Download Worcester DANESMOOR Technical data

Transcript
6. The terminal guard must be evenly spaced about the flue
terminal and secured using screws so that the terminal guard
can be removed for maintenance to the flue terminal..
Fig. 8. Terminal guard Minimum dimensions.
265
7. In certain weather conditions a terminal may steam and
siting where this could cause a nuisance should be avoided.
8. Take care to ensure that combustion products do not enter
ventilated roof voids.
280
Terminal guard.
See 7.4.5.
280
Fig. 7. Flue terminating positions for oil-fired appliances
NOTE: The dimensions given are for general guidance only. Other surrounding buildings or objects may affect the clearance of
combustion products. An alternative flue terminal position should be sought when there is any possibility of a nuisance being
caused by inadequate dispersal of flue products.
Terminals should be positioned so as to avoid products of combustion entering into buildings.
Open
Flue
O
M
N
C.D.
H.J.
Window
E
A
G
B
K
Flue
Terminal
F
F
Minimum Distance (mm)
Open
Low-Level
Flue
Discharge
Terminal Position
A
B
C
D
E
F
G
H
J
K
L
M
N
O
Directly below an opening, air brick, window, etc. ............... Not allowed
600
Horizontally to an opening, air brick, window, etc. .............. Not allowed
600
Below a gutter or sanitary pipe ................................................ Not allowed
75
Below eaves or a balcony.......................................................... Not allowed
600
From vertical sanitary pipework .............................................. Not allowed
75
From an internal or external corner......................................... Not allowed
300
Above ground or balcony level ................................................ Not allowed
300
From a surface facing the terminal .......................................... Not allowed
600
From a terminal facing the terminal ........................................ Not allowed
1200
Vertically from a terminal on the same wall .......................... Not allowed
1500
Horizontally from a terminal on the same wall ..................... Not allowed
300
Above an intersection with the roof ........................................ 600
Not applicable
From a vertical structure on the side of the terminal ........... 600
Not applicable
Above a vertical structure less than 750 mm from the
side of the terminal..................................................................... 600
Not applicable
11
L