Air-to-water heat pump for outdoor installation
Low temperature air-to-water heat pump
Low temperature air-to-water heat pump
Max. flow temperature 55 °C
Casing colour White aluminium (similar to RAL 9006)
For installation close to walls
LA 11MAS
Air-to-water heat pump for outdoor installation with external temperature controlled WPM 2006 plus heat pump manager.
Sound-optimised through the use of low-noise ‚owl‘s wings‘ ventilator blades. Energy-efficient defrosting by reverse circulation.
High coefficients of performance (COP) thanks to compliance with EN 14511 for larger volume flows on the heat consumption side.
Universal design with optional domestic hot water preparation and flexible expansion possibilities for:
• Bivalent or bivalent-renewable operating mode
• Distribution systems with unmixed and mixed heating circuits
The minimum clearances must be observed for installation close to walls. Integrated flow sensor and soft starter; return sensor and
external temperature sensor included in the scope of supply.
The EVL . . . electric cable for connecting the heat pump and the heat pump manager, must be ordered separately.
Lower operating limit heat source (heating operation) -25 °C; Upper operating limit heat source (heating operation) 35 °C; Refrigerant
R404A; Control voltage ~230 V; Connection heating 1 ˝; Connection voltage 1/N/PE ~230 V, 50 Hz
Order reference
Art.-no.
Heat output 1 compressor /
COP A2/W35
LA 11MAS
363760
7.9 / 3.4
LA 16MAS
363770
11.9 / 3.1
Connection voltage
1/N/PE ~230 V, 50 Hz
Width x Height x Depth
mm
Weight
kg
1050 x 1340 x 852
189
1074 x 1550 x 852
229
Heat output and COP according to EN 14511 at A2/W35.
The air outlet must be positioned at a right angle to the main wind direction if unsheltered outdoor installation is carried out.
11MAS
LA 16MAS
363760
363770
4015627363762
4015627363779
Low temperature air-to-water heat pump
Max. flow temperature 58 °C
Casing colour White aluminium (similar to RAL 9006)
For installation close to walls
LA ..TAS
Air-to-water heat pump for outdoor installation with external temperature controlled WPM 2006 plus heat pump manager.
Sound-optimised through the use of low-noise ‚owl‘s wings‘ ventilator blades. Energy-efficient defrosting by reverse circulation.
High coefficients of performance (COP) thanks to compliance with EN 14511 for larger volume flows on the heat consumption side.
Universal design with optional domestic hot water preparation and flexible expansion possibilities for:
• Bivalent or bivalent-renewable operating mode
• Distribution systems with unmixed and mixed heating circuits
The minimum clearances must be observed for installation close to walls. Integrated flow sensor and soft starter; return sensor and
external temperature sensor included in the scope of supply.
The EVL . . . electric cable for connecting the heat pump and the heat pump manager, must be ordered separately.
Lower operating limit heat source (heating operation) -25 °C; Upper operating limit heat source (heating operation) 35 °C;
Refrigerant R404A; Control voltage ~230 V; Connection heating 1˝; Connection voltage 3/N/PE ~400 V, 50 Hz
Order reference
Art.-no.
Heat output 1 compressor /
COP A2/W35
LA 11TAS
362570
8.6 / 3.4
LA 16TAS
362580
11.7 / 3.2
Connection voltage
3/N/PE ~400 V, 50 Hz
Width x Height x Depth
mm
Weight
kg
1050 x 1340 x 852
193
1075 x 1550 x 852
231
Heat output and COP according to EN 14511 at A2/W35.
The air outlet must be positioned at a right angle to the main wind direction if unsheltered outdoor installation is carried out.
LA 11TAS
16TAS
362570
362580
4015627362574
4015627362581
Reversible air-to-water heat pump
Max. flow temperature 58 °C
Flow temperature cooling min. 7 °C
Casing colour White aluminium (similar to RAL 9006)
Optimised for heating operation
LA 11MSR
Air-to-water heat pump for outdoor installation with external temperature controlled WPM 2006 R heat pump manager and reversible
refrigeration circuit for heating and cooling. Sound-optimised through the use of low-noise crescent wing axial fans and deflector hoods.
Energy-efficient defrosting by reverse circulation und diagonally positioned evaporator. Universal design with optional domestic hot
water preparation and flexible expansion possibilities for:
• Bivalent operation (bivalent-renewable not possible)
• Combined distribution systems for heating and cooling
• Unmixed and mixed heating and cooling circuits
Silent cooling via panel heating/cooling systems requires the use of the room climate station (special accessory) to regulate the flow
temperature on the basis of the air temperature and humidity of a reference room.
The EVL . . R electric cable for connecting the heat pump and the heat pump manager must be ordered separately.
Lower operating limit heat source (heating operation) -20 °C; Upper operating limit heat source (heating operation) 35 °C;
Lower operating limit heat source (cooling operation) 15 °C; Upper operating limit heat source (cooling operation) 40 °C;
Refrigerant R404A; Control voltage ~230 V; Connection heating 1˝; Connection voltage 1/N/PE ~230 V, 50 Hz
Order reference
Art.-no.
Heat output
1 compressor /
COP A2/W35
Cooling capacity
1 compressor /
EER A27/W7
Connection
heating
˝
Width x Height x Depth
mm
Weight
kg
LA 11MSR
342690
8.8 / 3.3
8.8 / 2.8
1
1360 x 1360 x 860
224
Heat output and COP according to EN 14511 at A2/W35.
Cooling capacity and coefficient of performance (EER) according to EN 14511.
If sound protection requirements are very high, we recommend installing double-sphere rubber expansion joints between the heat pump and the
heating system in order to optimise solid-borne sound insulation. KOMP expansion joints available as special accessories.
LA 11MSR
10
342690
4015627342699
www.dimplex.de/en