4
Improving Simulation Performance
Figure 4-5: A Circuit Containing Individual Forced Commutated Electronic
Switches Cannot be Discretized
In this circuit, the opening of the GTO forces a quasi instantaneous conduction
of the freewheeling diode. If the circuit was discretized, the diode would be fired
with one step delay, and the inductive current chopping would produce large
overvoltages. However, for conventional converter topologies as in the case of
the Universal Bridge, the switch interactions are known in advance. For
example, in a six-switch IGBT/Diode inverter (Figure 4-6 following), opening of
IGBT1 causes instantaneous conduction of diode D2 in the same arm. As the
circuit topology is predetermined, it is possible to force firing of the diode in the
same step that the IGBT opens. You should use a continuous method if you
prefer to use individual IGBT and Diode blocks to simulate a complete inverter.
4-12