Download Worcester DANESMOOR Technical data
Transcript
6. The terminal guard must be evenly spaced about the flue terminal and secured using screws so that the terminal guard can be removed for maintenance to the flue terminal.. Fig. 8. Terminal guard Minimum dimensions. 265 7. In certain weather conditions a terminal may steam and siting where this could cause a nuisance should be avoided. 8. Take care to ensure that combustion products do not enter ventilated roof voids. 280 Terminal guard. See 7.4.5. 280 Fig. 7. Flue terminating positions for oil-fired appliances NOTE: The dimensions given are for general guidance only. Other surrounding buildings or objects may affect the clearance of combustion products. An alternative flue terminal position should be sought when there is any possibility of a nuisance being caused by inadequate dispersal of flue products. Terminals should be positioned so as to avoid products of combustion entering into buildings. Open Flue O M N C.D. H.J. Window E A G B K Flue Terminal F F Minimum Distance (mm) Open Low-Level Flue Discharge Terminal Position A B C D E F G H J K L M N O Directly below an opening, air brick, window, etc. ............... Not allowed 600 Horizontally to an opening, air brick, window, etc. .............. Not allowed 600 Below a gutter or sanitary pipe ................................................ Not allowed 75 Below eaves or a balcony.......................................................... Not allowed 600 From vertical sanitary pipework .............................................. Not allowed 75 From an internal or external corner......................................... Not allowed 300 Above ground or balcony level ................................................ Not allowed 300 From a surface facing the terminal .......................................... Not allowed 600 From a terminal facing the terminal ........................................ Not allowed 1200 Vertically from a terminal on the same wall .......................... Not allowed 1500 Horizontally from a terminal on the same wall ..................... Not allowed 300 Above an intersection with the roof ........................................ 600 Not applicable From a vertical structure on the side of the terminal ........... 600 Not applicable Above a vertical structure less than 750 mm from the side of the terminal..................................................................... 600 Not applicable 11 L