Download RIDGID R3121 Technical data

Transcript
Diagnostics
3.1 Diagnostics via LEDs
3.1.1.3
Table 3- 4
Control Unit 320-2DP in operation
Control Unit CU320-2 DP – Description of the LEDs after booting
LED
Color
RDY (READY) -
State
Description, cause
Remedy
OFF
Electronic power supply is missing or outside
permissible tolerance range.
Check power supply
Continuous
light
The component is ready for operation and cyclic
DRIVE-CLiQ communication is taking place.
–
Flashing
light
0.5 Hz
Commissioning / reset
–
Flashing
light
2 Hz
Writing to the memory card
–
Red
Flashing
light
2 Hz
General errors
Check
parameterization/configuratio
n data
Red/
green
Flashing
light
0.5 Hz
Control Unit is ready for operation.
However there are no software licenses.
Obtain licenses
Orange
Flashing
light
0.5 Hz
Updating the firmware of the DRIVE-CLiQ
components
–
Flashing
light
2 Hz
DRIVE-CLiQ component firmware update
complete. Wait for POWER ON for the
components in question.
Turn POWER ON for the
components in question
Flashing
light
2 Hz
Component detection via LED is activated
(p0124[0]).
–
Green
Green /
orange
or
red /
orange
Note:
Both options depend on the LED state when
component detection is activated via
p0124[0] = 1.
Commissioning Manual
Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1