Ch
Pull-up to 12V (Ch 4)
Pull-down to ground (Ch
2)
6)
5)
3)
QwikData Jumper Configuration
Advanced Drag Race and Circle Track / Road Race Packages
J4
Factory Default Settings
No jumper. (Ch 1)
Alternative Settings
1-2. Pull-up to 12V (Ch 1)
2-3. Pull-down to ground (Ch 1)
J16
J15
J14
J16
1-2 Enable Battery Voltage Measurement
1-2 Enable Accelerometer 2 (Ch 10)
1-2. Enable Accelerometer 1 (Ch 9)
1-2 Enable Battery Voltage Measurement
2-3. Enable external input for Ch 16
2-3. Enable external input for Ch 10
2-3. Enable external input for Ch 9
2-3. Enable external input for Ch 16
J9
J8
1-2. Ch 2 (Has Pull-up to 12V)
No jumper. Ch 6
J7
J6
J5
1-2. Ch 5. (Has Pull-up to 12V)
1-2. Pull-up to 12V (Ch 4)
1-2. Ch 3 (Has Pull-up to 12V)
2-3. Pull-down to ground (Ch 2)
1-2. Pull-up to 12V (Ch 6)
2-3. Pull-down to ground (Ch 6)
2-3. Pull-down to ground (Ch 5)
2-3. Ch 4 (Has Pull-down to Ground)
2-3. Pull-down to ground (Ch 3)
Catalog #91001, 91003, 91004, 91005, 91007, 91009
Rev. 9/06 - RS/mc
Page 46 of 47
©2006 Edelbrock Corporation
Brochure #63-0282