Download Miele Excella G2732SCi Technical information
Transcript
G1000 / G2000 Dishwashers Technical Information 4.2.9 Electronically Controlled Water Hardness (EGS) To prevent or avoid possible glass corrosion, the wash water hardness level should not exceed or fall below 3 gr/gal, in program steps with heating and 5 gr/gal in program steps without heating. With mains water hardness below 20 gr/gal. (In heating steps under 16 gr/gal) the Solenoid Valve Y5 is activated to add a proportion of hard mains water to the cabinet. The proportion added in this way depends on the mains water hardness level set at the electronic unit or that measured at the Sensor Softener. The EGS system is not active as standard in all wash programs, but this can be programmed as an option if required. The EGS Valve is located in the Water Inlet Mixer. 4.2.10 Intelligent Tab Function To optimize wash results, the type of detergent (normal detergent or combination products in tablet form) used in the dishwasher can be set. To adjust the program sequence to suit the detergent type, press the Tab as appropriate. The selected function remains applicable until it is modified again. It is therefore not necessary to select 2 in 1 or 3 in 1 before every program. Standard detergent (powder or tab form): The tab button is not pressed. This means filling rinse aid in the customary way, and salt will be consumed for the reactivation of the water softener. 2 in 1 Detergent: When the 2 in 1 function is selected, the program sequence is adjusted for 2 in 1 tablets (containing detergent and rinse aid). All water intake will be with soft water at the pre-set water hardness level. The dispensing of rinse aid and the rinse aid refill indicator light are deactivated. 3 in 1 Detergent: When 3 in 1 function is selected, the program sequence is adjusted for 3 in 1 tablets (containing detergent, rinse aid and salt). The dispensing of rinse aid and the rinse aid refill indicator light are deactivated. Salt consumption for the softener reactivation is reduced to between 1/3 and ¼ of its normal level. During the first two water intake cycles, prepared water taken from the water softener is added to the circulating water. During the following intake cycle, the softener is inactive. 39