Download Simplicity 400 / 2400 Specifications
Transcript
GE Limitamp® Medium Voltage Motor Control General GE manufactures and provides full support for the following types of medium voltage controllers: Table A.1 Product Scope Controllers Design Layout Construction 1-High 2-High Welded Bolted CR194 Stationary Vacuum 800 amp X X CR194 Drawout Vacuum 800 amp X X CR194 Stationary Vacuum 400 amp X X CR194 Stationary Vacuum 400 amp CR194 Drawout Vacuum 400 amp • Limitamp lineup similar to last three units in the preceding description. The transformer, 480-volt motor controllers, and lighting transformer are included in an integrated Limitamp design. X 480V X X X X Lighting Limitamp control is designed to meet NEMA ICS 3, Part 2 and UL 347 requirements. Various enclosure types and constructions are available and there is a broad selection of modifications for complete control and protection of motors used on modern power-utilization systems with high available short-circuit currents. Applications CR194 Vacuum Limitamp control is a high-interrupting capacity, high-voltage control applied to distribution systems rated 2400, 4160 or 4800 volts (7200-volt starters are available in limited applications.) It is used throughout industry to control and protect squirrel-cage, wound-rotor and synchronous motors. It can also be used to feed transformers and other power-utilization circuits. • Limitamp lineup consisting of a reversing isolating switch ahead of a NEMA Class E2 Limitamp motor controller. • Limitamp lineup consisting of two NEMA Class E2 Limitamp motor controllers, each having interrupting ratings per Table B.1. Typical applications are in paper, steel, cement, rubber, mining, petroleum, chemical and utility-type industries. Limitamp control is also used in water and sewage plants and public buildings for air conditioning, pumps and compressors. Because of its flexibility, other uses for Limitamp equipment have become common. Some of these uses are: • Limitamp lineup consisting of a fused isolating switch ahead of four NEMA Class E2 Limitamp controllers, the first three being used as motor controllers and the last as a transformer feeder. CR194 control is designed for operation on the following power systems. Table A.2 Maximum Motor Hp  Induction, Wound-rotor Synchronous (1.0 PF) Synchronous (0.8 PF) CR194 400 Ampere stationary and drawout 1600 À 2000 À 2400 2800 À 3500 À 4200 3200 À 4800 4000 4800 À 6000 À 7200 CR194 800 Ampere stationary 3200 Á 4000 Á 2400 5600 Á 7000 Á 4200 6400 Á 8000 Á 4800 System Distribution Voltage À Based on 400 amperes RMS maximum, enclosed, NEMA 1, vented one-high Á Based on 800 amperes RMS maximum, enclosed, NEMA 1, vented one-high  For non-vented enclosures, apply a factor of 0.8 to the maximum horsepower A1 A