2.6 Special Function Modules All of the modules that have been discussed thus far have been DISCRETE I/O modules. The inputs or outputs are either ON or OFF. This is acceptable if all the inputs in the PLC system are switches or simple sensors, and the outputs are or lights to turn off and on. If it is necessary to monitor or control a temperature, talk to a network, or control a positioning module, it is necessary to use a Special Function Module (referred to as SFM) to accomplish these tasks. Each of these modules has a range of internal addresses where the data is stored. The PLC has dedicated commands to access this data. Right Side Bus Analog Modules There are 3 types: Analog Input modules, Analog Output modules and Combination Analog Input/Output modules. All are used with I/O points that have more states than just on or off. Examples of analog inputs would be a velocity reading or pressure reading. An example of an analog output would be the variable speed of a motor. The input cards come in 2, 4, or 8 channels. These are the FX2N-2AD, FX2N4AD, and FX2N-8AD. The output cards come in either 2 or 4 channels. These are the FX2N-2DA and FX2N-4DA. There are 2 combination cards. The FX0N3A has 2 input channels and 1 output channel. The FX2N-5A has 4 input channels and 1 output channel. The FX3U family also has two dedicated analog modules, the FX3U-4AD and FX3U-4DA, which are higher resolution and faster processing modules. All are based on varying current or voltage, usually –20 mA to +20 mA, 4-20 mA or –10 to + 10 V, as set by the programmer. Depending on the card, the module receives from the PLC or from the input, a raw number (range varies by module and type, see manuals for ranges), that is interpreted as the analog value read (if an analog input) or the analog value to be sent out (if an analog output) Programming Example The PLC programmer wants to detect small changes in pressure to control a chemical mixing process. He has a sensor that has a range of 0 PSI to 300 PSI and generates a voltage of –10V to +10V, and the FX2N-4AD module, which sees –10V as the number -2000, and +10 V as +2000. Given this information, the programmer knows that at 0 PSI the sensor sends a voltage of –10V, which results in a value of -2000 being written to the PLC. At 150 PSI, 0V is generated, resulting in a value of 0 being written to the PLC. At 300 PSI, the voltage is 10V and the PLC value is 2000. It is the responsibility of the programmer to know what pressure value equates to what PLC value, and to write the program to scale that value accordingly. 14