Download Simplicity 1600408 Specifications
Transcript
Section S 3F Select Board S.1 Introduction This section describes the 3Frequency select Board. Topics include Function and Location. Parts list for this board is in Section VII. Board # 843 5523 973 Schematic # 843 5523 971 PWA # 992 9764 500 Frequency. LED’s imbedded in the switches tell you what the current Freq is by 3 latching relays. In the event of an AC failure and when AC is restored the last state that the Relays were in will represent the current state. S.3 Location The 3F select board is located on the Left PAC front Door. Next to the Frequency Control Board. See View 24. Refer to Schematic # 843 5523 973 for the following discussion. S.2 Function The 3F select board is used to select 1 of 3 predetermined frequencies. By selecting 1 of the 3 Frequency Pushbuttons a command will then be issued to the 3F controller (described later). Also on this board is the current status of the Transmitters 12/16/03 Frequency 1 Selection. Switch # 1 is a momentary pushbutton switch. When activated a Gnd is sent to the 3F controller. The controller will send a Set command to K1 and a Reset command to K2 and K3. 888-2339-002 WARNING: Disconnect primary power prior to servicing. S-1