3-1-3. INIT 2 Initialization 2 process is as follows: Hardware reset Initialize work area/ buffers/flags Start All totoalizer reset including E-journal Menu selection FC/Init2 End Flag clear 3-1-4. INIT code Description Choice Significant number Logical ID (01~32)-----Omissible Program code :: D10 D9 ;;; Always “000” D8 D7 D6 Area code: U.S. Other area (default descriptor in English) (default descriptor in German) (default descriptor in French) (default descriptor in Spanish) (using Arabic character table) :2 :1 :4 :5 :6 :8 : Significant number COM 4 Use remote printer-1 : 0 Significant number COM3 Use remote printer-2 : 0 Use remote display : 3 COM 2 Use slip printer (SP-1300) : 0 Use hand held scanner (HHS-15) : 1 Significant number COM 1 Use XMODEM : 0 Significant number D5 : D4 : D3 : Significant number D2 : D1 3-2. IPL (Initial Program Loading) IPL should be made before initializing when the application software has been modified. 3-2-1. IPL Initial program loading process is as follows: IPL code = 44449999 Start ROM check Baud rate selection Communication port selection IPL by CF card Waiting for IPL TE-7000S/8000F/8500F Reference Manual Store the receiving data to Flash Continue to INIT R-89 www.cashregisters.net