Download Agilent Technologies 81134A Technical data
Transcript
SOURce Commands SCPI Commands Reference [:SOURce]:VOLTage[0|1|2][:LEVel] [:IMMediate]:LOW Syntax Form Description Parameter Value coupling [:SOUR]:VOLT[0|1|2][:LEV][:IMM]:LOW[?] Set & Query Programs the low- level of the output signal for the trigger output and the channels. Numeric [uV|mV|V] |MIN|MAX Amplitude = High – Low Offset = (High – Low) / 2 Range coupling *RST value High- level Trigger channel (0): 0.0 V Channels 1 and 2: 0.0 V Specified limits Trigger channel (0): –2.0 … +2.95 V Channels 1 and 2: –2.0 … +2.95 V Absolute limits Trigger output (0): –2.2 … +3.2 V Channels 1 and 2: –2.2 … +3.2 V Example Set Channel 1 low- level to –1 V. :VOLT1:LOW -1V Agilent 81133A/81134A Pulse Generator Programming Guide, March 2007 63