Download Cooper Security M-Series Programming instructions
Transcript
4. Programming system by pushing an exit terminate button connected to a keypad. Note that the exit time is infinite in this option. Option 2: Final door set. Use this option to complete setting the system by closing a door fitted with a Final Exit zone detector. Note that the exit time is infinite in this option. If a PIR detector covers the final exit door then selecting Final Door Set is not recommended: exit faults may occur if the detector responds to transient drafts caused by the door closing. System Auto Re-Arm (Command 40) This command lets you program the number of times that the system will rearm when the bell delay expires. The system re-arms all closed zones. Select option 0 to make the system never re-arm (the system will go into alarm once only). Select options 1 to 4 to make the system re-arm once, twice, three times or always. Use this command in conjunction with command 35 - First Circuit Response. Bell Delay (Command 41) When the system is set and (for example) an intruder violates a zone, then the system waits for the programmed Bell Delay before operating the external sounder. The system then operates the external sounder for the programmed Bell Duration. See “Programming Commands” for the command options. Bell Duration (Command 42) This command lets you set the length of time the system will operate the external sounder during an alarm. See “Programming Commands” for the command options. Level A Entry Time (Command 43) This command lets you set the Entry Time for Level A (full set). See “Programming Commands” for the command options. The time starts when a user opens any Final Exit zone. Level A Exit Time (Command 44) This command lets you set the Exit Time for Level A (full set). See “Programming Commands” for the command options. Entry/Exit Tone Volume (Command 45) Use this command to set the volume of entry/exit tones from the internal sounder. If you select option 0 then the internal sounder gives no entry/exit tones. If you select option 1 then the internal sounder gives quiet entry/exit tones, while option 9 gives the loudest entry/exit tones. The keypad demon- 496478 43