Download Quest Engineering QT ZM66 User manual

Transcript
Q-Tech
Commercial Series
QT ZM66M
Paging Station
User Manual
Contents
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
General Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Front Panel Layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Rear Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Address Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Block Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Dimensional Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . 15
QT ZM66M
User Manual
Safety Precautions
• Be sure to read the instructions in this section carefully before use.
• Make sure you observe the instructions in this manual as to the conventions of safety symbols.
• We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first
and understand the safety symbols and messages so you are thoroughly aware of the potential risks.
1
WARNING
Indicates a potentially hazardous situation which, if
mishandled, could result in death or serious personal injury.
CAUTION
Indicates a potentially hazardous situation which, if
mishandled, could result in moderate or minor personal injury,
and/or property damage.
Q-Tech Commercial Series
QT ZM66M
User Manual
QT ZM66M
User Manual
WARNING
When Installing the Unit
• Do not expose the unit to rain or an
environment where it may be splashed by
water or other liquids, as doing so may
result in fire or electric shock.
• Use the unit only with the voltage
specified on the unit. Using a voltage
higher than that which is specified may
result in fire or electric shock.
• Do not cut, kink, otherwise damage nor
modify the power supply cord. In addition,
avoid using the power cord in close
proximity to heaters, and never place
heavy objects -- including the unit itself -on the power cord, as doing so may result
in fire or electric shock.
2
• Be sure to replace the unit’s terminal cover
after connection completion. Because
high voltage is applied to the speaker
terminals, never touch these terminals to
avoid electric shock.
• Be sure to ground to the earth terminal to
avoid electric shock.
When the Unit is in Use
• Should the following irregularity be found
during use, immediately switch off the
power, disconnect the power supply plug
from the AC outlet and contact your nearest
Quest dealer. Make no further attempt to
operate the unit in this condition as this
may cause fire or electric shock.
• If you detect smoke or a strange smell
coming from the unit.
• If water or any metallic object gets into
the unit
• If the unit falls, or the unit case breaks
• If the power supply cord is damaged
(exposure of the core, disconnection, etc.)
• If it is malfunctioning (no tone sounds.)
• To prevent a fire or electric shock, never
open nor remove the unit case as there are
high voltage components inside the unit.
Refer all servicing to your nearest Quest
dealer.
• Do not place cups, bowls, or other
containers of liquid or metallic objects on
top of the unit. If they accidentally spill into
the unit, this may cause a fire or electric
shock.
• Do not insert nor drop metallic objects or
flammable materials in the ventilation slots
of the unit’s cover, as this may result in fire
or electric shock.
User Manual
Q-Tech Commercial Series
QT ZM66M
QT ZM66M
User Manual
CAUTION
When Installing the Unit
• Never plug in nor remove the power
supply plug with wet hands, as doing so
may cause electric shock.
• When unplugging the power supply cord,
be sure to grasp the power supply plug;
never pull on the cord itself. Operating the
unit with a damaged power supply cord
may cause a fire or electric shock.
• When moving the unit, be sure to remove
its power supply cord from the wall
outlet. Moving the unit with the power
cord connected to the outlet may cause
damage to the power cord, resulting in
fire or electric shock. When removing the
power cord, be sure to hold its plug to
pull.
• Do not block the ventilation slots in the
unit’s cover. Doing so may cause heat to
build up inside the unit and result in fire.
• Avoid installing the unit in humid or dusty
locations, in locations exposed to direct
sunlight, near heaters, or in locations
generating sooty smoke or steam as doing
otherwise may result in fire or electric
shock.
When the Unit is in Use
• Do not place heavy objects on the unit
as this may cause it to fall or break which
may result in personal injury and/or
property damage. In addition, the object
itself may fall off and cause injury and/or
damage.
• Make sure that the volume control is set
to minimum position before power is
switched on. Loud noise produced at high
volume when power is switched on can
impair hearing.
• Do not operate the unit for an extended
period of time with the sound distorting.
This is an indication of a malfunction,
which in turn can cause heat to generate
and result in a fire.
• Contact your Quest dealer for cleaning
recommendations. If dust is allowed to
accumulate in the unit over a long period
of time, a fire or damage to the unit may
result.
3
• If dust accumulates on the power supply
plug or in the wall AC outlet, a fire may
result. Clean it periodically. In addition,
insert the plug in the wall outlet securely.
• Switch off the power, and unplug the
power supply plug from the AC outlet for
safety purposes when cleaning or leaving
the unit unused for 10 days or more. Doing
otherwise may cause a fire or electric
shock.
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be
incorporated in the electrical installation of the building.
Q-Tech Commercial Series
QT ZM66M
User Manual
QT ZM66M
User Manual
General Description
The QT ZM66M 6 zone paging console is able to page individual zones in addition to making “all
call” paging announcements.
Operation
1.   Individual Zone selection, or all call.
Keep button depressed while speaking. A chime tone will be activated on pressing zone button and LED will
light up.
2.   Announcement
After selecting the zone to be paged, keep the button depressed while making the announcement. If other QT
ZM66M consoles are being used, this is prioritized as a first in/first served basis.
3.   Message 3 Activation.
Message 3 has many useful functions. This message may be repeated, or a single message played
continuously. Use of message 3 is made via the alarm button on the front panel of The QT ZM66.
4.   Paging Console has priority over all other sources
5.   Recorded messages
4
User Manual
Three different messages, 60 seconds max each could be recorded. The first and second message are
activate by contact play message on QT ZM66 and they go to all zones. The third message could be only
activated by microphone base console and it goes only to the pre-selected zone. Messages have priority on
all music sources.
6.   Maximum of 6 consoles which may be used.
Q-Tech Commercial Series
QT ZM66M
QT ZM66M
User Manual
Specifications
Sensitivity
-50 / -2 dB 2, 5 / 500 mV
S/N ratio
>68dB
Frequency response
100/17.000Hz(-3dB)
Phantom power
12V
Bass
±12dB
Treble
±12dB
Chime
2 tone active for contact free in priority and BGM
Normal distortion
>0.1%
Main power supply
24 DC
Dimension (mm)
230X150X56
Weight
0.96KG
Max number of microphone bases
6
Q-Tech Commercial Series
QT ZM66M
5
User Manual
QT ZM66M
User Manual
Front Panel Layout
6
7
4
5
MI C
ZO N E 1
ZO N E 2
ZO N E 3
L I N K P O WE R
ALAR M
6
ZO N E 4
ZO N E 5
1
1.   ZONE(1~6)
6 zone activation switches with LED
2.   All Call
Activation switch for all zones with LED
selection
3.   Talk
Hold down while making announcements. If
other consoles are in operation at the same
time, the LED will blink. Please wait before
making an announcement
ZO N E 6
AL L C AL L
TA L K
2
3
4.   Alarm
Alarm message activation switch for
pre-selected zone. The Alarm button operates
message no 3 only. Hold button down for 2
seconds to activate message
5.   Power
Power indicator
6.   Link
Link indicator
7.   MIC
Electret microphone
User Manual
Q-Tech Commercial Series
QT ZM66M
QT ZM66M
User Manual
Rear Panel Layout
P OWE R
24V DC
V O L U ME T R E B L E
3
1
2
1
2
3
B AS S
C HIME
V O L U ME
ID C O NS O L E
L INE IN
L INK O U T
G ND
G ND
+24D C
8
0
10
-10
9
+10
10
-10
+10
11
0
10
12
13
14
15
8.   24V DC Power Supply
24V DC power connection with secure screw
for a potential external power transformer.
The 24v power supply should be used when
the distance between the QT ZM66M and the
QT ZM66 exceeds 50m.
When the distance between the QT ZM66 and
QT ZM66M is greater than 50m, we must use
the 24V DC power input
9.   Volume
Volume control output
10.   Treble
Adjust treble response. Rotate clockwise to
increase treble output and anti clockwise to
reduce it
12.   Chime
Chime Volume Control
13.   ID Console
Dip-switches for microphone base ID (from 1
to 6)
14.   Line IN
7
Rj45 port for connection to QT ZM66M. Two
wires are used for 24 Vdc power provided by
QT ZM66M, two wires for the data bus 485 and
3 wires for 0dB microphone signal.
15.   Link OUT
Connected to the next QT ZM66M
11.   Bass
Adjust bass response. Rotate clockwise to
increase bass output and anti-clockwise to
reduce it
Q-Tech Commercial Series
QT ZM66M
User Manual
QT ZM66M
User Manual
Connections
Network Connection Line
AVIS:
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
IN COM ZONE
PUBLIC ADDRESS SYSTEM
Digital Mixer 6 zone
RELE ZONE CONSOL OUT
+1 +2 +3 +4 +5 +6
MIX MUSIC-PAGE OUT
MUSIC OUT
PAGE OUT
REC
MESSAGE
3 2 1 OFF
PLAY MESSAGE
MESSAGE
1 TIME
ALARM
MESSAGE
VOL.REC VOL.PLAY
+48V VOLUME
PHANTOM CHIME
PRIORITY
COM NO1 NO2
SERIAL NO :
CONTINUOS
~230V/50Hz
T1AL250V
CD
TAPE
OPEN RELE INPUT
ZONE 1 OUT
ZONE 2 OUT
ZONE 3 OUT
ZONE 4 OUT
ZONE 5 OUT
MIC
NORMAL
TUNER
MICRO
CONSOL
ZONE 6 OUT
GAIN
GAIN
CONSOL
VOLUME
A
Network Line
POWER
24VDC
Paging Station
AVIS:
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
SERIAL NO :
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
VOLUME TREBLE
3
1
2
1
2
3
GND
GND
+24DC
0
10
-10
+10
BASS
-10
+10
LINE IN
CHIME
VOLUME ID CONSOL
0
LINK OUT
10
B
8
User Manual
A
Q-Tech Commercial Series
QT ZM66M
B
QT ZM66M
User Manual
Net Production Line Method
1 23 4 5 67 8
1 23 4 5 67 8
B
A
1.   Blue
1.   Blue
2.   White Blue
2.   White Blue
3.   Brown
3.   Brown
4.   White Brown
4.   White Brown
5.   Orange
5.   Orange
6.   White Orange
6.   White Orange
7.   Green
7.   Green
8.   White Green
8.   White Green
9
Note: Network lines must adopt the five categories of twisted-pair with double-layer
shielding, RJ45 connectors must be used with shielded connector
Q-Tech Commercial Series
QT ZM66M
User Manual
QT ZM66M
User Manual
Applications
1 amplifier for music 1 amplifier for voice for 6 zone
Compact disc
100V
OUTPUT
70V 4~16
COM
GND
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS:
LIFT
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
PUBLIC ADDRESS SYSTEM
SERIAL NO :
POWER
FUSE
350W
T6.3AL250V
500W
T8AL250V
650W
T10AL250V
~230V/50Hz
LINK
INPUTS
Voice
FUSE
100V
OUTPUT
70V 4~16
COM
GND
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS:
LIFT
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
POWER
PUBLIC ADDRESS SYSTEM
350W
SERIAL NO :
INPUTS
FUSE
Music
T6.3AL250V
500W
T8AL250V
650W
T10AL250V
~230V/50Hz
LINK
FUSE
AVIS:
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
IN COM ZONE
RELE ZONE CONSOL OUT
+1 +2 +3 +4 +5 +6
OPEN RELE INPUT
ZONE 1 OUT
MIX MUSIC-PAGE OUT
MUSIC OUT
PAGE OUT
PLAY MESSAGE
REC
MESSAGE
3 2 1 OFF
MESSAGE
1 TIME
ALARM
MESSAGE
VOL.REC VOL.PLAY
+48V VOLUME
PHANTOM CHIME
PRIORITY
COM NO1 NO2
PUBLIC ADDRESS SYSTEM
SERIAL NO :
10
CONTINUOS
~230V/50Hz
T1AL250V
TAPE
ZONE 2 OUT
ZONE 3 OUT
ZONE 4 OUT
ZONE 5 OUT
CD
MIC
NORMAL
TUNER
MICRO
CONSOL
ZONE 6 OUT
GAIN
GAIN
CONSOL
VOLUME
POWER
24VDC
AVIS:
Zone 1
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
SERIAL NO :
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
VOLUME TREBLE
3
1
2
POWER
24VDC
AVIS:
Zone 2
1
2
3
GND
GND
+24DC
0
10
-10
+10
2
POWER
24VDC
AVIS:
Zone 3
2
POWER
24VDC
AVIS:
1
2
3
GND
GND
+24DC
10
-10
+10
3
1
2
POWER
24VDC
AVIS:
Zone 5
2
POWER
24VDC
AVIS:
10
-10
+10
Zone 6
User Manual
Q-Tech Commercial Series
QT ZM66M
2
+10
0
BASS
-10
+10
10
-10
+10
BASS
-10
+10
0
10
-10
+10
BASS
-10
+10
CHIME
VOLUME ID CONSOL
0
LINE IN
LINK OUT
10
CHIME
VOLUME ID CONSOL
0
LINE IN
LINK OUT
10
CHIME
VOLUME ID CONSOL
0
LINE IN
LINK OUT
10
SERIAL NO :
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
GND
GND
+24DC
LINK OUT
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
1
2
3
LINE IN
10
SERIAL NO :
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
GND
GND
+24DC
0
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
1
2
3
CHIME
VOLUME ID CONSOL
SERIAL NO :
VOLUME TREBLE
3
1
-10
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
GND
GND
+24DC
LINK OUT
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
1
2
3
LINE IN
10
SERIAL NO :
0
VOLUME TREBLE
3
1
BASS
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
GND
GND
+24DC
0
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
1
2
3
CHIME
VOLUME ID CONSOL
SERIAL NO :
0
VOLUME TREBLE
Zone 4
+10
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
VOLUME TREBLE
3
1
-10
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
VOLUME TREBLE
3
1
BASS
0
10
-10
+10
BASS
-10
+10
CHIME
VOLUME ID CONSOL
0
10
LINE IN
LINK OUT
QT ZM66M
User Manual
6 amplifier one for each zone
Compact disc
AVIS:
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
IN COM ZONE
RELE ZONE CONSOLOUT
+1 +2 +3 +4 +5 +6
OPEN RELE INPUT
ZONE 1 OUT
PUBLIC ADDRESS SYSTEM
MIX MUSIC-PAGE OUT
MUSIC OUT
PAGE OUT
PLAY MESSAGE
REC
MESSAGE
3 2 1 OFF
MESSAGE
1 TIME
ALARM
MESSAGE
VOL.REC VOL.PLAY
+48V VOLUME
PHANTOM CHIME
CONTINUOS
~230V/50Hz
T1AL250V
CD
TAPE
ZONE 2 OUT
ZONE 3 OUT
ZONE 4 OUT
ZONE 5 OUT
MIC
NORMAL
TUNER
MICRO
CONSOL
ZONE 6 OUT
GAIN
POWER
24VDC
AVIS:
2
GND
GND
+24DC
BASS
CHIME
VOLUME ID CONSOL
LINE IN
LINK OUT
100V
OUTPUT
70V 4~16
COM
GND
AVIS:
0
10
-10
+10
-10
+10
0
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
PUBLIC ADDRESS SYSTEM
10
SERIAL NO :
LIFT
POWER
350W
FUSE
T6.3AL250V
500W
T8AL250V
650W
T10AL250V
~230V/50Hz
LINK
INPUTS
FUSE
POWER
24VDC
AVIS:
2
SERIAL NO :
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
1
2
3
GND
GND
+24DC
BASS
CHIME
VOLUME ID CONSOL
LINE IN
11
LINK OUT
100V
OUTPUT
70V 4~16
COM
GND
0
10
-10
+10
-10
+10
0
10
AVIS:
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
PUBLIC ADDRESS SYSTEM
SERIAL NO :
LIFT
POWER
350W
FUSE
T6.3AL250V
500W
T8AL250V
650W
T10AL250V
~230V/50Hz
LINK
INPUTS
FUSE
POWER
24VDC
AVIS:
2
SERIAL NO :
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
1
2
3
GND
GND
+24DC
Zone 5
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
VOLUME TREBLE
3
1
Zone 6
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
VOLUME TREBLE
3
1
CONSOL
VOLUME
SERIAL NO :
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
1
2
3
GAIN
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
VOLUME TREBLE
3
1
PRIORITY
COM NO1 NO2
SERIAL NO :
BASS
CHIME
VOLUME ID CONSOL
LINE IN
LINK OUT
100V
OUTPUT
70V 4~16
COM
GND
AVIS:
0
10
-10
+10
-10
+10
0
10
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
PUBLIC ADDRESS SYSTEM
SERIAL NO :
LIFT
POWER
350W
FUSE
T6.3AL250V
500W
T8AL250V
650W
T10AL250V
~230V/50Hz
LINK
INPUTS
FUSE
Zone 4
POWER
24VDC
AVIS:
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
SERIAL NO :
VOLUME TREBLE
3
1
2
100V
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
1
2
3
GND
GND
+24DC
BASS
CHIME
VOLUME ID CONSOL
LINE IN
OUTPUT
70V 4~16
COM
GND
LINK OUT
AVIS:
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
PUBLIC ADDRESS SYSTEM
0
10
-10
+10
-10
+10
0
SERIAL NO :
10
LIFT
POWER
350W
FUSE
T6.3AL250V
500W
T8AL250V
650W
T10AL250V
~230V/50Hz
LINK
INPUTS
FUSE
100V
POWER
24VDC
AVIS:
2
1
2
3
GND
GND
+24DC
GND
SERIAL NO :
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
BASS
CHIME
VOLUME ID CONSOL
LINE IN
AVIS:
LINK OUT
10
-10
+10
-10
+10
0
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
PUBLIC ADDRESS SYSTEM
SERIAL NO :
LIFT
POWER
FUSE
T6.3AL250V
350W
500W
T8AL250V
650W
T10AL250V
~230V/50Hz
LINK
INPUTS
0
Zone 3
COM
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
VOLUME TREBLE
3
1
OUTPUT
70V 4~16
10
FUSE
Zone 2
100V
POWER
24VDC
AVIS:
2
GND
GND
+24DC
GND
SERIAL NO :
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
1
2
3
COM
PUBLIC ADDRESS SYSTEM
RISK OF ELECTRIC SHOCK
DO NOT OPEN
VOLUME TREBLE
3
1
OUTPUT
70V 4~16
BASS
CHIME
VOLUME ID CONSOL
LINE IN
AVIS:
LINK OUT
0
10
-10
+10
-10
+10
0
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
PUBLIC ADDRESS SYSTEM
SERIAL NO :
INPUTS
LINK
LIFT
POWER
350W
FUSE
T6.3AL250V
500W
T8AL250V
650W
T10AL250V
~230V/50Hz
10
FUSE
Zone 1
Q-Tech Commercial Series
QT ZM66M
User Manual
QT ZM66M
User Manual
Address Set
ID Console Address Set
ADDRESS
ADDRESS DEFINITION
DEFINITION
12
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
User Manual
ADDRESS
ADDRESS
17 17
ON
ON
ON
ON
ON
ON
19 19
ON
ON
20 20
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Q-Tech Commercial Series
QT ZM66M
18 18
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 28
29 29
30 30
31 31
32 32
DEFINITION
DEFINITION
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
QT ZM66M
User Manual
ADDRESS
ADDRESS
33 33
34 34
35 35
36 36
37 37
38 38
39 39
40 40
41 41
42 42
43 43
44 44
45 45
46 46
47 47
48 48
DEFINITION
DEFINITION
ADDRESS
ADDRESS
49 49
ON
ON
ON
ON
ON
ON
51 51
ON
ON
52 52
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
50 50
53 53
54 54
55 55
56 56
57 57
58 58
59 59
60 60
61 61
62 62
63 63
64 64
DEFINITION
DEFINITION
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
13
Q-Tech Commercial Series
QT ZM66M
User Manual
QT ZM66M
User Manual
G ND
Ta lk
A ll z one
A la rm
G ND
MC U
ID
G nd
Block Diagram
G ND
+12v
MA X 485
C ONT R OL
C ONT R OL
14
User Manual
Q-Tech Commercial Series
QT ZM66M
QT ZM66M
User Manual
Dimensional Diagram
UNIT: mm
ZO N E 1
ZO N E 2
L I N K P O WE R
ZO N E 3
ALAR M
ZO N E 4
ZO N E 5
ZO N E 6
AL L C AL L
150 mm
MI C
Front Panel
TA L K
220 mm
15
P U B L IC A D D R E S S S Y S T E M
R IS K O F E L E C T R IC S H O C K
DO N O T O P E N
AV IS :
S E R IA L N O :
R IS Q U E D E C H O C E L E C T R IC U S
-N E P A S Q U V R IR
V O L U ME T R E B L E
P OWE R
24V DC
2
1
2
3
B AS S
C HIME
V O L U ME
ID C O NS O L
L INE IN
L INK O U T
G ND
G ND
+24D C
0
10
-10
+10
-10
+10
0
10
56 mm
3
1
56 mm
220 mm
Back Panel
Side Panel
150 mm
Q-Tech Commercial Series
QT ZM66M
User Manual
QT ZM66M
User Manual
16
User Manual
Q-Tech Commercial Series
QT ZM66M
QT ZM66M
User Manual
17
Q-Tech Commercial Series
QT ZM66M
User Manual
www.questaudio.net
Quest Engineering Pty Ltd
86 Derby St. Pascoe Vale VIC 3055
Ph 613 9354 9133 | Fax 613 9354 9233