Download Datasat RS20i Specifications
Transcript
RS20i Installation and Operating Guide Page 23 1.5.1 Over Temperature Alert If the internal temperature of the RS20i reaches a critical level of 50°C or greater, a red flashing alert indicator will appear. Figure 10. Over Temperature Alert message The flashing alert message appears only on the Home screen. The RS20i will remain operational and the menus can be accessed as usual. The actual circuit board temperatures appear on the System Info page (Setup > System Info). The alert condition overrides, or temporarily disables the screensaver mode if it is set. The alert will stop if the temperature cools below 50°C. Note: This alert message often indicates that there is a problem with proper air flow through the vent holes on both sides of the RS20i chassis. Check that there is nothing obstructing these air vents. Be sure that the fan is spinning (you will feel air blowing out of the RS20i from the fan). If the vents are clear and the fan is spinning, yet the temperature alert does not stop, call your installer for service. RS20i Installation & Operating Guide Document # 9301H52900 Ver. 1.01