Linear Transformer
Winding 3 parameters
The Winding 3 parameters parameter is not available if the Three
windings transformer parameter is not selected.
The nominal voltage in volts RMS (Vrms), resistance, and leakage
inductance in p.u. The p.u. values are based on the nominal power Pn and
on V3.
Magnetization resistance and reactance
The resistance and inductance simulating the core active and reactive
losses, both in p.u. The p.u. values are based on the nominal power Pn and
on V1. For example, to specify 0.2% of active and reactive core losses, at
nominal voltage, use Rm = 500 p.u. and Lm = 500 p.u.
Measurements
Select Winding voltages to measure the voltage across the winding
terminals of the Linear Transformer block.
Select Winding currents to measure the current flowing through the
windings of the Linear Transformer block.
Select Magnetization current to measure the magnetization current of
the Linear Transformer block.
Select All voltages and currents to measure the winding voltages and
currents plus the magnetization current.
Place a Multimeter block in your model to display the selected
measurements during the simulation.
In the Available Measurements list box of the Multimeter block, the
measurements are identified by a label followed by the block name.
Measurement
Label
Winding voltages
Uw1:, Uw2:, Uw3:
Winding currents
Iw1:, Iw2:, Iw3:
Magnetization current
Imag:
5-121