Gaia GAIA.ASU.SP.ESM.00007 Issue 2.00 Page 36 of 79 AVI-391/CREATED/T It shall be possible to reset the event counters, individually or all at once, by command from the local MMI or from the CCS (Test Procedure/Command Line).. AVI-390/CREATED/T FCV ON times shall be made available to the RTS for closed-loop testing. AVI-2769/EIU-713, GSE-SYS-761/T It shall be possible to acquire the FCV pulses simultaneously on all channels. 3.6.5.4 CPS Pressure Transducer Simulation AVI-427/EIU-734/T The CPS Pressure Transducer Simulation shall simulate the presence of 4 Pressure Transducers. AVI-463/EIU-735/T CPS Pressure Transducer Simulation shall conform to the requirements of: [AD06] Table 3.5-12 (Analog Driver Specification 3) AVI-432/CREATED/T In open-loop test mode Simulated Pressures shall be commanded asynchronously by local MMI or by the CCS (Test Procedure or Command Line). AVI-1610/CREATED/T In closed-loop test mode Simulated Pressures shall be commanded by the RTS. Astrium Ltd owns the copyright of this document which is supplied in confidence and which shall not be used for any purpose other than that for which it is supplied and shall not in whole or in part be reproduced, copied, or communicated to any person without written permission from the owner. GAIA.ASU.SP.ESM.00007 (Avionics SCOE Req Iss 2).doc