Download Compaq DS10 Operating instructions
Transcript
3.6 Status Monitoring Use the RMC status command to check the current state of the system’s sensors as well as the current escape sequence and alarm information. RMC> sta PLATFORM STATUS Firmware Revision: V1.1 Power: ON RMC Halt: Deasserted RMC Power Control: ON Power Supply: OK System Fans: OK CPU Fan: OK Temperature: 31.0°C (warnings at 55.0°C, power-off at 60.0°C) Escape Sequence: ^[^[RMC Remote Access: Disabled RMC Password: set Alert Enable: Disabled Alert Pending: YES Init String: AT&F0E0V0S0=2 Dial String: ATXDT8,18007598888 Alert String: ,,,,,,,1066278#,,,,,,,,1#,,,,30140#; Com1_mode: SNOOP Last Alert: AC Loss Watchdog Timer: 00 seconds Autoreboot: OFF Logout Timer: 20 minutes User String: Table 3–2 Status Command Fields Field Firmware Revision Power RMC Halt Meaning Revision of RMC firmware on the microcontroller. On = System is on. Off = System is off. Asserted = System has been halted by RMC. Deasserted = Halt has been released by RMC. Continued on next page. 3-10 DS10 / DS10L Console Reference