Download 9-4 -1 - Toshiba Air Conditioning
Transcript
Engineering Data Book File No. E06-311 The engineering data book details all relevant data, charts and drawings to enable you to get the best performance from the Toshiba Mini-SMMS for various applications. The information is aimed to assist you by providing greater system details and the wider applications that system covers. It is recommended that the data book be used in accordance with the following as references. Design manual: File No.A06-111 Installation manual: File No.A06-211 Service manual: File No.A05-016 1 -1 Contents 1. Forward ...................................................................................................................... 1-1 2. Contents .................................................................................................................... 2-1 3. Introduction ............................................................................................................... 3-1 4. System overview ....................................................................................................... 4-1 4-1. Summary of system equipments ....................................................................... 4-1 4-2. Outdoor units .................................................................................................... 4-2 4-3. Indoor units ....................................................................................................... 4-3 4-4. Branching joints and headers ........................................................................... 4-5 4-5. PMV Kit ............................................................................................................. 4-5 4-6. Remote controller ............................................................................................. 4-6 5. Capacity compensation chart .................................................................................. 5-1 6. Piping requirements ................................................................................................. 6-1 7. Refrigerant cycle diagram ........................................................................................ 7-1 8. Wiring guideline ........................................................................................................ 8-1 9. Indoor unit line up ..................................................................................................... 9-1 9-1. 4-way Air Discharge Cassette Type ............................................................... 9-1-1 9-2. Compact 4-way Cassette (600 × 600) Type ................................................... 9-2-1 9-3. 2-way Air Discharge Cassette Type ............................................................... 9-3-1 9-4. 1-way Air Discharge Cassette Type (Included NewType) .............................. 9-4-1 9-5. Concealed Duct Standard Type ..................................................................... 9-5-1 9-6. Slim Duct Type ............................................................................................... 9-6-1 9-7. Concealed Duct High Static Pressure Type ................................................... 9-7-1 9-8. Under Ceiling Type ........................................................................................ 9-8-1 9-9. High Wall (1 series) Type ............................................................................... 9-9-1 9-10. High Wall (2 series) Type ............................................................................. 9-10-1 9-11. Floor Standing Cabinet Type ....................................................................... 9-11-1 9-12. Floor Standing Concealed Type .................................................................. 9-12-1 9-13. Floor Standing Type ..................................................................................... 9-13-1 9-14. Optional parts of indoor units ....................................................................... 9-14-1 10. PMV Kit .................................................................................................................... 10-1 11. Outdoor unit ............................................................................................................ 11-1 12. Controls ................................................................................................................... 12-1 2 -1 3 Mini-SMMS Data book Introduction Toshiba MiNi-SMMS Air Conditioning Greater Flexibility for Even More Comfort • Superior new Toshiba VRF system for small and mid-sized buildings • Toshiba’s innovative spirit — concept of VRF, all advantages of SMMS 1 2 World’s best class energy savings • World-class energy savings — COP of 4.61* achieved by Toshiba’s unrivalled SMMS technologies and newly developed components *4HP CDU system Flexible and easy installation • Greater application versatility—13 types of indoor units for use in up to 9 rooms; max. 6 HP 3 4 • Small and light weight outdoor unit • Total piping length 180 m* (forthest 100 m) • Maximum height variation for indoor units (Outdoor unit is up to 30 m higher than indoor unit / outdoor unit is up to 20 m lower than indoor unit) *150 m with PMV kit Pursue unexpected quieter operation • Quiet operation enables a tranquil interior environment, which can be further enhanced with our optional PMV* kit • Product made from quieter outdoor unit by adoption of Bat wing fan *Pulse Motor Valve 5 6 7 8 9 10 11 12 3 -1 3 Introduction 1 World’s best class energy savings World-class energy savings — COP of 4.61* achieved by Toshiba’s unrivalled SMMS technologies and newly developed components *4HP CDU system 2 New New New Vector-controlled inverter Vector IPDU control changes motor current wave to a smooth sinusoidal pattern so that noise emitted from the drive units is greatly reduced. • High output / high efficiency DC motor • 600W output • Sine wave drive 3 4 DC fan motor Efficient circuit built-in and new PIM adoption Heat exchanger Smooth sign curve liquid realizes efficient-izing and low noise-ization. High-efficiency R410A heat-transfer tube Configuration of the finned heat-transfer tube 5 New New 6 Twin-rotary DC compressor Greater motor efficiency from improved coil design Bat wing fan New development for high pressure low sound fan → The bat wing fan realizes the sound level equivalent to current model. 7 Anti-eddy projection Anti-eddy projection prevents big eddies and reduces air resistance. Reverse-arc-shape wing Reverse-arc-shape wing reduces air resistance. 8 9 10 DC twin rotary compressor (A3 comp) features High reliability The enhanced DC twin-rotary compressor delivers stable performance with minimum friction: Ideal for noise-sensitive applications. The outdoor unit is almost imperceptible. TWIN-ROTARY COMPRESSOR Comparison of DC twin rotary and Scroll compressor • Low vibrations • Super-quiet operation • High reliability This difference is the reason for actual energy savings Total efficiency of compressor Toshiba Twin-Rotary Partial load range *Most frequent operation DC Twin rotary type Conventional Scroll type Traditional Compressor Frequency of compressor 3 Nominal range (%) 11 12 Higher refrigerant compression from redesigned compression channels More effective compression from high-precision components -2 (rps) 3 Introduction Expansive variety in our line-up of indoor units Shortest route design by free branching Combination of line and header branching is highly flexible, allowing the shortest route possible thereby saving on installation time and costs. Line/header branching after header branching is only available with TOSHIBA. 2 - Line branching - Header branching - Line + Header branching Line branching after header branching 3 Outdoor unit PMV-Kit 1 Header Br anching joint PMV kit Indoor unit Header branching after header branching 4 Outdoor unit Header Header PMV kit New compact 4-way cassette Indoor unit 6 Small and lightweight Super-MMS outdoor unit Mini-SMMS outdoor unit 228 kg 117 kg 3-phase 1-phase Compact 1,800 mm 7 1,340 mm Mini-SMMS is born from our supreme VRF technology 990 mm 5 900 mm 320 mm 8 750 mm 9 Piping length Best-in-class piping length and height 10 11 12 3 -3 (Revised edition in 7.Apr.2006) 3 Introduction 1 Bat Wing fan Quieter with smoother wind flow New bat wing fan 2 3 Night operation mode 4 5 6 7 8 9 10 Quiet er sound and power saving DC fan motor Mini-SMMS has timed, Night Operation, allowing queter operation at night. (A timer or a switch is local arrangements) Day Clears nighttime residential noise ordinances. Can be used without obstructing peaceful neighborhoods at night. Night Outdoor unit Daytime Night 4HP 49dB 46dB 5HP 50dB 46 dB 6HP 51dB 47dB PMV kit PMV kit (RBM-PMV0361E/RBMPMV0901E) shall be required for quiter place application as an optional to reduce refrigerant sound especially in oil retrieval control or in transient operation as start up. Suppress particular-Hz noise away Suppress overall noise levels Die-away Zone 11 12 (Hz) (Hz) 3 -4 (Revised edition in 7.Apr.2006) 4-1. Summary of system equipments World-class energy savings _COP of 4.61* achieved by Toshiba’s unrivalled S-MMS technologies and newly developed components *4HP CDU system Quiet operation can be further enhanced with an optional PMV (flow regulating valve) Kit. *Pulse Motor Valve Versatile application _13 types of indoor units for use in up to 9 rooms (6 HP) Sales launch scheduled for early 2006. Specifications differ by region. For questions regarding availability, please contact your local distributor. PMV Kit New compact 4-way cassette Use of quieter place Necessity of PMV Kit (RBM-PMV0361E / RBM-PMV0901E) for quieter place application as an optional. 4 -1 4-2. Outdoor units Inverter unit Corresponding HP Model name 4HP 5HP 6HP Heat pump(50Hz) MCY- MAP0401HT MAP0501HT MAP0601HT Heat pump(60Hz) MCY- MAP0401HT2D MAP0501HT2D MAP0601HT2D Cooling capacity(kW)*1 12.1 14.0 15.5 Heating capacity(kW)*1 12.5 16.0 18.0 6 8 9 No.of connectable indoor units *1 Rated conditions o o o Cooling:Indoor air temperature 27 C DB/19 CWB,Outdoor air temperature 35 CDB o o o Heating:Indoor air temperature 20 C DB,Outdoor air temperature 7 CDB/6 CWB Allocation standard of model name MCY- M AP H T 2D No mark: Power supply specification, 1O/ 220-240V, 50Hz 2D : Power supply specification, 1O/ 220V, 60Hz T : Inverter unit H : Heat pump Development Number Capacity rank HP x 10 R410A M : Individual unit Multi Compact Type 4 -2 4-3. Indoor units Type 4-way Air Discharge Cassette Type Compact 4-way Air Discharge (600x600) Type 2-way Air Discharge Cassette Type 1-way Air Discharge Cassette Type Concealed Duct Standard Type Slim Duct Type Concealed Duct High Static Pressure Type Under Ceilling Type Appearance Model name Capacity rank Capacity code Cooling Heating capacity (kW) capacity (kW) PMV Kit MMU-AP0091H 009 type 1.00 2.8 3.2 MMU-AP0121H 012 type 1.25 3.6 4.0 MMU-AP0151H 015 type 1.70 4.5 5.0 MMU-AP0181H 018 type 2.00 5.6 6.3 MMU-AP0241H 024 type 2.50 7.1 8.0 MMU-AP0271H 027 type 3.00 8.0 9.0 MMU-AP0301H 030 type 3.20 9.0 10.0 MMU-AP0361H 036 type 4.00 11.2 12.5 MMU-AP0481H 048 type 5.00 14.0 16.0 MMU-AP0071MH 007 type 0.80 2.2 2.5 Available MMU-AP0091MH 009 type 1.00 2.8 3.2 Available MMU-AP0121MH 012 type 1.25 3.6 4.0 Available MMU-AP0151MH 015 type 1.70 4.5 5.0 Available MMU-AP0181MH 018 type 2.00 5.6 6.3 Available MMU-AP0071WH 007 type 0.80 2.2 2.5 MMU-AP0091WH 009 type 1.00 2.8 3.2 MMU-AP0121WH 012 type 1.25 3.6 4.0 MMU-AP0151WH 015 type 1.70 4.5 5.0 MMU-AP0181WH 018 type 2.00 5.6 6.3 MMU-AP0241WH 024 type 2.50 7.1 8.0 MMU-AP0271WH 027 type 3.00 8.0 9.0 MMU-AP0301WH 030 type 3.20 9.0 10.0 MMU-AP0071YH 007 type 0.80 2.2 2.5 Available MMU-AP0091YH 009 type 1.00 2.8 3.2 Available MMU-AP0121YH 012 type 1.25 3.6 4.0 Available MMU-AP0152SH 015 type 1.70 4.5 5.0 Available MMU-AP0182SH 018 type 2.00 5.6 6.3 Available MMU-AP0242SH 024 type 2.50 7.1 8.0 Available MMD-AP0071BH 007 type 0.80 2.2 2.5 MMD-AP0091BH 009 type 1.00 2.8 3.2 MMD-AP0121BH 012 type 1.25 3.6 4.0 MMD-AP0151BH 015 type 1.70 4.5 5.0 MMD-AP0181BH 018 type 2.00 5.6 6.3 MMD-AP0241BH 024 type 2.50 7.1 8.0 MMD-AP0271BH 027 type 3.00 8.0 9.0 MMD-AP0301BH 030 type 3.20 9.0 10.0 MMD-AP0361BH 036 type 4.00 11.2 12.5 MMD-AP0481BH 048 type 5.00 14.0 16.0 MMD-AP0071SPH 007 type 0.80 2.2 2.5 Available MMD-AP0091SPH 009 type 1.00 2.8 3.2 Available MMD-AP0121SPH 012 type 1.25 3.6 4.0 Available MMD-AP0151SPH 015 type 1.70 4.5 5.0 Available MMD-AP0181SPH 018 type 2.00 5.6 6.3 Available MMD-AP0181H 018 type 2.00 5.6 6.3 MMD-AP0241H 024 type 2.50 7.1 8.0 MMD-AP0271H 027 type 3.00 8.0 9.0 MMD-AP0361H 036 type 4.00 11.2 10.0 MMD-AP0481H 048 type 5.00 14.0 16.0 MMC-AP0151H 015 type 1.70 4.5 5.0 MMC-AP0181H 018 type 2.00 5.6 6.3 MMC-AP0241H 024 type 2.50 7.1 8.0 MMC-AP0271H 027 type 3.00 8.0 9.0 MMC-AP0361H 036 type 4.00 11.2 12.5 MMC-AP0481H 048 type 5.00 14.0 16.0 4 -3 Type Appearance High Wall Type (1 series) High Wall Type (2 series) Floor Standing Cabinet Type Floor Standing Concealed Type Floor Standing Type Cooling Heating capacity (kW) capacity (kW) Capacity rank Capacity code MMK-AP0071H 007 type 0.80 2.2 2.5 Available MMK-AP0091H 009 type 1.00 2.8 3.2 Available MMK-AP0121H 012 type 1.25 3.6 4.0 Available MMK-AP0151H 015 type 1.70 4.5 5.0 Available MMK-AP0181H 018 type 2.00 5.6 6.3 Available MMK-AP0241H 024 type 2.50 7.1 8.0 Available MMK-AP0072H 007 type 0.80 2.2 2.5 Available MMK-AP0092H 009 type 1.00 2.8 3.2 Available MMK-AP0122H 012 type 1.25 3.6 4.0 Available MML-AP0071H 007 type 0.80 2.2 2.5 Available MML-AP0091H 009 type 1.00 2.8 3.2 Available MML-AP0121H 012 type 1.25 3.6 4.0 Available MML-AP0151H 015 type 1.70 4.5 5.0 Available MML-AP0181H 018 type 2.00 5.6 6.3 Available MML-AP0241H 024 type 2.50 7.1 8.0 Available MML-AP0071BH 007 type 0.80 2.2 2.5 MML-AP0091BH 009 type 1.00 2.8 3.2 MML-AP0121BH 012 type 1.25 3.6 4.0 MML-AP0151BH 015 type 1.70 4.5 5.0 MML-AP0181BH 018 type 2.00 5.6 6.3 MML-AP0241BH 024 type 2.50 7.1 8.0 MMF-AP0151H 015 type 1.70 4.5 5.0 MMF-AP0181H 018 type 2.00 5.6 6.3 MMF-AP0241H 024 type 2.50 7.1 8.0 MMF-AP0271H 027 type 3.00 8.0 9.0 MMF-AP0361H 036 type 4.00 11.2 10.0 MMF-AP0481H 048 type 5.00 14.0 16.0 Model name Allocation standard of model name MM - AP H - C : China model M : Compact 4-way Cassete Type W : 2-way Cassete Type S : 1-way Cassete Type Y : Small sized 1-way Cassete Type B : Built-in Type (Built-in Duct Type) (Floor concealed Type) SP(S) : Slim Duct Type Development series No. Based on the cooling capacity (Btu/h)/1,000 R410A U : Cassette Type D : Duct Type C : Under Ceiling Type K : High Wall Type L : Floor Type (Cabinet type) (Concealed type) F : Floor Standing Type MM : Modular Multi Type 4 -4 PMV Kit 4-4. Branching joints and headers Model name *1 Usage RBM-BY53E Indoor unit capacity code (*2) :Total below 6.4 RBM-BY103E Indoor unit capacity code (*2) :Total 6.4 or more and below 7.8 Appearance Y-shape branching joint 4-branching header RBM-HY1043E Indoor unit capacity code (*2) :Total below 7.8 8-branching header RBM-HY1083E Indoor unit capacity code (*2) :Total below 7.8 *1 If total capacity code value of indoor unit exceeds that of outdoor unit, apply code of outdoor unit. *2 "capacity code" can be obtained from page~. (capacity code is not actual capacity) *3 When using Y-shape branching joint for 1st branching, select according to the capacity code of outdoor unit. 4-5. PMV Kit Model name Indoor unit capacity type RBM-PMV0361E 007, 009, 012 type RBM-PMV0901E 015, 018, 024 type For more information see Chapter 10. 4 -5 Appearance 4-6. Remote controller Name Model name Appearance Application Connected to indoor unit Function Start / Stop Mode Change Temperature setting Fan speed Timer function 1 On or off elapsed timer with 30 minite increments. Automatic off function Weekly when combined with RBC-EXW21E2 weekly schedule operation can be operated. RBC-AMT31E Wired remote controller 2 Filter dirty indicator Displays automatically maintenance time of indoor filter by flashes. Self-diagnosis function Wired remote controller Wired remote controller (In case of control by 2 remote controllers) Pressing "CHECK" button displays status code. Control by 2 remote controllers is available. Two remote controllers can be connected to one indoor unit. The indoor unit can be separately operated from a different location. Connected to indoor unit Start / Stop Change of air flow Check code display RBC-AS21E2 Simple wired remote controller Temperature setting TEST SETTING ûC ûF Simple remote controller 4 -6 Model Name name Appearance Function Start / Stop TCB-AX21U(W)-E2 Mode change Temperature setting Change of air flow Timer function On or off timer operation, setting in 30 minute increments. Automatic Off function available. Two wireless remote controllers can RBC-AX22CE2 operate one indoor unit. The indoor unit can be separately operated from a different location. Check code display TCB-AX21U(W)-E2 (for 4-way airdischarge cassette) RBC-AX22CE2 (for under ceiling) TCB-AX21-E2 (for other units except for the concealed duct high static pressure) TCB-AX21E2 Wireless remote controller kit Control by 2 remote controllers is 4 -7 Name Model name Appearance Application Connected to outdoor unit, or indoor unit Outdoor unit Performance Individual control up to 64 indoor units. Individual control for max. 64 indoor units divided into 4 zones. Up to 16 indoor units for each zone Four selectable central control settings to restrict individual remote controller operations. ZONE ALL ZONE GROUP CODE No. TCB-SC642TLE2 Central remote controller Up to 16 outdoor units are connectable. 1234 SET DATA SETTING R.C. UNIT No. TEST Setting for one of 1 to 4 zones is available. No. GROUP SELECT ZONE Central remote controller CL SET Can be used with other central control devices (Up to 10 central control devices with in one control circuit) Two selectable control modes Central controller mode Remote controller mode Setting of simultaneous ON/OFF 3 times for each day of the week combined with a weekly timer. Central remote controller Indoor remote controller Connected to outdoor unit, or indoor unit Individual control up to 16 indoor units. Setting of simultaneous ON-OFF 3 times for each day of the week when combined with a weekly timer. Connected to 2 remote controllers is possible. TCB-CC163TLE2 ON-OFF controller Outdoor unit ON-OFF controller Indoor unit ON-OFF controller Indoor remote controller 4 -8 Name Model name Appearance Application Performance Weekly schedule operation Connected to central remote controller or wired remote controller 1 Setting different start / stop time for each day of the week 2 ON / OFF can be set 3 times a day. ON 8:00 OFF ON OFF ON OFF 12:00 13:00 18:00 19:00 21:00 3 "CHECK" "PROGRAM" "DAY" RBC-EXW21E2 Weekly timer Wired remote controller Weekly timer 4 Two different schedules for a week can be specified. (Summer schedule and winter schedule, etc.) SuMoTuWeTh Fr Sa PROGRAM1 PROGRAM2 button copying of settings easy. ERROR PROGRAM3 5 "CANCEL" "DAY" button enables holiday setting. WEEKLY TIMER 6 If power supply fails, the setting Outdoor unit Central remote controller 4 -9 Weekly timer contents are stored in the memory for 100 hours. 1 For indoor unit, the capacity code is decided for each capacity rank. Capacity rank type 007 009 012 015 018 024 027 030 036 048 Capacity code 0.8 1 1.25 1.7 2 2.5 3 3.2 4 5 NOTE : Capacity rank : Correspondence to Btu/h. Capacity code : Correspondence to Horsepower. 2 For outdoor unit, maximum No. of connectable indoor units and total capacity code of indoor units are decided. Outdoor unit Capacity code of outdoor unit Max. No. of indoor units Total capacity code of indoor units 4 6 3.2 to 5.2 5 8 4.0 to 6.5 6 9 4.8 to 7.8 MCY-MAP0401HT MCY-MAP0401HT2D MCY-MAP0501HT MCY-MAP0501HT2D MCY-MAP0601HT MCY-MAP0601HT2D 5-1. Cooling/heating capacity characteristics 1 Cooling capacity calculation method : Required cooling capacity = Cooling capacity x Factor ( , , 1.1 1.0 0.9 0.8 15 20 24 *1) kW , (Example) Design Indoor conditions : 22oC WB Capacity correction value : 1.09 1.2 Capacity correction value Capacity correction value Indoor air wet bulb temperature vs. capacity correction value , 1.2 1.1 1.0 0.9 0.8 15 20 24 Indoor air wet bulb temp. (oC) o Indoor air wet bulb temp. ( C) 1.2 1.1 1 0.9 -5 0 5 10 15 20 25 30 35 40 43 o Capacity correction value Capacity correction value Outdoor air dry bulb temperature vs.capacity correction value (Example) Design Outdoor conditions : 17oC DB Capacity correction value : 1.14 1.2 1.1 1 0.9 -5 0 5 10 15 20 25 30 35 o 40 43 Outdoor air dry bulb temp. ( C) Outdoor air dry bulb temp. ( C) *1 : Coefficient to use for correction of outdoor unit capacity when total capacity of the indoor units are not equal to the outdoor unit capacity. 5 -1 Capacity correction value Air flow variation ratio of indoor unit vs. capacity correction (For concealed duct type only) 1.1 1.0 0.9 80 90 100 110 120 Air flow variation ratio (%) 82 84 86 88 90 96 98 20 100% Hight of outdoor unit H (m) 30 92 94 Connecting pipe length and lift difference between indoor and outdoor units vs. capacity correction value 10 0 -10 -20 0 10 20 30 40 50 60 70 80 90 100 Pipe length (Equivalent length) L(m) hc hb ha a b c A B Indoor unit 82 84 86 88 90 96 98 H = ho + (Largest one of ha, hb, and hc) 30 20 100% Ll Hight of outdoor unit H (m) ho L is the longest one of (Ll + a, Ll + b, Ll + c) 92 Outdoor unit 94 (Example) Design Pipelength : 55m Height of outdoor unit : 15m Capacity correction value : 89% 10 0 -10 -20 0 10 20 30 40 50 60 70 Pipe length (Equivalent length) L(m) C 5 -2 80 90 100 (Example) Design Outdoor unit : 5.0HP Indoor units total capacity : 5.5HP (Capacity ratio : 110%) Capacity correction value : 1.03% 1.1 1 0.9 Capacity correction value Capacity correction value Correction of outdoor unit diversity 0.8 0.7 80 80 100 110 120 130 1.1 1 0.9 0.8 0.7 80 80 100 Standard capacity ratio Indoor units total capacity ratio (%) 110 120 130 Standard capacity ratio Indoor units total capacity ratio (%) 2 Heating capacity calculation method : Required heating capacity = Heating capacity x Factor ( , , , , *1 , *2) kW (Example) Design Indoor conditions : 21.5oC DB Capacity correction value : 0.98 1.2 Capacity correction value Capacity correction value Indoor air dry bulb temperature vs. capacity correction value 1.1 1.0 0.9 0.8 15 20 24 o Indoor air dry bulb temp. ( C) 1.2 1.1 1.0 0.9 0.8 15 20 24 Indoor air dry bulb temp. (oC) 1.2 (Example) Design Outdoor conditions : -5oC WB Capacity correction value : 0.8 1.1 1 0.9 0.8 0.7 0.6 0.5 -15 -10 -5 0 5 10 15 Outdoor air wet bulb temp. (oC) Capacity correction value Capacity correction value Outdoor air wet bulb temperature vs. capacity correction value 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 -15 -10 -5 0 5 10 Outdoor air wet bulb temp. (oC) *1 : Coefficient to use for correction of outdoor unit capacity when total capacity of the indoor units are not equal to the outdoor unit capacity. *2 : Refer to item 3. 5 -3 15 Capacity correction value Air flow variation ratio of indoor unit vs. capacity correction (For concealed duct type only) 1.1 1.0 0.9 80 90 100 110 120 Air flow variation ratio (%) 94 95 96 97 98 30 99 20 100% Height of outdoor unit H (m) Connecting pipe length and lift difference between indoor and outdoor units vs. capacity correction value 10 0 -10 -20 0 10 20 30 40 50 60 70 80 90 100 Pipe length (Equivalent length) L (m) hc hb ha a b c A B Indoor unit 94 95 97 98 20 99 H = ho + (Largest one of ha, hb, and hc) 30 100% Ll Height of outdoor unit H (m) ho L is the longest one of (Ll + a, Ll + b, Ll + c) 96 (Example) Design Pipe length : 75m Heigh of outdoor unit : 15m Capacity correction value : 95.1% Outdoor unit 10 0 -10 -20 0 10 20 30 40 50 60 70 80 90 Pipe length (Equivalent length) L (m) C 5 -4 100 Correction of outdoor unit diversity Design Outdoor unit : 5HP Indoor units total capacity : 4.5HP (Capacity ratio : 90%) Capacity correction value : 0.9% 1.1 1 0.9 Capacity correction value Capacity correction value (Example) 0.8 0.7 80 90 100 110 120 130 1.1 1 0.9 0.8 0.7 80 Standard capacity ratio Indoor units total capacity ratio (%) 90 100 110 120 130 Standard capacity ratio Indoor units total capacity ratio (%) *1 : Coefficient to use for correction of outdoor unit capacity when total capacity of the indoor units are not equal to the outdoor unit capacity. 3 Capacity correction in case of frost on the outdoor heat exchanger in heating Correct the heating capacity when frost was found on the outdoor heat exchanger. Heating capacity = Capacity after correction of outdoor unit × Correction value of capacity resulted from frost (Capacity after correction of outdoor unit : Heating capacity calculated in the above item 2.) Capacity correction value Capacity correction in case of frost on the outdoor heat exchanger 1.0 0.9 0.8 -15 -10 -5 0 5 10 o Outdoor air wet bulb temp. ( C) 4 Capacity calculation for each indoor unit Capacity for each indoor unit = Capacity after correction of outdoor unit x Required standard capacity of indoor unit Total value of standard indoor unit capacity 5 -5 5 Operating temperature range In cooling time In heating time 45 20 30 25 Continuously operable range 20 15 10 5 0 -5 -10 10 15 20 25 28 30 o Indoor air wet bulb temp. ( C) 15 10 5 Usable range (in warming-up) Outdoor air wet bulb temp. (oC) 35 Usable range (in pull down) Outdoor air dry bulb temp. (oC) 40 0 -5 Continuously operable range -10 -15 -20 5 10 15 20 25 30 Indoor air dry bulb temp. (oC) 6 Rated conditions Cooling : Indoor air temperature 27oC DB/19.0oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 5 -6 6-1. Free branching system Line branching system 2 Header branching system 3 Header branching system after line branching 4 Line branching system after header branching 5 Header branching system after header branching The above five branching systems are available to dramatically increase the flexibility of refrigerant piping design. 1 Outdoor unit Branching joint Line branching system Indoor unit Remote controller Outdoor unit Branching header Header branching system Indoor unit Remote controller * In case of "PMV Kit" Outdoor unit Header branching system after line branching Branching joint Branching header PMV Kit Indoor unit Remote controller * In case of "PMV Kit" Line branching system after header branching Outdoor unit Branching header Header branching system after header branching Branching joint PMV Kit Indoor unit Remote controller 6 -1 6-2. Refrigerant piping length and piping size 1 Allowable length and height difference of refrigerant piping Outdoor unit Main pipe L1 Branching pipe L2 Branching header a 1st branching section b c d Branching pipe L3 Height difference between Indoor and outdoor unit Indoor unit Height difference between indoor units H2 H1 Equivalent length corresponded to farthest piping L Equivalent length corresponded to farthest piping after 1st branching Li L4 e f Y-shape branching joint g A 6 -2 1 Allowable length and height difference of refrigerant piping Total extension of pipe (Liquid pipe, real length) Real length Allowable value Piping section 180m L1+L2+L3+L4+ a+b+c+d+e+f+g 100m Furthest piping length L (*1) L1+L3+L4+g Equivalent length 125m Piping Length Max.equivalent length of main pipe 65m L1 Equivalent length of furthest piping from 1st branching Li (*1) 35m L3+L4+g Max.real length of indoor unit connecting pipe 15m a, b, c, d, e, f, g Upper outdoor unit 30m _ Lower outdoor unit 20m _ 15m _ Height between indoor and outdoor units H1 Height Difference Height between indoor units H2 *1 Furthest indoor unit from 1st branch to be named "A" 6 -3 2 Selection of refrigerant piping Outdoor unit Gas pipe Main pipe Liquid pipe 1st branching Branching section 1 4 2 pipe Branching header 4 3 3 3 3 Indoor unit Branching Y-shape pipe Branching joint 4 2 2 4 3 3 3 Indoor unit 6 -4 2 Selection of refrigerant piping (cont.) No. Piping parts Name Selection of pipe size Size of main pipe Outdoor unit 1 Gas pipe (mm) Liquid pipe (mm) Outdoor unit capacity type 0401 type 15.9 9.5 0501 type 15.9 9.5 0601 type 19.1 9.5 Equivalent to HP Gas pipe (mm) Liquid pipe (mm) Below 2.8 12.7 9.5 2.8 to below 6.4 15.9 9.5 6.4 to below 7.2 19.1 9.5 Main pipe 1st branching section Pipe size between branching sections Total capacity codes of indoor units at down stream side Branching section Branching pipe 2 Branching section Note) If the total capacity code value of indoor units exceeds that of the outdoor units, apply the capacity code of outdoor units. Connecting pipe size of indoor unit Branching section Indoor unit capacity type Indoor unit 3 connecting pipe Indoor unit Gas pipe (mm) Liquid pipe (mm) 007, 009, 012 type 9.5 6.4 015, 018 type 12.7 6.4 024, 030, 036, 048 type 15.9 9.5 Selection of branching section Total capacity codes of indoor units at down stream side Equivalent to HP Y-shape branching joint 4 Branching section Branching header Below 6.4 RBM-BY53E 6.4 to below 7.8 RBM-BY103E For 4 branches Below 7.8 RBM-HY1043E For 8 branches Below 7.8 RBM-HY1083E Y-shape branching joint Branching header Model name Note) *1 : When using a Y-shape branching joint for the 1st branch, select according to capacity code of the outdoor unit. *2 : For 1 line after branching header indoor units with a maximum capacity code of 6.0 in total can be connected. Minimum wall thickness for R410A application Soft Harf Hard or Hard OD (inch) OD (mm) Minimum wall thickness (mm) OK OK 1/4" 6.35 0.80 OK OK 3/8" 9.52 0.80 OK OK 1/2" 12.70 0.80 OK OK 5/8" 15.88 1.00 NG* OK 3/4" 19.05 1.00 6 -5 *If the pipe size is O/ 19.0 or more, use a suitable material. 6-3. Refrigerant piping length and piping size with PMV Kit 1 Allowable length and height difference of refrigerant piping Outdoor unit Main pipe L1 Branching pipe L2 Branching header a 1st branching section b c d PMV Kit Branching pipe L3 h i Height difference between Indoor and outdoor unit j k Indoor unit Height difference between indoor units (PMV Kit) H2 H1 Equivalent length corresponded to farthest piping L Equivalent length corresponded to farthest piping after 1st branching Li L4 e Y-shape Branching joint f l m g n A 6 -6 1 Allowable length and height difference of refrigerant piping Total extension of pipe (Liquid pipe, real length) Real length Allowable value Piping section 150m L1+L2+L3+L4+ a+b+c+d+e+f+g+ h+i+j+k+l+m+n 65m Furthest piping length L (*1) L1+L3+L4+g+n Equivalent length 80m Piping Length Max.equivalent length of main pipe 50m L1 Equivalent length of furthest piping from 1st branching Li (*1) 15m L3+L4+g+n Max.real length of indoor unit connecting pipe 15m a+h, b+i, c+j, d+k, e+l, f+m, g+n Real length between PMV Kit and indoor unit 2m or more and up to 10m h, i, j, k, l, m, n Upper outdoor unit 30m _ Lower outdoor unit 20m _ 15m _ Height between indoor and outdoor unit H1 Height Difference Height between indoor units (PMV Kit) H2 Height difference between highest indoor unit or PMV Kit and lowest indoor unit or PMV Kit shall be 15m or less *1 Furthest indoor unit from 1st branch to be named "A" Not Available PMV Kit Available PMV Kit Indoor unit Indoor unit NOTE , Don t connect two or more indoor units to one PMV Kit. Arrange one indoor unit and one PMV Kit set to 1 by 1. 6 -7 2 Selection of refrigerant piping Outdoor unit Gas pipe Main pipe Liquid pipe 1st branching Branching section 1 4 2 pipe Branching header 4 5 5 3 3 5 3 5 3 Indoor unit Y-shape Branching Branching joint pipe 4 2 2 3 PMV Kit 4 5 3 5 3 Indoor unit 6 -8 5 2 Selection of refrigerant piping (cont.) No. Piping parts Name Selection of pipe size Size of main pipe Outdoor unit 1 Gas pipe (mm) Liquid pipe (mm) Outdoor unit capacity type 0401 type 15.9 9.5 0501 type 15.9 9.5 0601 type 19.1 9.5 Equivalent to HP Gas pipe (mm) Liquid pipe (mm) Below 2.8 12.7 9.5 2.8 to below 6.4 15.9 9.5 6.4 to below 7.2 19.1 9.5 Main pipe 1st branching section Pipe size between branching sections Total capacity codes of indoor units at down stream side Branching section Branching pipe 2 Branching section Note) If the total capacity code value of indoor units exceeds that of the outdoor units, apply the capacity code of outdoor units. Connecting pipe size of indoor unit Branching section Indoor unit capacity type Indoor unit 3 connecting pipe Indoor unit Gas pipe (mm) Liquid pipe (mm) 007, 009, 012 type 9.5 6.4 015, 018 type 12.7 6.4 024 type 15.9 9.5 Selection of branching section Total capacity codes of indoor units at down stream side Equivalent to HP Y-shape branching joint 4 Branching section Branching header Y-shape branching joint *1 Branching For 4 branches header For 8 branches *2 Model name Below 6.4 RBM-BY53E 6.4 to below 7.8 RBM-BY103E Below 7.8 RBM-HY1043E Below 7.8 RBM-HY1083E Note) *1 : When using a Y-shape branching joint for the 1st branch, select according to capacity code of the outdoor unit. *2 : For 1 line after branching header indoor units with a maximum capacity code of 6.0 in total can be connected. Selection of PMV Kit 5 PMV Kit PMV Kit Indoor unit capacity type Model name 007, 009, 012 type RBM-PMV0361E 015, 018, 024 type PBM-PMV0901E Minimum wall thickness for R410A application Soft Harf Hard or Hard OD (inch) OD (mm) Minimum wall thickness (mm) OK OK 1/4" 6.35 0.80 OK OK 3/8" 9.52 0.80 OK OK 1/2" 12.70 0.80 OK OK 5/8" 15.88 1.00 NG* OK 3/4" 19.05 1.00 6 -9 *If the pipe size is O/ 19.0 or more, use a suitable material as detailed in the installation manual. 6-4. Refrigerant piping example 1 In case of without "PMV Kit" Outdoor unit MCY-MAP0601HT Main L1 =60m pipe Branching pipe (7.6) 2 (3.4) Branching header L2 =7m 1st branching section 1 Branching pipe L3 Capacity code a =1m =20m (0.8) b =6m c (1.0) =8m (0.8) d 10m =15m (0.8) MMU-AP0071MH MMU-AP0091H MMU-AP0701MH MMU-AP0701MH Indoor unit (4.2) f =10m e =4m (1.7) Y-shape Branching joint 3 12m (2.5) MMU-AP0151H MMU-AP0241H 6 -10 Piping size Mark Equivalent length (m) L1 60 L2 7 L3 Seclection method (capacity code) Gas pipe (mm) Liquid pipe (mm) O / 19.1 O / 9.5 0.8 + 1.0 + 0.8 + 0.8 = 3.4 O / 15.9 O / 9.5 20 1.7 + 2.5 = 4.2 O / 15.9 O / 9.5 a 1 0.8 O / 9.5 O / 6.4 b 6 1.0 O / 9.5 O / 6.4 c 8 0.8 O / 9.5 O / 6.4 d 15 0.8 O / 9.5 O / 6.4 e 4 1.7 O / 12.7 O / 6.4 f 10 2.5 O / 15.9 O / 9.5 Y-shape branching joint and Header Mark Y-joint or Header select (capacity code) Model name 1 1st branching 6 (capacity code of outdoor unit) RBM-BY53E 2 Branch header 0.8 +1.0 +0.8 +0.8 = 3.4 (a+b+c+d=L2) RBM-HY1043E 3 Y-shape branch joint 1.7 + 2.5 = 4.2 (e+f=L3) RBM-BY53E 6 -11 2 In cace of PMV Kit Outdoor unit MCY-MAP0601HT Main L1 =20m pipe Branching pipe (7.6) 2 (3.4) Branching header L2 =3m 1st branching section 1 Branching pipe L3 Capacity code a =4m =6m (0.8) b =3m c (1.0) =6m d (0.8) 10m =7m (0.8) MMU-AP0071MH MMU-AP0091H MMU-AP0701MH MMU-AP0701MH Indoor unit (4.2) f =6m 12m e =4m (1.7) Y-shape Branching joint 3 (2.5) MMU-AP0151H PMV Kit MMU-AP0241H 6 -12 Piping size Mark Equivalent length (m) L1 20 L2 3 L3 Seclection method (capacity code) Gas pipe (mm) Liquid pipe (mm) O / 19.1 O / 9.5 0.8 + 1.0 + 0.8 + 0.8 = 3.4 O / 15.9 O / 9.5 6 1.7 + 2.5 = 4.2 O / 15.9 O / 9.5 a 4 0.8 O / 9.5 O / 6.4 b 3 1.0 O / 9.5 O / 6.4 c 6 0.8 O / 9.5 O / 6.4 d 7 0.8 O / 9.5 O / 6.4 e 4 1.7 O / 12.7 O / 6.4 f 6 2.5 O / 15.9 O / 9.5 Y-shape branching joint and Header Mark 1 1st branching 2 Branch header 3 Y-shape branch joint Y-joint or Header select (capacity code) Model name 6 (capacity code of outdoor unit) RBM-BY53E 0.8 +1.0 +0.8 +0.8 = 3.4 (a+b+c+d=L2) 1.7 + 2.5 = 4.2 (e+f=L3) RBM-HY1043E RBM-BY53E PMV Kit Mark PMV Kit select (capacity code) Model name 0.8 RBM-PMV0361E 1.0 RBM-PMV0361E 0.8 RBM-PMV0361E 0.8 RBM-PMV0361E 1.7 RBM-PMV0901E 2.5 RBM-PMV0901E 6 -13 6-5. Charging requirement with additional refrigerant After the system has been vacuumed,replace the vacuum pump with a refrigerant cylinder and charge the system with additional refrigerant. R410A Calculating the amount of additional refrigerant required (Calculation) Additional refrigerant charge amount is calculated from size of liquid pipe at site and its real length. Additional refrigerant Real length of R (kg) = charge amount at site liquid pipe Additional refrigerant charge + X amount per liquid pipe 1m (Table 1) Compensation by outdoor HP (Table 2) Table 1 Pipe dia. at liquid side Additional refrigerant amount/1m (kg) O / 6.4 O / 9.5 0.025 0.055 0401 type -0.8 0501 type -0.4 Table 2 Outdoor unit capacity type Compensation by outdoor HP (kg) 0601 type 0 Example : (0501 type) a L1 b O / 9.5 : 10m O / 6.4 : 3m L3 L2 L1 L2 c b O / 9.5 : 10m O / 6.4 : 4m c L3 d d O / 9.5 : 5m a O / 9.5 : 3m O / 6.4 : 5m Additional charge amount R (kg) = (Lx X 0.025kg/m) + (Ly X 0.055kg/m) + (-0.4kg) = (12 X 0.025kg) + (28 X 0.055kg) + (-0.4kg) =1.44kg Lx : Real total length of liquid pipe O / 6.4 (m) Ly : Real total length of liquid pipe O / 9.5 (m) Note) If the additional refrigerant amount indicates a negative result from the calculation, use air conditioner without the adding of any additional refrigerant. 6 -14 7-1. Outdoor unit Sensor (TO) Heat exchanger Strainer Sensor (TE) PMV Strainer Sensor (TL) Capillary tube 2 Solenoid valve (SV5) 4-Way valve Sensor (TS) Check valve Solenoid valve (SV2) Liquid tank Check joint Capillary tube 1 Low-pressure sensor High-pressure sensor Solenoid valve (SV4) High pressure switch Check joint Muffler Sensor (TD) Accumulator Check joint Strainer Compressor (Inverter) Liquid side packed valve Gas side ball valve 7 -1 7-2. Explanation of Functional Parts Functional part name Solenoid valve SV2 SV4 SV5 Capillary tube 1 2 4-Way valve PMV (Pulse motor valve) Temp. sensor TD TS TE TL TO High-ressure sensor Low-pressure sensor Compressor case heater Accumulator case heater Functional outline 1) Low pressure release function 2) High pressure release function 3) Gas balance function during off time 4) Hot gas bypass into accumulator 1) High pressure release function 2) Low pressure release function 1) Preventive function for high-pressure rising in heating operation ID:Ø1.5 Length:200mm ID:Ø2.2 Length:100mm 1) Cooling/heating exchange 2) Reverse defrost 1) Super heat control function in all heating and majority heating operation 2) Sub-cool adjustment function in cooling operation 1) Protection of compressor discharge temp. Used for release 1) Controls super heat in heating operation 1) Controls defrost in heating operation 2) Controls outdoor fan in heating operation 1) Detects under cool in cooling operation 1) Detects outside temperature 1) Detects high pressure and controls compressor capacity 2) Detects high pressure in cooling operation, and controls the fan in low ambientcooling operation 1) Detects low pressure in cooling operation and controls compressor capacity 2) Detects low pressure in heating operation, and controls the super heat 1) Prevents liquid accumulation to compressor 1) Prevents liquid accumulation to accumulator 7 -2 Connector CN312(Whight) CN311(Blue) CN310(Whight) CN317(Blue) CN300(Whight) CN502(Whight) CN504(Whight) CN505(Green) CN521(Whight) CN507(Yellow) CN501(Red) CN500(Whight) CN316(Whight) CN321(Red) 7-3. Indoor Unit Liquid side Gas side Strainer Capillary tube Air heat exchanger at indoor side Pulse Motor Valve (PMV) Strainer Sensor (TCJ) Sensor (TC2) Fan Sensor (TC1) Sensor (TA) M Fan motor (NOTE) MMU-AP0071YH to AP0121YH type air conditioners do not have a TC2 sensor . Functional part name Pulse Motor Valve PMV Temp. sensor Functional outline (Connector CN082 (6P): Blue) 1)Controls super heat in cooling operation 2)Controls under cool in heating operation 3)Recovers refrigerant oil in cooling operation 4)Recovers refrigerant oil in heating operation 1. TA (Connector CN104 (2P): Yellow) 1)Detects indoor suction temperatur e 2. TC1 (Connector CN100 (3P): Brown) 1)Controls PMV super heat in cooling operation 3. TC2 (Connector CN101 (2P): Black) 1)Controls PMV under cool in heating operation 4. TCJ (Connector CN102 (2P): Red) 1)Controls PMV super heat in cooling operation 2) MMU-AP0071 to AP0121YH only Controls PMV under cool in heating operation 7 -3 CAUTIONS (1) Keep the refrigerant piping system and the indoor-indoor/indoor-outdoor control wiring systems together. (2) When running power supplies and control wires parallel to each other, run them through separate conduits or maintain a suitable distance between them. (Current capacity of power supplies: 10A or less for 300m, 50A or less for 500m) 8-1. General Perform wiring of the power supplies in conformance with the regulation of the local electrical company. Use a 2 core shield wire for control wiring on connecting indoor units, and connecting of indoor units to outdoor units. This is recommended to prevent possible noise issues. Be sure to connect an earth leakage breaker to the power supply of the indoor units. Never connect 220-240V power to the control wiring terminal block (U1,U2,U3,U4). Fault will be caused. Locate wiring system for the control and refrigerant piping system in the same line. Arrange the cables so that the electrical wires do not come in to contact with high-temperature parts of the pipework ; otherwise insulation will melt and an accident may be caused. Do not turn on the power supply of the indoor units until vacuuming of the refrigerant pipe has finished. 8-2. Connection of power supply The details are as follows. (Terminal block) (Stripping length power cable) L N 10 10 L N 90 50 Earth line Power cable (Cord clamp) Power cable (Protective bush : Accessory) Power supply specifications Select the power supply cabling and fuse of each outdoor unit from the following specifications: 3 core cable in conformance with Design 60245 IEC 66 Do not connect the units looping via the terminal blocks (L,N) 8 -1 8-3. Electrical wiring desin /%; /#2*6UGTKGU 0` *\8 8 /%;/#2*6&UGTKGU 2QYGTUWRRN[ 0`*\ 8 'CTVJ . Outdoor power source 0 1XGTEWTTGPV DTGCMGT HWUGUYKVEJ Earth leakage Breaker hand switch Over current breaker (fuse) switch 'CTVJNGCMCIGDTGCMGT 1WVFQQTWPKV RQYGT UWRRN[ Pull box Indoor power source Single phase 50Hz 220-240V or 60Hz 220V Earth leakage breaker power switch Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Determine the wire size for the indoor unit according to the number of conncted indoor units downstream. Outdoor Unit capacities and power supply wire sizes (Reference) Observe local regulations in reference to the wire size selection and installtion. Wire size * Outdoor unit capacity type Field fuse 2 0401 type 0501 type 0601 type 6 mm Max. 22 m 6 mm2 Max. 19 m 6 mm2 Max. 17 m 32A 32A 40A * Desi gn 60245 IEC66 For Indoor Unit power supply (Must be independent from the outdoor unit power supply ) Item Power supply wiring Model All models of indoor units Wire size 2.0mm2 MAX.20m Field fuse 3.5mm2 MAX.50m NOTE: The above connecting lengths stated in the table indicate the length from the isolator to the outdoor unit. When the power supply of the indoor units are connected in parallel, it is assumed that no more than a 2% voltage drop will occur. If the connecting length is to exceed the stated lengths, select a suitable wire in accordance with the local wiring standards. 8 -2 (Revised edition in 7.Apr.2006) 15A 8-4. Design of control wiring Power supply Single phase 220-240V 50Hz 220Hz (Open) 60Hz Earth Communication wire for control between outdoor unit and indoor unit Connection of shield wire must be connected (Connected to all connecting sections in each indoor unit) [Central remote controller] (Option) TCB-SC642TLE2 (For line 64) Communication wire for control between indoor and PMV Kit (Follower) (Header) PMV Kit (option) Remote controller Communication wire for control between indoor and PMV Kit (option) Control device Mini-SMMS system U1 U2 U3 U4 A Outdoor unit U3 U4 Outdoor unit Outdoor unit U3 U4 U3 U4 Outdoor unit U1 U2 U1 U2 U1 U2 U1 U2 Indoor unit A B B B B U1 U2 U1 U2 A B Remote controller U1 U2 A B U1 U2 A B U1 U2 A B U1 U2 A B Remote controller U1 U2 A B A B Remote controller Wire specification, quantity, size of crossover wiring and remote controller wiring Name Crossover wiring (A + B) (indoor-indoor / indoor-outdoor / control wiring, central control wiring) *Total Control wiring length Remote controller wiring Control wiring between indoor and PMV Kit Q’ty Up to 500m 1.25mm2 2 cores 2 cores Size Up to 1000m 0.5 to 2.0mm2 - 1000 to 2000m Specification 2.0mm2 Shield wire - - Be sure to use the attached cable. MIN 2m - MAX 10m (1) The crossover wiring and central control wiring uses a 2-core non-polarity communication wire. Use 2-core shielded wire to prevent possible noise issues. Connect the end of the shielded wires and earth(ground) at both the outdoor and indoor unit. Where the shielded wire is connected between a central controller and a outdoor unit, only earth(ground) at one end of the central control line. (2) Use 2-core non-polarity wire for remote controller. (A, B terminals) Use 2-core non-polarity wire for wiring of group control. (A, B terminals) 8 -3 8-5. Example of system wiring Design 1 In cace of without "PMV Kit" Outdoo r pow er supply MCY-MAP###1HT series : 1N~ 50Hz 220V-240V MCY-MAP###1HT2D series : 1N~ 60Hz 220V Outdo or unit Indoor unit Remote contr oller Central r emote contr oller (o ption) Over cur rent b reaker (f use) sw itch Earth leaka ge breaker Main sw itch Pull bo x PMV Kit (opt ion) Centr al remot e contro lle r pow er supply 1N~ 50Hz 220-240V 1N~ 60Hz 220V (Option) L N Earth U1 U2 U3 U4 (Open) (Open) To other refrigerant system [Outdo or un it] L N U1 U2 U3 U4 Earth Relay connector (At shipment from factory : No connection) Connection of shield wire must be connected (Connected to all connecting sections in each Indoor un Control wiring between indoor units [Indoo r unit ] U1 U2 A B control U1 U2 A B Eart h ad U1 U2 A B Eart h L N Earth L N L N Eart h L N A B A B A B Remote cont roller [Grou p cont rol] Indoor unit power supply 1N~ 50Hz 220-240V 1N~ 60Hz 220V 8 -4 U1 U2 A B 2 In cace of "PMV Kit" Outdoo r pow er supply MCY-MAP###1HT series : 1N~ 50Hz 220V-240V MCY-MAP###1HT2D series : 1N~ 60Hz 220V Outdo or unit Indoor unit Remote contr oller Central r emote contr oller (o ption) Over cur rent b reaker (f use) sw itch Earth leaka ge breaker Main sw itch Pull bo x PMV Kit (opt ion) Central remote controlle r power supply 1N~ 50Hz 220-240V 1N~ 60Hz 220V (Option) L N Earth U1 U2 U3 U4 (Open) (Open) To other refrigerant system [Outdo or un it] L N U1 U2 U3 U4 Earth Relay connector (At shipment from factory : No connection) Connection of shield wire must be connected (Connected to all connecting sections in each Indoor un Control wiring between indoor units [Indoo r unit ] U1 U2 A B PMV Kit (option) Indoor control Indoor control PC boad PC boad CN82 U1 U2 A B Eart h U1 U2 A B Eart h L N Earth L N L N Eart h L N A B A B A B Remote cont roller [Grou p cont rol] Indoor unit power supply 1N~ 50Hz 220-240V 1N~ 60Hz 220V 8 -5 U1 U2 A B 8-6. Electrical characteristics 50Hz Outdoor units Model name Nominal (V-Ph-Hz) MCY-MAP0401HT MCY-MAP0501HT MCY-MAP0601HT 230-1-50 230-1-50 230-1-50 Voltage Range Min Max 198 264 198 264 198 264 Legend RLA : Rated Load Amps FLA : Full Load Amps kW : Fan Motor Rated Output (kW) NOTE Compressor Fan Motor RLA kW FLA 0.063 x 2 1.2 22.4 0.063 x 2 1.3 25.3 0.063 x 2 1.3 27.8 Power Supply MCA MOCP ICF 25 32 28 32 31 40 - MCA : Minimum Circuit Amps MOCP : Maximum Overcurrent Protection (Amps) ICF : Maximum Instantaneous Current Flow Start : RLA is based on the following conditions. Indoor temperature : 27oCDB / 19oCWB Outdoor temperature : 35oCDB 50Hz Indoor units Type 4-way Air Discharge Cassette Type Compact 4-way Cassette (600 x 600) Type 2-way Air Discharge Cassette Type 1-way Air Discharge Cassette Type Model MMU-AP 0091 H MMU-AP 0121 H MMU-AP 0151 H MMU-AP 0181 H MMU-AP 0241 H MMU-AP 0271 H MMU-AP 0301 H MMU-AP 0361 H MMU-AP 0481 H MMU-AP 0071 MH MMU-AP 0091 MH MMU-AP 0121 MH MMU-AP 0151 MH MMU-AP 0181 MH MMU-AP 0071 WH MMU-AP 0091 WH MMU-AP 0121 WH MMU-AP 0151 WH MMU-AP 0181 WH MMU-AP 0241 WH MMU-AP 0271 WH MMU-AP 0301 WH MMU-AP 0071 YH MMU-AP 0091 YH MMU-AP 0121 YH MMU-AP 0152 SH MMU-AP 0182 SH MMU-AP 0242 SH Nominal Voltage (V-Ph-Hz) 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 220-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 8 -6 Voltage Range Min Max 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 Fan Motor kW FLA 0.20 0.060 0.20 0.060 0.22 0.060 0.24 0.060 0.28 0.060 0.28 0.060 0.40 0.060 0.68 0.090 0.93 0.090 0.32 0.060 0.35 0.060 0.36 0.060 0.48 0.060 0.48 0.060 0.36 0.053 0.36 0.053 0.36 0.053 0.37 0.039 0.37 0.039 0.53 0.053 0.53 0.053 0.54 0.053 0.28 0.022 0.28 0.022 0.28 0.022 0.40 0.030 0.42 0.030 0.71 0.030 Power Supply MCA MOCP 15 0.25 15 0.25 15 0.28 15 0.30 15 0.35 15 0.35 15 0.50 15 0.85 15 1.16 15 0.40 15 0.44 15 0.45 15 0.60 15 0.60 15 0.45 15 0.45 15 0.45 15 0.46 15 0.46 15 0.66 15 0.66 15 0.68 15 0.35 15 0.35 15 0.35 15 0.49 15 0.53 15 0.88 50Hz Indoor units Type Model MMD-AP 0071 BH MMD-AP 0091 BH MMD-AP 0121 BH MMD-AP 0151 BH MMD-AP 0181 BH MMD-AP 0241 BH MMD-AP 0271 BH MMD-AP 0301 BH MMD-AP 0361 BH MMD-AP 0481 BH MMD-AP 0071 SPH Slim Duct Type MMD-AP 0091 SPH MMD-AP 0121 SPH MMD-AP 0151 SPH MMD-AP 0181 SPH MMD-AP 0181 H Concealed Duct MMD-AP 0241 H High Static MMD-AP 0271 H Pressure Type MMD-AP 0361 H MMD-AP 0481 H MMC-AP 0151 H Under Ceiling Type MMC-AP 0181 H MMC-AP 0241 H MMC-AP 0271 H MMC-AP 0361 H MMC-AP 0481 H MMK-AP 0071 H High Wall 1series MMK-AP 0091 H Type MMK-AP 0121 H MMK-AP 0151 H MMK-AP 0181 H MMK-AP 0241 H MMK-AP 0072 H High Wall 2series MMK-AP 0092 H Type MMK-AP 0122 H MML-AP 0071 H Floor Standing MML-AP 0091 H Cabinet Type MML-AP 0121 H MML-AP 0151 H MML-AP 0181 H MML-AP 0241 H MML-AP 0071 BH Floor Standing MML-AP 0091 BH Concealed Type MML-AP 0121 BH MML-AP 0151 BH MML-AP 0181 BH MML-AP 0241 BH MMF-AP 0151 H Floor Standing MMF-AP 0181 H Type MMF-AP 0241 H MMF-AP 0271 H MMF-AP 0361 H MMF-AP 0481 H Concealed Duct Type Nominal Voltage (V-Ph-Hz) 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 220-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Voltage Range Min Max 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 8 -7 Fan Motor kW FLA 0.33 0.120 0.33 0.120 0.39 0.120 0.39 0.120 0.50 0.120 0.60 0.120 0.60 0.120 0.70 0.120 0.96 0.120 1.13 0.120 0.35 0.060 0.35 0.060 0.37 0.060 0.38 0.060 0.47 0.060 0.93 0.160 1.55 0.160 1.55 0.160 1.87 0.260 2.12 0.260 0.33 0.030 0.37 0.030 0.48 0.040 0.48 0.040 0.90 0.080 0.96 0.080 0.35 0.030 0.35 0.030 0.35 0.030 0.37 0.030 0.37 0.030 0.40 0.030 0.20 0.030 0.21 0.030 0.22 0.030 0.30 0.045 0.30 0.045 0.49 0.045 0.49 0.045 0.54 0.070 0.54 0.070 0.29 0.019 0.29 0.019 0.29 0.019 0.52 0.070 0.52 0.070 0.53 0.070 0.77 0.037 0.77 0.037 1.01 0.063 1.01 0.063 1.48 0.110 1.84 0.160 Power Supply MCA MOCP 15 0.41 15 0.41 15 0.49 15 0.49 15 0.62 15 0.75 15 0.75 15 0.88 15 1.20 15 1.41 15 0.44 15 0.44 15 0.47 15 0.48 15 0.59 15 1.16 15 1.94 15 1.94 15 2.34 15 2.65 15 0.41 15 0.46 15 0.60 15 0.60 15 1.13 15 1.20 15 0.44 15 0.44 15 0.44 15 0.46 15 0.46 15 0.50 15 0.24 15 0.26 15 0.27 15 0.37 15 0.37 15 0.62 15 0.62 15 0.68 15 0.68 15 0.36 15 0.36 15 0.36 15 0.65 15 0.65 15 0.66 15 0.96 15 0.96 15 1.27 15 1.27 15 1.85 15 2.30 8-6. Electrical characteristics 60Hz Outdoor units Model name Nominal (V-Ph-Hz) MCY-MAP0401HT2D MCY-MAP0501HT2D MCY-MAP0601HT2D 220-1-60 220-1-60 220-1-60 Voltage Range Min Max 198 242 198 242 198 242 Legend RLA : Rated Load Amps FLA : Full Load Amps kW : Fan Motor Rated Output (kW) NOTE Compressor Fan Motor RLA kW FLA 0.063 x 2 1.2 22.4 0.063 x 2 1.3 25.3 0.063 x 2 1.3 27.8 Power Supply MCA MOCP ICF 25 32 28 32 31 40 - MCA : Minimum Circuit Amps MOCP : Maximum Overcurrent Protection (Amps) ICF : Maximum Instantaneous Current Flow Start : RLA is based on the following conditions. Indoor temperature : 27oCDB / 19oCWB Outdoor temperature : 35oCDB 60Hz Indoor units Type 4-way Air Discharge Cassette Type Compact 4-way Cassette (600 x 600) Type 2-way Air Discharge Cassette Type 1-way Air Discharge Cassette Type Model MMU-AP 0091 H MMU-AP 0121 H MMU-AP 0151 H MMU-AP 0181 H MMU-AP 0241 H MMU-AP 0271 H MMU-AP 0301 H MMU-AP 0361 H MMU-AP 0481 H MMU-AP 0071 MH MMU-AP 0091 MH MMU-AP 0121 MH MMU-AP 0151 MH MMU-AP 0181 MH MMU-AP 0071 WH MMU-AP 0091 WH MMU-AP 0121 WH MMU-AP 0151 WH MMU-AP 0181 WH MMU-AP 0241 WH MMU-AP 0271 WH MMU-AP 0301 WH MMU-AP 0071 YH MMU-AP 0091 YH MMU-AP 0121 YH MMU-AP 0152 SH MMU-AP 0182 SH MMU-AP 0242 SH Nominal Voltage (V-Ph-Hz) 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 8 -8 Voltage Range Min Max 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 Fan Motor kW FLA 0.21 0.060 0.21 0.060 0.23 0.060 0.25 0.060 0.29 0.060 0.29 0.060 0.42 0.060 0.70 0.090 0.98 0.090 0.31 0.060 0.33 0.060 0.35 0.060 0.47 0.060 0.47 0.060 0.38 0.053 0.38 0.053 0.38 0.053 0.44 0.039 0.44 0.039 0.61 0.053 0.61 0.053 0.67 0.053 0.30 0.022 0.30 0.022 0.30 0.022 0.40 0.030 0.45 0.030 0.75 0.030 Power Supply MCA MOCP 15 0.26 15 0.26 15 0.29 15 0.31 15 0.37 15 0.37 15 0.52 15 0.88 15 1.22 15 0.39 15 0.41 15 0.44 15 0.59 15 0.59 15 0.47 15 0.47 15 0.47 15 0.55 15 0.55 15 0.76 15 0.76 15 0.84 15 0.37 15 0.37 15 0.37 15 0.50 15 0.57 15 0.94 60Hz Indoor units Type Model MMD-AP 0071 BH MMD-AP 0091 BH MMD-AP 0121 BH MMD-AP 0151 BH MMD-AP 0181 BH MMD-AP 0241 BH MMD-AP 0271 BH MMD-AP 0301 BH MMD-AP 0361 BH MMD-AP 0481 BH MMD-AP 0071 SPH Slim Duct Type MMD-AP 0091 SPH MMD-AP 0121 SPH MMD-AP 0151 SPH MMD-AP 0181 SPH MMD-AP 0181 H Concealed Duct MMD-AP 0241 H High Static MMD-AP 0271 H Pressure Type MMD-AP 0361 H MMD-AP 0481 H MMC-AP 0151 H Under Ceiling Type MMC-AP 0181 H MMC-AP 0241 H MMC-AP 0271 H MMC-AP 0361 H MMC-AP 0481 H MMK-AP 0071 H High Wall 1series MMK-AP 0091 H Type MMK-AP 0121 H MMK-AP 0151 H MMK-AP 0181 H MMK-AP 0241 H MMK-AP 0072 H High Wall 2series MMK-AP 0092 H Type MMK-AP 0122 H MML-AP 0071 H Floor Standing MML-AP 0091 H Cabinet Type MML-AP 0121 H MML-AP 0151 H MML-AP 0181 H MML-AP 0241 H MML-AP 0071 BH Floor Standing MML-AP 0091 BH Concealed Type MML-AP 0121 BH MML-AP 0151 BH MML-AP 0181 BH MML-AP 0241 BH MMF-AP 0151 H Floor Standing MMF-AP 0181 H Type MMF-AP 0241 H MMF-AP 0271 H MMF-AP 0361 H MMF-AP 0481 H Concealed Duct Type Nominal Voltage (V-Ph-Hz) 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 Voltage Range Min Max 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 8 -9 Fan Motor kW FLA 0.35 0.120 0.35 0.120 0.41 0.120 0.41 0.120 0.52 0.120 0.63 0.120 0.63 0.120 0.73 0.120 1.00 0.120 1.18 0.120 0.32 0.060 0.32 0.060 0.36 0.060 0.37 0.060 0.44 0.060 1.06 0.160 2.07 0.160 2.07 0.160 2.38 0.260 2.60 0.260 0.35 0.030 0.39 0.030 0.50 0.040 0.50 0.040 0.94 0.080 1.00 0.080 0.37 0.030 0.37 0.030 0.37 0.030 0.39 0.030 0.39 0.030 0.030 0.40 0.030 0.21 0.030 0.22 0.030 0.23 0.045 0.29 0.045 0.29 0.045 0.51 0.045 0.51 0.070 0.61 0.070 0.61 0.019 0.31 0.019 0.31 0.019 0.31 0.070 0.53 0.070 0.53 0.070 0.59 0.037 0.77 0.037 0.77 0.063 1.04 0.063 1.04 0.110 1.58 0.160 2.01 Power Supply MCA MOCP 15 0.43 15 0.43 15 0.51 15 0.51 15 0.65 15 0.78 15 0.78 15 0.91 15 1.25 15 1.48 15 0.41 15 0.41 15 0.45 15 0.47 15 0.56 15 1.32 15 2.59 15 2.59 15 2.98 15 3.25 15 0.43 15 0.48 15 0.63 15 0.63 15 1.18 15 1.25 15 0.46 15 0.46 15 0.46 15 0.48 15 0.48 15 0.50 15 0.26 15 0.27 15 0.29 15 0.36 15 0.36 15 0.63 15 0.63 15 0.76 15 0.76 15 0.39 15 0.39 15 0.39 15 0.66 15 0.66 15 0.73 15 0.96 15 0.96 15 1.29 15 1.29 15 1.97 15 2.52 50Hz 9-1-1. Specifications Specifications (50Hz) Model name MMU- AP0091H AP0121H AP0151H AP0181H AP0241H AP0271H AP0301H AP0361H AP0481H Cooling/Heating capacity (Note 1) (kW) 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 9.0/10.0 11.2/12.5 14.0/16.0 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) Power supply Electrical characteristics 2.8/3.2 Running current (A) 0.17 0.19 0.21 0.24 0.35 0.59 0.81 Power consumption (kW) 0.020 0.022 0.026 0.032 0.048 0.070 0.110 Starting current (A) 0.30 0.33 0.36 0.42 0.59 0.87 1.23 Heat-insulating material attached Zinc hot dipping steel plate Main unit Appearance Ceiling panel RBC-U21PG (W)-E Model Moon white (Munsell/2.5GY 9.0/0.5) Panel color 256 Height (mm) Main unit Outer dimension Ceiling panel 319 Width (mm) 840 Depth (mm) 840 Height (mm) 35 Width (mm) 950 Depth (mm) 950 Main unit (kg) Ceiling panel (kg) 20 22 23 28 Total weigh 4.5 Finned tube Heat exchanger Soundproof/Heat-insulating material Non-flammable insulation Turbo fan Fan Fan unit Standard air flow (High/Mid/Low) Motor (m3/h) 800 (730/680) 930 1,050 (830/790) (920/800) 1,320 1,680 2,040 (1,110/850) (1,300/1,070) (1,430/1,130) 60 (W) 90 Standard filter (Long life filter) Air filter Remote controller Controller Connecting pipe 1,200 (920/820) Gas side (mm) Liquid side (mm) O / 9.5 O / 15.9 O / 6.4 Drain port (Nominal dia. mm) Sound pressure level (Note 2) (dB(A)) (High/Mid/Low) O / 12.7 O / 9.5 25 (Polyvinyl chloride tube) 30/29/27 31/29/27 32/29/28 PMV Kit 34/31/28 37/33/30 40/36/33 44/38/34 Not available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-1 -1 60Hz Specifications (60Hz) Model name MMU- AP0091H AP0121H AP0151H AP0181H AP0241H AP0271H AP0301H AP0361H AP0481H (kW) 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 9.0/10.0 11.2/12.5 14.0/16.0 Cooling/Heating capacity (Note 1) Power supply 1 phase 60Hz 220V (Separate power supply for indoor units is required.) (A) Running current Electrical characteristics Power consumption (kW) Starting current (A) 0.18 0.20 0.22 0.26 0.37 0.61 0.85 0.020 0.022 0.026 0.032 0.048 0.070 0.110 0.30 0.33 0.36 0.42 0.59 0.87 1.23 Main unit Heat-insulating material attached Zinc hot dipping steel plate RBC-U21PG (W) -E Model Appearance Ceiling panel Main unit Outer dimension Ceiling panel Panel color Moon white (Munsell/2.5GY 9.0/0.5) Height (mm) Width (mm) 840 Depth (mm) 840 Height (mm) 35 Width (mm) 950 Depth (mm) 950 Main unit (kg) Ceiling panel (kg) 256 319 22 20 23 28 Total weight 4.5 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Turbo fan Fan Fan unit Standard air flow (High/Mid./Low) Motor (m3/h) 800 (730/680) 930 (830/790) 1,050 (920/800) (W) 1,200 (920/820) 1,320 (1,110/850) 1,680 (1,300/1,070) 60 Air filter 2,040 (1,430/1,130) 90 Standard filter (Long life filter) Controller Remote controller Gas side Connecting Liquid side pipe (mm) O / 9.5 (mm) O / 15.9 O / 12.7 O / 9.5 O / 6.4 Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid./Low) (dB(A)) 25 (Polyvinyl chloride tube) 30/29/27 31/29/27 32/29/28 PMV Kit 34/31/28 37/33/30 40/36/33 44/38/34 Not available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 9-1 -2 O O O 9-1-2. Dimension MMU-AP0091H to P0481H Suction grille (Air suction port) Electric parts box Air discharge port (4-way) 35 860 to 910 ceiling open dimension 254.5 346.5 790 hanging bolt pitch 950 panel external dimension 415 o 381.6 723 hanging bolt pitch Z 860 to 910 ceiling open dimension 950 panel external dimension For branch duct knockout square hole O / 150 (2 positions at right side) Refrigerant pipe connecting port 840 (Gas) 250 70 Refrigerant pipe Drain discharge port 270 connecting port 105 (Liquid) Bottom face of ceiling 45 113 174 30 Bottom face of ceiling Model AP0091H to AP0301H AP0361H to AP0481H Bottom face of ceiling 15 or more Bottom face of ceiling (NOTE) As ABS is used for the drain discharge port of the main unit, the vinyl chloride paste cannot be used. Use the flexible hose (Band fix) included in the package. Knockout for flesh air intake For O / 100 Z view Drain-up standing-up size 2.7 Wired remote controller 4 RBC-AMT31E 1000 or more A 256 319 mm B 120 183 1000 or more 1000 or more Indoor unit 64 Stand-up 850 or less 57 .5 57 5 2 8 18 Stand-up 640 or less 360 15 or more 88 130 210 A 97 B 35 840 480 227 105 Hanging bolt M10 or W3/8 local arrange Space required for installation and servicing 200 Wireless remote controller kit TCB-AX21U(W)-E2 16 Weekly timer application 120 RBC-AMT31E and RBC-EXW21E2 Check port ( 450) Check port ( 450) 200 120 Simple wired remote controller RBC-AS21E2 Note: All dimensions are in mm. 9-1 -3 9-1 -4 1 1 2 2 3 3 1 1 BLK 3 3 CN44 1 (BLN) 2 CN66 1 (WHI) 2 WHI CN67 (BLK) 2 2 RED 1 CN304 (GRY) 2 3 : BLACK : GRAY : PINK : ORANGE : GREEN Parts name BLK GRY PNK ORN GRN Fan motor Indoor temp sensor Temp sensor Temp sensor Temp sensor Lover motor Drain pump motor Float switch Drain control relay Pulse Motor Valve : RED : WHITE : YELLOW : BLUE : BROWN Color identification RED WHI YEL BLU BRN Symbol FM TA TC1 TCJ TC2 LM1, LM2 DM FS RY302 PMV R(L) S(N) Closed end connector RED WHI Power supply Single phase 220-240V 50Hz 220V 60Hz Earth screw Indoor unit Flow selector unit earth screw DM CN68 (BLU) Ð + CN61 (YEL) T10 1 2 3 4 5 6 CN60 (WHI) Power supply circuit Outdoor unit U1 U2 (Option) 3. indicates the control P.C. board. CN81 (BLK) Wired remote controller 1 2 1 2 CN1 (WHI) BLK A B 1 2 3 4 5 WHI 1 2 3 4 5 CN33 1 2 3 4 5 (WHI) BLK 1 2 1 2 CN001 (WHI) Adaptor for wireless remote controller WHI WHI BLK 1 2 3 1 2 3 CN41 (BLU) 1 2 1 2 CN40 (BLU) TR CN02 (BLU) 3 3 2 2 1 1 1 1 2 2 CN101 (BLK) CN73 (RED) CN80 (GRN) 1 2 3 4 5 MCC-1401 X Y TA 1 Filter input 2 TC1 TC2 TCJ 1 EXCT 2 1 2 PNL 3 1 1 2 2 3 3 1 1 2 2 CN102 (RED) CN100 (BRN) 1 1 2 2 CN104 (YEL) CN20 CN70 (BLU) (WHI) 1 2 CN03 1 2 (RED) Network adaptor P.C. board FS 3 1 CN34 3 2 1 (RED) CN01 1 2 Network adaptor (WHI) 1 2 (Option) 1 2 3 1 2 3 CN309 (YEL) Indoor control P.C. board MCC-1402 DC20V DC15V DC12V DC7V U1 U2 1 2 3 4 5 6 Fuse T3.15A 250V~ indicates the terminal block, the letter inside indicates the terminal number. (Fandrive) 1 2 CN32 (WHI) ~ ~ Motor drive circuit 1 2 3 4 5 6 CN82 1 2 3 4 5 6 (BLU) 2 . A dotted line and broken line indicate the wiring on site. 1. 1 2 3 4 5 CN50 (WHI) P301 Fuse T6.3A 250V~ RY303 RY302 5 4 3 2 1 CN334 1 2 3 4 5 CN333 5 4 3 2 1 (BLU) 1 2 3 4 5 (WHI) 6 4 3 1 2 5 6 4 3 1 2 5 LM1 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 LM2 1 2 3 4 5 1 2 3 4 5 BLU BLU BLK PMV BLK FM 9-1-3. Wiring diagram Model:MMU-AP0091H, AP0121H, AP0151H, AP0181H, AP0241H, MMU-AP0271H, AP0301H, AP0361H, AP0481H, AP0561H 9-1-4. Sensible capacity table (MMU-AP***H) Cooling capacity Unit size 009 012 015 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 1.9 2.4 1.9 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.2 2.3 3.1 2.2 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.0 3.0 3.9 2.8 18.0°CWB 26°CDB TC SHC 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.6 2.0 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.4 2.5 3.4 2.4 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.3 3.1 4.2 3.0 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0°CWB 20.0°CWB 22.0°CWB 24.0°CWB 27°CDB 28°CDB 30°CDB 32°CDB TC SHC TC SHC TC SHC TC SHC 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.7 2.1 2.8 2.1 3.0 2.0 3.1 2.0 2.7 2.0 2.8 2.0 2.9 2.0 3.1 1.9 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.4 3.8 2.4 4.0 2.4 3.5 2.4 3.6 2.4 3.8 2.3 3.9 2.3 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.4 3.1 4.5 3.1 4.8 3.1 5.0 3.0 4.3 3.0 4.4 3.0 4.7 3.0 4.9 2.9 9-1 -5 Cooling capacity (cont.) Unit size 018 024 027 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.0 3.6 4.9 3.5 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.3 4.5 6.2 4.4 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.1 5.1 7.0 4.9 18.0°CWB 26°CDB TC SHC 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.3 3.8 5.2 3.7 6.9 4.9 6.9 4.9 6.9 4.9 6.9 4.9 6.9 4.9 6.9 4.9 6.9 4.9 6.9 4.9 6.9 4.9 6.9 4.9 6.9 4.9 6.9 4.9 6.9 4.9 6.9 4.9 6.7 4.8 6.6 4.6 7.8 5.5 7.8 5.5 7.8 5.5 7.8 5.5 7.8 5.5 7.8 5.5 7.8 5.5 7.8 5.5 7.8 5.5 7.8 5.5 7.8 5.5 7.8 5.5 7.8 5.5 7.8 5.5 7.6 5.4 7.4 5.2 Indoor air temp. 19.0°CWB 27°CDB TC SHC 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.5 3.8 5.4 3.7 7.1 4.9 7.1 4.9 7.1 4.9 7.1 4.9 7.1 4.9 7.1 4.9 7.1 4.9 7.1 4.9 7.1 4.9 7.1 4.9 7.1 4.9 7.1 4.9 7.1 4.9 7.1 4.9 7.0 4.8 6.8 4.6 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 8.0 5.5 7.8 5.4 7.7 5.2 20.0°CWB 28°CDB TC SHC 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.7 3.8 5.5 3.7 7.3 4.9 7.3 4.9 7.3 4.9 7.3 4.9 7.3 4.9 7.3 4.9 7.3 4.9 7.3 4.9 7.3 4.9 7.3 4.9 7.3 4.9 7.3 4.9 7.3 4.9 7.3 4.9 7.2 4.8 7.0 4.6 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.1 5.4 7.9 5.2 9-1 -6 22.0°CWB 30°CDB TC SHC 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.0 3.8 5.9 3.6 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.6 4.8 7.4 4.6 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.5 5.3 8.4 5.1 24.0°CWB 32°CDB TC SHC 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.3 3.7 6.1 3.6 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 7.9 4.6 7.8 4.5 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 8.9 5.2 8.8 5.0 Cooling capacity (cont.) Unit size 030 036 048 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.0 5.7 7.8 5.5 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.0 7.1 9.8 6.8 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.5 9.1 12.2 8.7 18.0°CWB 26°CDB TC SHC 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.6 6.1 8.4 5.9 10.9 7.7 10.9 7.7 10.9 7.7 10.9 7.7 10.9 7.7 10.9 7.7 10.9 7.7 10.9 7.7 10.9 7.7 10.9 7.7 10.9 7.7 10.9 7.7 10.9 7.7 10.9 7.7 10.6 7.6 10.4 7.3 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.3 9.6 13.0 9.2 Indoor air temp. 19.0°CWB 27°CDB TC SHC 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 8.8 6.1 8.6 5.8 11.2 7.7 11.2 7.7 11.2 7.7 11.2 7.7 11.2 7.7 11.2 7.7 11.2 7.7 11.2 7.7 11.2 7.7 11.2 7.7 11.2 7.7 11.2 7.7 11.2 7.7 11.2 7.7 11.0 7.5 10.8 7.2 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 13.7 9.6 13.4 9.2 20.0°CWB 28°CDB TC SHC 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.1 6.1 8.9 5.8 11.5 7.7 11.5 7.7 11.5 7.7 11.5 7.7 11.5 7.7 11.5 7.7 11.5 7.7 11.5 7.7 11.5 7.7 11.5 7.7 11.5 7.7 11.5 7.7 11.5 7.7 11.5 7.7 11.3 7.5 11.1 7.2 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.1 9.6 13.8 9.2 9-1 -7 22.0°CWB 30°CDB TC SHC 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.6 6.0 9.4 5.8 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.0 7.5 11.7 7.2 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.0 9.5 14.6 9.1 24.0°CWB 32°CDB TC SHC 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.1 5.9 9.8 5.6 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.5 7.3 12.3 7.0 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 15.6 9.3 15.3 8.9 Heating capacity Unit size 009 012 015 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 2.0 2.1 2.3 2.3 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.3 3.3 3.3 3.3 2.5 2.7 2.8 2.9 3.1 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.2 4.2 4.2 4.2 3.1 3.3 3.6 3.7 3.9 4.1 4.3 4.5 4.7 4.8 5.0 5.2 5.2 5.2 5.2 5.2 SHC : Sensible Heat Capacity (kW) Indoor air temp. °CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 2.0 1.9 1.9 1.8 2.1 2.1 2.0 1.9 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.1 2.4 2.4 2.3 2.3 2.6 2.5 2.4 2.4 2.7 2.6 2.6 2.5 2.8 2.7 2.7 2.6 2.9 2.9 2.8 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 2.9 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 2.5 2.4 2.3 2.3 2.6 2.6 2.5 2.4 2.8 2.7 2.7 2.6 2.9 2.8 2.7 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 3.0 3.3 3.3 3.2 3.1 3.5 3.4 3.3 3.3 3.7 3.6 3.5 3.4 3.8 3.7 3.6 3.5 3.9 3.9 3.8 3.7 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 3.1 3.0 2.9 2.9 3.3 3.2 3.1 3.0 3.5 3.4 3.3 3.2 3.6 3.5 3.4 3.3 3.8 3.7 3.6 3.5 4.0 3.9 3.8 3.7 4.2 4.1 4.0 3.9 4.4 4.3 4.2 4.1 4.6 4.5 4.4 4.2 4.7 4.6 4.5 4.4 4.9 4.8 4.7 4.6 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 9-1 -8 Heating capacity (cont.) Unit size 018 024 027 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 5.0 5.3 5.7 5.8 6.2 6.5 6.8 7.1 7.4 7.7 8.0 8.3 8.3 8.3 8.3 8.3 5.6 6.0 6.4 6.6 7.0 7.3 7.7 8.0 8.4 8.7 9.0 9.4 9.4 9.4 9.4 9.4 Indoor air temp. °CDB 18.0 20.0 22.0 SHC SHC SHC 3.9 3.8 3.7 4.1 4.0 3.9 4.4 4.3 4.2 4.5 4.4 4.3 4.8 4.7 4.6 5.0 4.9 4.8 5.3 5.2 5.0 5.5 5.4 5.3 5.8 5.6 5.5 6.0 5.9 5.7 6.2 6.1 5.9 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 4.9 4.8 4.7 5.2 5.1 5.0 5.6 5.5 5.3 5.7 5.6 5.5 6.1 5.9 5.8 6.4 6.2 6.1 6.7 6.6 6.4 7.0 6.9 6.7 7.3 7.1 7.0 7.6 7.4 7.3 7.9 7.7 7.5 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 5.5 5.4 5.3 5.9 5.8 5.6 6.3 6.1 6.0 6.5 6.3 6.2 6.8 6.7 6.5 7.2 7.0 6.9 7.5 7.4 7.2 7.9 7.7 7.5 8.2 8.0 7.8 8.5 8.4 8.2 8.9 8.7 8.5 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 24.0 SHC 3.6 3.8 4.1 4.2 4.4 4.7 4.9 5.1 5.3 5.6 5.8 6.0 6.0 6.0 6.0 6.0 4.6 4.9 5.2 5.3 5.6 5.9 6.2 6.5 6.8 7.1 7.3 7.6 7.6 7.6 7.6 7.6 5.1 5.5 5.8 6.0 6.3 6.7 7.0 7.3 7.6 7.9 8.3 8.6 8.6 8.6 8.6 8.6 9-1 -9 Heating capacity (cont.) Unit size 030 036 048 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 6.3 6.7 7.1 7.3 7.7 8.1 8.5 8.9 9.3 9.7 10.0 10.4 10.4 10.4 10.4 10.4 7.8 8.3 8.9 9.1 9.7 10.2 10.7 11.1 11.6 12.1 12.6 13.0 13.0 13.0 13.0 13.0 10.0 10.7 11.4 11.7 12.4 13.0 13.6 14.3 14.9 15.5 16.1 16.7 16.7 16.7 16.7 16.7 Indoor air temp. °CDB 18.0 20.0 22.0 SHC SHC SHC 6.1 6.0 5.9 6.6 6.4 6.3 7.0 6.8 6.7 7.2 7.0 6.9 7.6 7.4 7.2 8.0 7.8 7.6 8.4 8.2 8.0 8.8 8.6 8.4 9.1 8.9 8.7 9.5 9.3 9.1 9.9 9.7 9.4 10.2 10.0 9.8 10.2 10.0 9.8 10.2 10.0 9.8 10.2 10.0 9.8 10.2 10.0 9.8 7.7 7.5 7.3 8.2 8.0 7.8 8.7 8.5 8.3 9.0 8.8 8.6 9.5 9.3 9.1 10.0 9.8 9.5 10.5 10.2 10.0 10.9 10.7 10.5 11.4 11.2 10.9 11.9 11.6 11.3 12.3 12.1 11.8 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 9.8 9.6 9.4 10.5 10.3 10.0 11.1 10.9 10.7 11.5 11.2 11.0 12.1 11.9 11.6 12.8 12.5 12.2 13.4 13.1 12.8 14.0 13.7 13.4 14.6 14.3 14.0 15.2 14.9 14.5 15.8 15.4 15.1 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 24.0 SHC 5.7 6.1 6.5 6.7 7.0 7.4 7.8 8.1 8.5 8.8 9.2 9.5 9.5 9.5 9.5 9.5 7.2 7.6 8.1 8.3 8.8 9.3 9.7 10.2 10.6 11.0 11.5 11.9 11.9 11.9 11.9 11.9 9.1 9.7 10.4 10.7 11.3 11.9 12.4 13.0 13.6 14.1 14.7 15.2 15.2 15.2 15.2 15.2 9-1 -10 9-1-5. Air throw distance chart MMU-AP0091H, AP0121H MMU-AP0151H 2.8m 2.7m 0.7m/s 2 0.3m/s 2 0.5m/s 0.5m/s 0.7m/s 1 1 0.3m/s 0 0 1 2 3 4 1 2 3 4 5m 5m MMU-AP0181H MMU-AP0241H,AP0271H 3.6m 3 2.8m 0.7m/s 2 0.7m/s 1 1 2 3 4 0.3m/s 1 0.3m/s 0 0.5m/s 2 0.5m/s 0 5m 1 2 3 4 5m MMU-AP0301H MMU-A0361H 3.6m 3 3.6m 2 0.7m/s 3 0.7m/s 0.5m/s 2 0.5m/s 0.3m/s 1 1 0.3m/s 0 0 1 2 3 4 1 2 3 4 5m 5m MMU-AP0561H 3.6m 3 MMU-A0481H 0.7m/s 3.6m 3 0.3m/s 0.5m/s 2 1 0.3m/s 1 0 0.5m/s 2 0.7m/s 1 2 3 4 5m 0 9-1 -11 1 2 3 4 5m 9-1-6. Sound characteristics (NC-Curve) Sound level values shown are based on a measurement in a non resound room. Microphone Octave band sound pressure level (dB) MMU-AP0091H, AP0121H Fan Tap H M L Sound pressure level (dB(A)) 30 29 27 Audibility limits of continuous white level Octave band frequency (Hz) MMU-AP0181H Fan Tap H M L Fan Tap H M L Sound pressure level (dB(A)) 31 29 27 Sound pressure level (dB(A)) 32 29 28 Octave band sound pressure level (dB) Octave band sound pressure level (dB) MMU-AP0151H Audibility limits of continuous white level Octave band frequency (Hz) Octave band frequency (Hz) Octave band sound pressure level (dB) MMU-AP0241H, AP0271H Fan Tap H M L Sound pressure level (dB(A)) 34 31 28 Audibility limits of continuous white level Audibility limits of continuous white level Octave band frequency (Hz) 9-1 -12 Sound level values shown are based on a measurement in a non resound room. MMU-AP0301H 37 M 33 L 30 Octave band sound pressure level (dB) Sound pressure level (dB(A)) Octave band sound pressure level (dB) MMU-AP0361H H Fan T ap Tap Audibility limits of continuous white level Fan T ap Tap H M L Sound pressure level (dB(A)) 40 36 33 Audibility limits of continuous white level Octave band frequency (Hz) MMU-AP0481H Octave band frequency (Hz) MMU-AP0561H M L Fan T ap Tap H M L Sound pressure level (dB(A)) 44 38 34 Sound pressure level (dB(A)) 45 48 34 Audibility limits of continuous white level Octave band sound pressure level (dB) H Octave band sound pressure level (dB) Fan T ap Tap Audibility limits of continuous white level Octave band frequency (Hz) Octave band frequency (Hz) 9-1 -13 9-1-7. Accessories Apperarance Standard accessories Part name Qty Shape Use Part name Qty Shape Use Installation Manual 2 (Be sure to hand over to customer) Heat insulator 1 For heat insulating of drain connecting section Heat insulating pipe 2 For heat insulating of pipe connecting section Washer 8 For hanging down unit Installation pattern 1 For confirmation of ceiling opening and main unit position Hose band 1 For connecting drain pipe Installation gauge 2 For positioning of ceiling position (united with installation pattern) Flexible hose 1 For centering the drain pipe Pattern fixing screw 4 For attaching pattern Heat insulator 1 For sealing the wire connection opening M5 x 16 Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller Wireless remote controller kit RBC-AS21E2 TCB-AX21U(W)-E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-1 -14 Optional accessories Air discharge direction kit Auxiliary fresh air Flange TCB-FF101URE2 Super Long Life Filter TCB-LF1601UE2 TCB-BC1601UE High Efficiency Filter 65 TCB-UFM1601UE High Efficiency Filter 90 TCB-UFH1601UE Fresh air inlet Box Fresh air and Filter Chamber TCB-GB1601UE2 TCB-GFC1601UE2 Spacer for height adjustment TCB-SP1601UE Ceiling panel RBC-U21PG(W)-E2 Name Model name Note Ceiling panel RBC-U21PG(W)-E2 Super Long Life Filter TCB-LF1601UE2 Dust collecting effect :50% (Weight method) Use with TCB-GFC1601UE2 High Efficiency Filter 65 TCB-UFM1601UE Dust collecting effect :65% (NBS Colorimentric method) Use with TCB-GFC1601UE2 High Efficiency Filter 90 TCB-UFH1601UE Dust collecting effect :90% (NBS Colorimentric method) Use with TCB-GFC1601UE2 Fresh Air Inlet Box TCB-GB1601UE2 For fresh air intake by using the knockout hole of fresh air and filter chamber. (dia=100mm) *Not valid in combination with TCB-FF101URE Use with TCB-GFC1601UE2 Frech Air and Filter Chamber TCB-GFC1601UE2 For fresh air intake and installing high efficiency filter or super long filter Auxiliary Fresh Air Flange TCB-FF101URE2 For easy fresh air intake by using the knockout hole of indoor unit.(dia=100mm) *Not valid in combination with TCB-GB1601UE2 Spacer for Height Adjustment TCB-SP1601UE Height=500mm Air Discharge Direction Kit TCB-BC1601UE Air direction charge by cutting off air discharge port (3pcs) Required accessory 9-1 -15 9-2-1. Specifications 50Hz Specifications (50Hz) Model name Cooling/Heating capacity (Note 1) MMU- AP0071MH AP0091MH AP0121MH AP0151MH AP0181MH (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 Power supply Electrical characteristics 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) (A) 0.28 0.30 0.31 0.34 0.42 Power consumption (kW) 0.034 0.036 0.038 0.041 0.052 Starting current 0.49 0.52 0.54 0.59 0.73 Running current (A) Main unit Appearance Ceiling panel Zinc hot dipping steel plate *Heat-insulating material attached to only upper plate Model RBC-UM11PG(W)E Panel color Moon white (Munsell/2.5GY 9.0/0.5) Height (mm) 268 Width (mm) 575 Depth (mm) 575 Height (mm) 27 Width (mm) 700 Depth (mm) 700 Main unit (kg) 17 Ceiling panel (kg) 3 Main unit Outer dimension Ceiling panel Total weigh Finned tube Heat exchanger Soundproof/Heat-insulating material Non-flammble insulation Turbo fan Fan Fan unit Standard air flow (High/Mid/Low) Motor (m3/h) 552/462/378 570/468/378 594/504/402 Long life filter Controller RBC-AMT31E Gas side O / 9.5 (mm) O / 12.7 O / 6.4 (mm) 25 (Polyvinyl choride tube) Drain port (Nominal dia. mm) Sound pressure level (Note 2) (dB(A)) (High/Mid/Low) 762/642/522 60 (W) Air filter Connecting Liquid side pipe 660/552/468 36/32/28 37/33/28 37/33/29 40/35/30 44/39/34 Available PMV Kit Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-2 -1 60Hz Specifications (60Hz) Model name Cooling/Heating capacity (Note 1) MMU- AP0071MH AP0091MH AP0121MH AP0151MH AP0181MH (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 Power supply Electrical characteristics 1 phase 60Hz 220V (Separate power supply for indoor units is required.) (A) 0.27 0.29 0.30 0.33 0.41 Power consumption (kW) 0.034 0.036 0.038 0.041 0.052 Starting current (A) 0.49 0.52 0.54 0.59 0.73 Running current Main unit Appearance Ceiling panel Zinc hot dipping steel plate *Heat-insulating material attached to only upper plate Model RBC-UM11PG(W)E Panel color Moon white (Munsell/2.5GY 9.0/0.5) Height (mm) 268 Width (mm) 575 Depth (mm) 575 Height (mm) 27 Width (mm) 700 Depth (mm) 700 Main unit (kg) 17 Ceiling panel (kg) 3 Main unit Outer dimension Ceiling panel Total weigh Finned tube Heat exchanger Soundproof/Heat-insulating material Non-flammble insulation Turbo fan Fan Fan unit Standard air flow (High/Mid/Low) Motor (m3/h) 552/462/378 570/468/378 594/504/402 Long life filter Controller RBC-AMT31E Gas side (mm) Liquid side (mm) O / 9.5 O / 12.7 O / 6.4 23 (Polyvinyl choride tube) Drain port (Nominal dia. mm) Sound pressure level (Note 2) (dB(A)) (High/Mid/Low) 762/642/522 60 (W) Air filter Connecting pipe 660/552/468 36/32/28 37/33/28 37/33/29 PMV Kit 40/35/30 44/39/34 Available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 9-2 -2 O O O 9-2-2. Dimension MMU-AP0071MH, AP0091MH, AP0121MH, AP0151MH, AP0181MH 4-way air Discharge Cassete Type Arialb1i0c0p34;TOSHIBA CARRIER CORPORATION 177 525 hanging bolt pitch 595 to 660 ceiling open dimension 700 Panel external dimension 214 105 42 148 145.5 134 63 21 158 Bottom face of ceiling 120 Ceiling panel 142 268 O / 162 55 93 193.5 Wiring connection port For branch duct knockout square hole O / 150 64 Drain discharge port 256 105 70.5 97.5 Hanging bolt M10 or W3/8 local arrange 220.5 Refrigerant pipe (Gas) 0151, 0181MH................. O / 12.7 0071, 0091, 0121MH....... O / 9.5 27 MMU-AP0151MH MMU-AP0181MH 149 64 29 368.5 525 hanging bolt pitch 331.5 Model name MMU-AP0071MH MMU-AP0091MH 595 to 660 ceiling open dimension 575 unit external dimension 142 Knockout for flesh air intake O / 100 MMU-AP0121MH 190.5 175 235 320.5 575 unit external dimension 105 235 Electric parts box 700 Panel external dimension Bottom face of ceiling O / 162 Refrigerant pipe (Liquid) O / 6.4 207 70.5 For bracch duct knockout square hole O / 150 145.5 105 93 Bottom face of ceiling 1000 or more 15 or more 15 or more Bottom face Drain-up standing-up size of ceiling 1000 or more 595 to 660 ceiling open dimension Indoor unit 200 Stand-up 827.5 or less Stand-up 850 or less 300 (NOTE) As ABS is used for the drain discharge port of the main unit, the vinyl chloride paste cannot be used. Use the flexible hose (Band fix) included in the package. Check port ( 450) 1000 or more 595 to 660 ceiling open dimension Obustacle Space required for installation and servicing Wired remote controller RBC-AMT31E Wireless remote controller kit TCB-AX21E2 Simple wired remote controller RBC-AS21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 9-2 -3 Note: All dimensions are in mm. 9-2-3. Wiring diagram Model:MMU-AP007MH, AP0091MH, AP0121MH, AP0151MH, AP0181MH 9-2 -4 9-2-4. Sensible capacity table (MMU-AP***MH) Cooling capacity Unit size 007 009 012 Outdoor air temp. CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 14.0CWB 20CDB TC SHC 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.7 1.5 1.7 1.4 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.2 1.7 2.2 1.7 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 2.9 2.1 2.8 2.1 16.0CWB 23CDB TC SHC 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 1.9 1.6 1.9 1.5 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.8 2.4 1.8 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.2 2.3 3.1 2.2 TC:Total capacity[kW] SHC:Sensible capacity[kW] Indoor air temp. 18.0CWB 19.0CWB 20.0CWB 22.0CWB 24.0CWB 26CDB 27CDB 28CDB 30CDB 32CDB TC SHC TC SHC TC SHC TC SHC TC SHC 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.1 1.7 2.1 1.6 2.2 1.6 2.3 1.6 2.4 1.6 2.0 1.6 2.1 1.6 2.1 1.6 2.3 1.6 2.4 1.5 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.6 1.9 2.7 1.9 2.8 1.9 3.0 1.9 3.1 1.9 2.6 1.9 2.6 1.9 2.7 1.9 2.9 1.9 3.0 1.8 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.4 2.4 3.5 2.4 3.6 2.4 3.8 2.4 4.0 2.3 3.3 2.4 3.4 2.4 3.5 2.4 3.7 2.3 3.9 2.3 9-2 -5 Cooling capacity (cont.) Unit size 015 018 Outdoor air temp. CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 14.0CWB 20CDB TC SHC 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.6 2.7 3.5 2.6 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.5 3.1 4.3 3.0 16.0CWB 23CDB TC SHC 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.0 2.8 3.8 2.8 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 4.9 3.3 4.8 3.2 18.0CWB 26CDB TC SHC 4.4 3.1 4.4 3.1 4.4 3.1 4.4 3.1 4.4 3.1 4.4 3.1 4.4 3.1 4.4 3.1 4.4 3.1 4.4 3.1 4.4 3.1 4.4 3.1 4.4 3.1 4.4 3.1 4.2 3.0 4.1 2.9 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.3 3.5 5.1 3.4 Indoor air temp. 19.0CWB 27CDB TC SHC 4.5 3.1 4.5 3.1 4.5 3.1 4.5 3.1 4.5 3.1 4.5 3.1 4.5 3.1 4.5 3.1 4.5 3.1 4.5 3.1 4.5 3.1 4.5 3.1 4.5 3.1 4.5 3.1 4.4 3.0 4.2 2.9 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.4 3.5 5.3 3.4 9-2 -6 20.0CWB 28CDB TC SHC 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.5 3.0 4.4 2.9 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.6 3.5 5.4 3.4 22.0CWB 30CDB TC SHC 4.9 3.1 4.9 3.1 4.9 3.1 4.9 3.1 4.9 3.1 4.9 3.1 4.9 3.1 4.9 3.1 4.9 3.1 4.9 3.1 4.9 3.1 4.9 3.1 4.9 3.1 4.9 3.1 4.7 3.0 4.6 2.9 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 5.9 3.5 5.7 3.4 24.0CWB 32CDB TC SHC 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.0 2.9 4.8 2.8 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.2 3.4 6.0 3.3 Heating capacity Unit size 007 009 012 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.6 2.6 2.6 2.6 2.0 2.1 2.3 2.3 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.3 3.3 3.3 3.3 2.5 2.7 2.8 2.9 3.1 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.2 4.2 4.2 4.2 SHC : Sensible Heat Capacity (kW) Indoor air temp. °CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 1.5 1.5 1.5 1.4 1.6 1.6 1.6 1.5 1.7 1.7 1.7 1.6 1.8 1.8 1.7 1.7 1.9 1.9 1.8 1.8 2.0 2.0 1.9 1.9 2.1 2.0 2.0 1.9 2.2 2.1 2.1 2.0 2.3 2.2 2.2 2.1 2.4 2.3 2.3 2.2 2.5 2.4 2.4 2.3 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.0 1.9 1.9 1.8 2.1 2.1 2.0 1.9 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.1 2.4 2.4 2.3 2.3 2.6 2.5 2.4 2.4 2.7 2.6 2.6 2.5 2.8 2.7 2.7 2.6 2.9 2.9 2.8 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 2.9 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 2.5 2.4 2.3 2.3 2.6 2.6 2.5 2.4 2.8 2.7 2.7 2.6 2.9 2.8 2.7 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 3.0 3.3 3.3 3.2 3.1 3.5 3.4 3.3 3.3 3.7 3.6 3.5 3.4 3.8 3.7 3.6 3.5 3.9 3.9 3.8 3.7 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 9-2 -7 Heating capacity (cont.) Unit size 015 018 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.1 3.3 3.6 3.7 3.9 4.1 4.3 4.5 4.7 4.8 5.0 5.2 5.2 5.2 5.2 5.2 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 Indoor air temp. °CDB 18.0 20.0 22.0 SHC SHC SHC 3.1 3.0 2.9 3.3 3.2 3.1 3.5 3.4 3.3 3.6 3.5 3.4 3.8 3.7 3.6 4.0 3.9 3.8 4.2 4.1 4.0 4.4 4.3 4.2 4.6 4.5 4.4 4.7 4.6 4.5 4.9 4.8 4.7 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 3.9 3.8 3.7 4.1 4.0 3.9 4.4 4.3 4.2 4.5 4.4 4.3 4.8 4.7 4.6 5.0 4.9 4.8 5.3 5.2 5.0 5.5 5.4 5.3 5.8 5.6 5.5 6.0 5.9 5.7 6.2 6.1 5.9 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 24.0 SHC 2.9 3.0 3.2 3.3 3.5 3.7 3.9 4.1 4.2 4.4 4.6 4.8 4.8 4.8 4.8 4.8 3.6 3.8 4.1 4.2 4.4 4.7 4.9 5.1 5.3 5.6 5.8 6.0 6.0 6.0 6.0 6.0 9-2 -8 9-2-5. Air throw distance chart Air Speed Distribution MMU-AP0071MH MMU-AP0091MH 2.7m 2.7m 0.7m/s 0.7m/s 2 2 0.5m/s 0.5m/s 1 1 0.3m/s 0.3m/s 0 1 2 4 3 0 5m MMU-AP0121MH 1 2 3 4 5m 4 5m MMU-AP0151MH 2.7m 2.9m 0.7m/s 3 0.7m/s 2 2 0.5m/s 1 1 0.3m/s 0 1 2 4 3 0.5m/s 0.3m/s 5m 0 MMU-AP0181MH 3.2m 1 2 3 MMU-AP0151MH,MMU-AP0181MH (High ceiling mode) 3.2m 3 2 1 0 1 2 3 0.7m/s 3 0.5m/s 2 0.3m/s 1 4 5m 0.7m/s 0.5m/s 0.3m/s 0 9-2 -9 1 2 3 4 5m 9-2-6. Sound characteristics (NC-Curve) MMU-AP0071MH Octave band sound pressure level (dB) [Measuring location] 1.5m Microphone Fan Tap H M L Sound pressure level (dB(A)) 36 32 28 70 60 50 NC-50 40 NC-40 H 30 NC-30 M L 20 NC-20 Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 8000 Octave band frequency (Hz) MMU-AP0121MH H M L Fan Tap H M L Sound pressure level (dB(A)) 37 33 28 Sound pressure level (dB(A)) 37 33 29 70 Octave band sound pressure level (dB) Octave band sound pressure level (dB) MMU-AP0091MH Fan Tap 60 50 NC-50 40 NC-40 H M L 30 NC-30 20 NC-20 Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 70 60 50 NC-50 40 NC-40 H M L 30 20 NC-20 Approximate threshold of hearing for continuous noise 10 63 8000 125 Octave band frequency (Hz) 1000 2000 M L Fan Tap H M L Sound pressure level (dB(A)) 40 35 30 Sound pressure level (dB(A)) 44 39 34 60 50 NC-50 40 H M L 30 NC-40 NC-30 20 NC-20 Approximate threshold of hearing for continuous noise 250 500 1000 4000 8000 MMU-AP0181MH H Octave band sound pressure level (dB) Octave band sound pressure level (dB) 500 Fan Tap 70 125 250 Octave band frequency (Hz) MMU-AP0151MH 10 63 NC-30 2000 4000 8000 Octave band frequency (Hz) 70 60 50 NC-50 H M 40 NC-40 L NC-30 30 20 NC-20 Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 Octave band frequency (Hz) 9-2 -10 4000 8000 9-2-7. Accessories Apperarance Standard accessories Part name Qty Use Shape Installation Manual 1 (Be sure to hand over to customer) Heat insulating pipe 2 For heat insulating of pipe connecting section Installation pattern 1 For confirmation of ceiling opening and main unit position Installation gauge 2 For positioning of ceiling position (united with installation pattern) Pattern fixing screw 4 Heat insulator 1 For heat insulating of drain connecting section Washer 8 For hanging down unit Hose band 1 For connecting drain pipe Flexible hose 1 For centering the drain pipe Heat insulator 1 For sealing the wire connection opening M5 x 16 For attaching pattern Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-2 -11 Optional accessories Auxiliary fresh air Flange Air discharge direction kit TCB-FF101URE2 Fresh air inlet Box ********* Fresh air Chamber ********* Spacer for height adjustment ********* Ceiling panel RBC-UM11PG(W)E Name Model name Note Ceiling panel RBC-UM11PG(W)E Auxiliary Fresh Air Flange TCB-FF101URE2 Frech Air and Filter Chamber TBD Fresh air inlet Box TBD Spacer for height adjustment TBD Air discharge direction kit TBD Required accessory For easy fresh air intake by using the knockout hole of indoor unit.(dia=100mm) This product is scheduled to go on sale 9-2 -12 9-3-1. Specifications 50Hz Specifications (50Hz) Model name MMU- AP0071WH Cooling/Heating capacity (Note 1) Power supply Electrical characteristics Running current 2.2/2.5 AP0121WH AP0151WH AP0181WH AP0241WH AP0271WH AP0301WH 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 9.0/10.0 (kW) 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) (A) 0.31 0.32 0.46 0.47 Power consumption (kW) 0.070 0.072 0.105 0.106 99 98 0.89 0.98 Power factor (%) Starting current (A) Main unit Appearance AP0091WH Ceiling panel Main unit Outer dimension Ceiling panel 97 0.47 0.60 Heat-insulating material attached Zinc hot dipping steel plate RBC-UW136PG Model RBC-UW266PG Panel color Light ivory (Munsell 10Y 9/0.5) Height (mm) 398 Width (mm) 830 1,350 Depth (mm) 550 Height (mm) 8 Width (mm) 1,000 1,520 Depth (mm) 650 Main unit (kg) 33 Ceiling panel (kg) 8 44 48 Total weigh 11 Finned tube Heat exchanger Soundproof/Heat-insulating material Non-flammable insulation Centrifugal fan Fan Fan unit Standard air flow (High/Mid/Low) Motor (m3/h) (W) 570/510/450 780/700/600 53 39 Air filter 53 Remote controller Gas side (mm) Liquid side (mm) O / 9.5 Sound pressure level (Note 2) (dB(A)) (High/Mid/Low) O / 12.7 O / 6.4 O / 15.9 O / 9.5 25 (Polyvinyl chloride tube) Drain port (Nominal dia. mm) PMV Kit 1260/ 1140/ 960 Standard filter (Long life filter) Controller Connecting pipe 1140/960/720 34/32/30 35/33/30 38/35/33 40/37/34 Not available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-3 -1 60Hz Specifications (60Hz) Model name MMU- Cooling/Heating capacity (Note 1) (kW) AP0091WH AP0121WH AP0151WH AP0181WH AP0241WH AP0271WH AP0301WH 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 9.0/10.0 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Power supply Running current Electrical characteristics AP0071WH (A) 0.33 0.38 0.53 0.58 Power consumption (kW) 0.070 0.076 0.115 0.123 Power factor (%) 97 90 99 96 Starting current (A) 0.46 0.59 0.87 0.96 Heat-insulating material attached Zinc hot dipping steel plate Main unit Appearance Ceiling panel Main unit Outer dimension Ceiling panel Model RBC-UW136PG RBC-UW266PG Panel color Light ivory (Munsell 10Y 9/0.5) Height (mm) Width (mm) Depth (mm) 550 Height (mm) 8 Width (mm) Depth (mm) 398 1.350 830 1,520 1,000 650 Main unit (kg) 33 Ceiling panel (kg) 8 44 48 Total weight 11 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Centrifugal fan Fan Fan unit Standard air flow (High/Mid./Low) Motor (m3/h) (W) 570/510/450 780/700/600 1,140/960/720 53 39 53 Air filter 1,260/1,140/960 Standard filter (Long life filter) Controller Remote controller (mm) Gas side Connecting Liquid side pipe Drain port O / 12.7 O / 9.5 (mm) O / 9.5 O / 6.4 (Nominal dia.mm) Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) O / 15.9 25 (Polyvinyl chloride tube) 35/33/30 34/32/30 PMV Kit 38/35/33 40/37/34 Not available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 9-3 -2 O O O 9-3-2. Dimension MMU-AP0071WH, AP0091WH, AP0121WH Z view Center of panel Center of main unit Air discharge port (2-way) 1000 Electric parts box 95 650 Hanging bolt pitch 480 Unit external dimension 550 Ceiling open dimension 620 Panel external dimension 650 35 Air suction port (2-way) 30 Unit external dimension 830 Hanging bolt pitch 880 Ceiling open dimension 960 Panel external dimension 1000 Hanging bolt 4-M10 procured locally 265 Ceiling panel (Procured locally) Z Bottom face of ceiling Branch duct knockout hole (also on opposite side) 508mm or less 100mm or less 160mm or less Space required for installation and servicing 222 1000 or more 1000 or more Indoor unit Bottom face of ceiling Refrigerant pipe connecting port (Gas side O / 9.5) 100 Refrigerant pipe connecting port (Liquid side O / 6.4) 75 55 Pour water port ¯ 150 Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Drain pipe connecting port Inner O / 32, Nominal O/ 25 for vinyl chloride pipe 56 78 35 210 Power supply connecting port 35 178 242 282 348 Obstruction 60 156 1000 or more 0 ¯ 20 8 398 Ceiling 53 5mm or more Knockout hole for taking-in air (Only at reverse side) Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Note: All dimensions are in mm. 9-3 -3 MMU-AP0151WH, AP0181WH, AP0241WH, AP0271WH. AP0301WH Z view Center of main unit Center of panel Air discharge port (2-way) Electric parts box Air suction port (2-way) 650 Hanging bolt pitch 480 Unit external dimension 550 Ceiling open dimension 620 Panel external dimension 650 95 35 30 Unit external dimension 1350 Hanging bolt pitch 1400 Ceiling open dimension 1480 Panel external dimension 1520 Space required for installation and servicing 53 156 398 1000 or more 1000 or more 60 8 Obstruction 0 ¯ 20 222 5mm or more 1000 or more Ceiling Hanging bolt 4-M10 procured locally 295 Ceiling panel (Procured locally) Bottom face of ceiling Z 508mm or less Drain pipe connecting port Inner O / 32, Nominal O/ 25 for vinyl chloride pipe 75 55 Pour water port Refrigerant pipe connecting port (Gas side O / B) 56 Refrigerant pipe connecting port 100 (Liquid side O A) Bottom face of ceiling / 35 35 78 Wired remote controller RBC-AMT31E ¯ 150 210 Power supply connecting port Simple wired remote controller RBC-AS21E2 Knockout hole for air intake (Only at reverse side) Model MMU-AP0151WH to AP0181WH MMU-AP0241WH to AP0301WH Wireless remote controller kit TCB-AX21E2 178 242 282 348 100mm or less 160mm or less Branch duct knockout hole (Also on opposite side) A B O / 6.4 O / 12.7 O / 9.5 O / 15.9 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Note: All dimensions are in mm. 9-3 -4 MMU-AP0481WH*CHINA market only Z view Center of panel Center of main unit Air suction port (2-way) 680 Ceiling open dimension 650 Panel external dimension 680 Hanging bolt pitch 510 Unit external dimension 620 5 95 Air discharge port (2-way) 1898 Electric parts box 105 Unit external dimension 1650 Hanging bolt pitch 1700 Ceiling open dimension 1850 Panel external dimension 1898 1000 or more Space required for installation and servicing 68 ¯2 00 ¯2 00 406 1000 Obstruction or more 60 8 Ceiling 230 166 5mm or more 1000 or more Hanging bolt 4-M10 procured locally 150 455 Ceiling panel (Procured locally) Z Bottom face of ceiling Refrigerant pipe connecting port (Gas side O / 15.9) Refrigerant pipe 56 connecting port 100 (Liquid side O 9.5) / 15 86 Bottom face of ceiling Drain pipe connecting port (VP25) 75 55 Pour water port 50 ¯1 15 186 250 290 356 516mm or less 100mm or less 160mm or less Branch duct knockout hole (Also on reverse side) 210 Power supply Knockout hole for air intake connecting port (Only at reverse side) 2.7 • Wired remote controller (RBC-AMT21E) 4 Wired remote controller RBC-AMT31E 120 Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 120 16 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Note: All dimensions are in mm. 9-3 -5 Power supply Single phase 220-240V 50Hz 220V 60Hz Closed end connector Flow selector unit earth screw Indoor unit Earth screw R(L) S(N) RED : RED WHI : WHITE YEL :YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication 1 (BLK) CN044 1 (BRW) 2 Outdoor unit U1 U2 1 2 1 2 CN1 (WHI) Remote controller U1 U2 BLK RC YEL BLU ORN L 1 2 3 4 5 RY005 RY006 M CN050 (WHI) H CN02 (BLU) 3 3 2 1 1 MCC-1401 LM FS TR 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) Sub P.C. board MCC-1520 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) CN075 (WHI) 1 2 3 4 5 6 CN061 (YEL) 3. indicates the control P.C. board. PMV PMV CN060 (WHI) Symbol FM RC LM TR TA TC1,TC2,TCJ RY001 RY002 RY004 RY005~007 FS DM PMV 1 2 3 4 5 1 1 2 2 TA Filter TC1 TC2 TCJ 1 EXCT 2 Parts name Fan motor Running capacitor Transformer Louver motor Indoor temp sensor Temp sensor Louver control relay Drain control relay Heater control relay Fan motor control relay Float switch Drain pump motor Pulse Motor Valve Option 1 2 3 4 5 6 Fan drive 1 2 CN032 (WHI) CN081 (BLK) CN070 (WHI) CN073 (RED) CN080 (GRN) 1 2 PNL 3 1 1 2 2 3 3 1 1 2 2 CN101 (BLK) CN100 (BRW) 1 1 2 2 1 1 2 2 CN102 (RED) CN104 (YEL) 1 2 3 4 5 6 (BLU) 1 2 3 4 5 6 CN082 6 4 3 1 2 5 6 4 3 1 2 5 Indoor control P.C. board 1 2 3 4 5 6 1 2 3 4 5 6 Power supply circuit RY001 indicates the terminal block, the letter inside indicates the terminal number. 1 2 3 1 2 3 CN074 (WHI) RY002 UL DP FS 1 2 3 (BLU) 1 2 3 (GRN) 1 2 3 (RED) 1 2 3 CN068 1 2 3 CN033 1 2 3 CN030 DM 1 2 1 2 LM 2 . A dotted line and broken line indicate the wiring on site. 1. CN03 (RED) 1 1 2 2 Network CN01 1 2 adaptor (WHI) 1 2 (Option) RY007 RED FAN 9 8 7 6 5 4 3 2 1 CN083(WHI) 9 8 7 6 5 4 3 2 1 A B X Y 1 2 3 1 2 3 CN040 CN041 (BLU) (BLU) 1 2 1 2 Line Filter TR Fuse T5.0A RY004 P301 1 1 2 2 CN067 250V~ (BLK) 3 3 1 1 2 2 3 3 CN066 1 (WHI) 2 CN039 (YEL) 3 CN304 (GRY) 2 9 BLK FM WHI 1 2 RED 3 4 5 6 7 BLU BLU 9-3 -6 BLK 1 2 3 4 5 6 7 9-3-3. Wiring diagram Model:MMU-AP0071WH, AP0091WH, AP0121WH, AP0151WH, AP0181WH, MMU-AP0241WH, AP0271WH, AP0301WH, AP0481WH 9-3-4. Sensible capacity table (MMU-AP***WH) Cooling capacity Unit size 007 009 012 015 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 1.9 1.6 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 1.9 2.4 1.9 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.2 2.3 3.1 2.2 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.0 3.0 3.9 2.8 18.0°CWB 26°CDB TC SHC 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.0 1.7 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.6 2.0 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.4 2.5 3.4 2.4 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.3 3.1 4.2 3.0 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0°CWB 20.0°CWB 22.0°CWB 24.0°CWB 27°CDB 28°CDB 30°CDB 32°CDB TC SHC TC SHC TC SHC TC SHC 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.2 1.8 2.4 1.7 2.5 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.6 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.7 2.1 2.8 2.1 3.0 2.0 3.1 2.0 2.7 2.0 2.8 2.0 2.9 2.0 3.1 1.9 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.4 3.8 2.4 4.0 2.4 3.5 2.4 3.6 2.4 3.8 2.3 3.9 2.3 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.4 3.1 4.5 3.1 4.8 3.1 5.0 3.0 4.3 3.0 4.4 3.0 4.7 3.0 4.9 2.9 9-3 -7 Cooling capacity (cont.) Unit size 018 024 027 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.0 3.6 4.9 3.5 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.3 4.6 6.2 4.4 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.3 4.6 6.2 4.4 18.0°CWB 26°CDB TC SHC 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.3 3.8 5.2 3.7 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.7 4.9 6.6 4.7 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.7 4.9 6.6 4.7 Indoor air temp. 19.0°CWB 27°CDB TC SHC 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.5 3.8 5.4 3.7 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.0 4.9 6.8 4.7 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.0 4.9 6.8 4.7 9-3 -8 20.0°CWB 28°CDB TC SHC 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.7 3.8 5.5 3.7 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.2 4.9 7.0 4.7 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.2 4.9 7.0 4.7 22.0°CWB 30°CDB TC SHC 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.0 3.8 5.9 3.6 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.6 4.9 7.4 4.7 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.6 4.9 7.4 4.7 24.0°CWB 32°CDB TC SHC 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.3 3.7 6.1 3.6 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 7.9 4.7 7.8 4.6 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 7.9 4.7 7.8 4.6 Heating capacity Unit size 007 009 012 015 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.6 2.6 2.6 2.6 2.0 2.1 2.3 2.3 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.3 3.3 3.3 3.3 2.5 2.7 2.8 2.9 3.1 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.2 4.2 4.2 4.2 3.1 3.3 3.6 3.7 3.9 4.1 4.3 4.5 4.7 4.8 5.0 5.2 5.2 5.2 5.2 5.2 SHC : Sensible Heat Capacity (kW) Indoor air temp. °CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 1.5 1.5 1.5 1.4 1.6 1.6 1.6 1.5 1.7 1.7 1.7 1.6 1.8 1.8 1.7 1.7 1.9 1.9 1.8 1.8 2.0 2.0 1.9 1.9 2.1 2.0 2.0 1.9 2.2 2.1 2.1 2.0 2.3 2.2 2.2 2.1 2.4 2.3 2.3 2.2 2.5 2.4 2.4 2.3 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.0 1.9 1.9 1.8 2.1 2.1 2.0 1.9 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.1 2.4 2.4 2.3 2.3 2.6 2.5 2.4 2.4 2.7 2.6 2.6 2.5 2.8 2.7 2.7 2.6 2.9 2.9 2.8 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 2.9 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 2.5 2.4 2.3 2.3 2.6 2.6 2.5 2.4 2.8 2.7 2.7 2.6 2.9 2.8 2.7 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 3.0 3.3 3.3 3.2 3.1 3.5 3.4 3.3 3.3 3.7 3.6 3.5 3.4 3.8 3.7 3.6 3.5 3.9 3.9 3.8 3.7 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 3.1 3.0 2.9 2.9 3.3 3.2 3.1 3.0 3.5 3.4 3.3 3.2 3.6 3.5 3.4 3.3 3.8 3.7 3.6 3.5 4.0 3.9 3.8 3.7 4.2 4.1 4.0 3.9 4.4 4.3 4.2 4.1 4.6 4.5 4.4 4.2 4.7 4.6 4.5 4.4 4.9 4.8 4.7 4.6 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 9-3 -9 Heating capacity (cont.) Unit size 018 024 027 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 5.0 5.3 5.7 5.8 6.2 6.5 6.8 7.1 7.4 7.7 8.0 8.3 8.3 8.3 8.3 8.3 5.6 6.0 6.4 6.6 7.0 7.3 7.7 8.0 8.4 8.7 9.0 9.4 9.4 9.4 9.4 9.4 Indoor air temp. °CDB 18.0 20.0 22.0 SHC SHC SHC 3.9 3.8 3.7 4.1 4.0 3.9 4.4 4.3 4.2 4.5 4.4 4.3 4.8 4.7 4.6 5.0 4.9 4.8 5.3 5.2 5.0 5.5 5.4 5.3 5.8 5.6 5.5 6.0 5.9 5.7 6.2 6.1 5.9 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 4.9 4.8 4.7 5.2 5.1 5.0 5.6 5.5 5.3 5.7 5.6 5.5 6.1 5.9 5.8 6.4 6.2 6.1 6.7 6.6 6.4 7.0 6.9 6.7 7.3 7.1 7.0 7.6 7.4 7.3 7.9 7.7 7.5 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 5.5 5.4 5.3 5.9 5.8 5.6 6.3 6.1 6.0 6.5 6.3 6.2 6.8 6.7 6.5 7.2 7.0 6.9 7.5 7.4 7.2 7.9 7.7 7.5 8.2 8.0 7.8 8.5 8.4 8.2 8.9 8.7 8.5 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 24.0 SHC 3.6 3.8 4.1 4.2 4.4 4.7 4.9 5.1 5.3 5.6 5.8 6.0 6.0 6.0 6.0 6.0 4.6 4.9 5.2 5.3 5.6 5.9 6.2 6.5 6.8 7.1 7.3 7.6 7.6 7.6 7.6 7.6 5.1 5.5 5.8 6.0 6.3 6.7 7.0 7.3 7.6 7.9 8.3 8.6 8.6 8.6 8.6 8.6 9-3 -10 9-3-5. Air throw distance chart MMUAP0071WH, AP0091WH, AP0121WH MMUAP0151WH, AP0181WH 2.7m Ceiling height (m) Ceiling height (m) 2.7m 2 1.0 0.5 (m) 1 0.3 0.3 0 1 2 2 1.0 (m) 1 0.5 0.3 0.3 0 3m Horizontal distance (m) 1 2 3m Horizontal distance (m) MMU-AP0241WH, AP0271WH Ceiling height (m) 2.7m 2 1.0 (m) 1 0.5 0.3 0.3 0 1 2 3m Horizontal distance (m) MMU-AP0481WH MMU-AP0301WH 2.7 Ceiling height (m) Ceiling height (m) 2.7 2 1.0 1 0.5 0.3 0 2 1.0 1 0.3 1 2 3 0.5 0.3 0.3 4 0 1 2 3 Horizontal distance (m) Horizontal distance (m) 9-3 -11 4 9-3-6. Sound characteristics (NC-Curve) Sound level values shown are based on a measurement in a non resound room. MMU-AP0071WH, AP0091WH, AP0121WH Fan Tap H M L Sound pressure level (dB(A)) 34 32 30 Microphone Octave band sound pressure level (dB) standard sound pressure 0.0002 µbar Audibility limits of continuous white level Octave band frequency (Hz) MMU-AP0241WH, AP0271WH MMU-AP0151WH, AP0181WH Fan Tap Sound pressure level (dB(A)) H 35 M 33 L 30 Audibility limits of continuous white level H M L 38 35 33 standard sound pressure 0.0002 µbar Octave band sound pressure level (dB) Octave band sound pressure level (dB) standard sound pressure 0.0002 µbar Fan Tap Sound pressure level (dB(A)) Octave band frequency (Hz) Audibility limits of continuous white level Octave band frequency (Hz) 9-3 -12 Octave band sound pressure level (dB) MMU-AP0301WH Fan T ap Tap H M L Sound pressure level (dB(A)) 40 37 34 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 H M 20 Audibility limits of continuous white level NC-20 L 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) 9-3 -13 (Revised edition in 7.Apr.2006) 9-3-7. Accessories Apperarance Standard accessories Qty Shape Installation Manual 1 — Heat insulating pipe 2 Installation pattern Part name MMU-AP0301WH type or lower 1 MMU-AP0481WH type 2 — Use Part name Qty (Be sure to hand over to customer) Installation gauge 1 For heat insulating pipe connecting section Pattern fixing screw 6 Fan motor For checking the connector position of the ceiling openings and the Heat unit insulator Shape Use For positioning of ceiling position (United with installation pattern) For attaching the installation pattern M 5 x 16 1 For changing fan motor r.p.m. to apply higher ceiling 1 For seal for wire connecting port Ceiling panel components Name Ceiling panel Center panel Air filter Shape (Qty) (1 set) Usage — (1 pc) — • RBC-UW466PG : Attached to indoor unit Attached to ceiling panel, and removes dust. Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-3 -14 Screw installing panel Screw installing panel 20mm 30mm M5×20 M5×30 (4 pcs) For fixing ceiling panel (4 corners) (2 pcs) For tentative hanging and fixing ceiling panel (Center part) Optional accessories Ceiling panel RBC-UW136PG RBC-UW266PG RBC-UW466PG Name Ceiling panel Model name RBC-UW136PG RBC-UW266PG Note Required accessory 9-3 -15 9-4-1. Specifications 50Hz Specifications (50Hz) Model name MMU- AP0071YH AP0091YH AP0121YH AP0152SH AP0182SH AP0242SH (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 Cooling/Heating capacity (Note 1) Power supply Electrical characteristics (Note 2) 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) Running current (A) 0.24 0.34 0.37 0.62 Power consumption (kW) 0.053 0.042 0.046 0.075 Power factor (%) 95 _ _ _ Starting current (A) 0.6 0.53 0.54 0.80 Main unit Appearance Ceiling panel Heat-insulating material attached Zinc hot dipping steel plate Model Panel color RBC-UY135PG RBC-US21PGE W : Silky shade (1Y8.5/0.5) Moon white (Munsel 2.5GY9.0/0.5) Height (mm) 235 200 Width (mm) 850 1,000 Depth (mm) 400 710 Height (mm) 18 20 Width (mm) 1,050 1,230 Depth (mm) 470 800 Main unit (kg) 22 Ceiling panel (kg) 3.5 Main unit Outer dimension Ceiling panel 21 22 Total weigh 5.5 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Centrifugal fan Fan Fan unit Standard air flow (High/Mid/Low) Motor (m3/h) (W) 540/480/420 750/690/630 780/720/660 1,140/960/810 22 30 Remote controller Controller Standard filter (Long life filter) Air filter Connecting pipe Polyethylene foam + Expanded polystyrene Gas side (mm) Liquid side (mm) Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) O / 9.5 O / 12.7 O / 15.9 O / 6.4 O / 9.5 25 (Polyvinyl chloride tube:External dia.32 Internal dia.25) 42/39/34 PMV Kit 37/35/32 38/36/34 45/41/37 Available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-4 -1 60Hz Specifications (60Hz) Model name MMU- AP0071YH AP0091YH AP0121YH AP0152SH AP0182SH AP0242SH (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 Cooling/Heating capacity (Note 1) Power supply Electrical characteristics (Note 2) 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Running current (A) 0.26 0.35 0.39 0.62 Power consumption (kW) 0.056 0.041 0.045 0.073 Power factor (%) 98 _ _ _ Starting current (A) 0.60 0.53 0.54 0.80 Main unit Appearance Ceiling panel Heat-insulating material attached Zinc hot dipping steel plate Model Panel color RBC-UY135PG RBC-US21PGE W : Silky shade (1Y8.5/0.5) Moon white (Munsel 2.5GY9.0/0.5) Height (mm) 235 200 Width (mm) 850 1,000 Depth (mm) 400 710 Height (mm) 18 20 Width (mm) 1,050 1,230 Depth (mm) 470 800 Main unit (kg) 22 Ceiling panel (kg) 3.5 Main unit Outer dimension Ceiling panel 21 22 Total weigh 5.5 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Centrifugal fan Fan Fan unit Standard air flow (High/Mid/Low) Motor (m3/h) (W) 540/480/420 750/690/630 780/720/660 1,140/960/810 22 30 Remote controller Controller Standard filter (Long life filter) Air filter Connecting pipe Polyethylene foam + Expanded polystyrene Gas side (mm) Liquid side (mm) Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) O / 9.5 O / 12.7 O / 15.9 O / 6.4 O / 9.5 25 (Polyvinyl chloride tube:External dia.32 Internal dia.25) 42/39/34 PMV Kit 37/35/32 38/36/34 45/41/37 Available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-4 -2 9-4-2. Dimension MMU-AP0071YH, AP0091YH, AP0121YH Panel external dimension 1050 Drain pipe connecting port (VP25) 20 Power supply connecting port Panel external dimension 470 Ceiling open dimension 430 20 Ceiling open dimension 1010 Center of panel Hanging bolt 4-M10 procured locally Support metal Refrigerant pipe connecting port (Gas side) Ø9.5 Discharge louver Refrigerant pipe connecting port (Liquid side) Ø6.4 Ceiling panel Procured locally Air discharge port Bottom face of ceiling Panel mounting hole 5 positions Air suction port 4 2.7 Dimensions Model MMU- A B C AP0071YH,AP0091YH, AP0121YH 235 245 200 B or more Wired remote controller RBC-AMT31E 120 Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application 120 16 RBC-AMT31E and RBC-EXW21E2 100 or more 100 or more 200 or more Space required for installation and servicing Note: All dimensions are in mm. 9-4 -3 MMU-AP0152SH, AP0182SH, AP0242SH 56 Cable inlet (Knockout hole) 252 248 Drain pipe connecting port (Be sure to connect the attached flexible hose.) 112 72 Fresh air inlet (Ø92 knockout hole) 20 C/L 216 800 Panel external size 760 Ceiling opening size 220 475 Hanging bolt pitch 1060 Hanging bolt pitch 20 1190 Ceiling opening size 1230 Panel external size 20 20 135 710 Unit external size 233 122 C/L 80 60 43 Cable inlet 100 Ø112 (4-tapping screw under-hole) 94 154 Refrigerant pipe connecting port Gas side B Refrigerant pipe connecting port Liquid side A 1000 Unit external size 706 20 73.4 93 200 76 Hanging bolt M10 or W3/8 (Local supply) Lower surface of ceiling Ceiling panel (Sold separately) For front air discharge unit (Sold separately) knockout hole 4 2.7 Model name Wired remote controller RBC-AMT31E 120 Simple wired remote controller RBC-AS21E2 Wireless remote controller kit 120 TCB-AX21E2 16 Weekly timer application RBC-AMT31E and RBC-EXW21E2 9-4 -4 MMU- A B AP015, AP018 type O / 6.4 O / 12.7 AP024 type O / 9.5 O / 15.9 RED : RED WHI : WHITE YEL :YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication RED WHI Power supply Single phase 220-240V 50Hz 220V 60Hz Indoor unit Earth screw R(L) S(N) RED WHI 1 1 3 CN304 (GRY) 2 1 Heater CN301 (BLK) BLU RY004 Line Filter TR BLU 1 2 1 2 Outdoor unit U1 U2 1 2 1 2 CN1 (WHI) AI-NET central control terminal A B X Y 1 2 3 1 3 Remote controller U1 U2 BLU 1 2 1 2 YEL BLU ORN BLK RED L CN03 (RED) 1 1 2 2 LM 2 1 2 1 FS FS CN075 (WHI) TR 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) Sub P.C. board MCC-1520 1 2 3 4 5 6 CN061 (YEL) 3. indicates the control P.C. board. PMV PMV CN060 (WHI) Symbol FM RC TR LM TA TC1,TCJ RY001 RY002 RY004 RY005~007 FS DM PMV Parts name Fan motor Running capacitor Power transformer Louver motor Indoor temp sensor Temp sensor Flap motor control relay Drain pump control relay Heater control relay Fan motor control relay Float switch Drain pump motor Pulse Motor Valve Option 1 2 3 4 5 1 1 Filter 2 2 CN070 (WHI) CN081 (BLK) 1 EXCT 2 1 2 PNL 3 TC1 TCJ TA CN073 (RED) CN080 (GRN) 1 2 3 4 5 6 Fan drive 1 2 CN032 (WHI) 1 2 CN101 (BLK) 1 1 2 2 3 3 1 1 2 2 CN102 (RED) CN100 (BRW) 1 1 2 2 CN104 (YEL) 1 2 3 4 5 6 (BLU) 1 2 3 4 5 6 CN082 6 4 3 1 2 5 6 4 3 1 2 5 Indoor control P.C. board 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) 1 2 3 4 5 6 1 2 3 4 5 6 Power supply circuit RY001 indicates the terminal block, the letter inside indicates the terminal number. 1 2 3 1 2 3 CN074 (WHI) RY002 UL DP 2 1 2 1 LM 1 2 3 (BLU) 1 2 3 (GRN) 1 2 3 (RED) 1 2 3 CN068 1 2 3 CN033 1 2 3 CN030 1 2 3 1 2 3 DM 2 . A dotted line and broken line indicate the wiring on site. 1. 3 2 1 CN02 3 2 1 (BLU) Network adaptor P.C. board Network CN01 1 2 adaptor (WHI) 1 2 (Option) 1 2 3 4 5 RY005 RY006 M CN050 (WHI) H MCC-1401 RY007 FAN 9 8 7 6 5 4 3 2 1 CN083(WHI) 9 8 7 6 5 4 3 2 1 CN044 CN040 CN041 (BRW) (BLU) (BLU) 1 1 2 2 CN067 Fuse (BLK) T5.0A 3 3 CN066 1 (WHI) 2 AC IN 3 3 CN309 (YEL) 2 2 Closed end connector Flow selector unit earth screw RC BLU FM BLK 1 2 3 4 5 6 BLU 9-4 -5 BLK 1 2 3 4 5 6 9-4-3. Wiring diagram 1-way Air Discharge Cassette Type (Compact type) Model: MMU-AP0071YH, AP0091YH, AP0121YH on side 1-way (2 series) Air Discharge Cassette Type (MMU-AP***SH) 9-4 -6 9-4-4. Sensible capacity table (MMU-AP***YH, MMU-AP***SH) Cooling capacity Unit size 007 009 012 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 1.9 1.6 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.0 2.4 2.0 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.2 2.5 3.1 2.4 18.0°CWB 26°CDB TC SHC 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.0 1.7 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.7 2.2 2.6 2.1 3.5 2.7 3.5 2.7 3.5 2.7 3.5 2.7 3.5 2.7 3.5 2.7 3.5 2.7 3.5 2.7 3.5 2.7 3.5 2.7 3.5 2.7 3.5 2.7 3.5 2.7 3.5 2.7 3.4 2.7 3.4 2.5 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0°CWB 20.0°CWB 22.0°CWB 24.0°CWB 27°CDB 28°CDB 30°CDB 32°CDB TC SHC TC SHC TC SHC TC SHC 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.2 1.8 2.4 1.7 2.5 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.6 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.8 2.2 2.9 2.2 3.1 2.2 3.2 2.1 2.7 2.2 2.8 2.2 3.0 2.1 3.1 2.1 2.7 2.1 2.8 2.1 2.9 2.1 3.1 2.0 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.6 2.7 3.7 2.7 3.9 2.7 4.1 2.6 3.5 2.6 3.6 2.6 3.8 2.6 4.0 2.6 3.5 2.5 3.6 2.5 3.8 2.5 3.9 2.5 9-4 -7 Cooling capacity (cont.) Unit size 015 018 024 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.0 3.0 3.9 2.8 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.0 3.6 4.9 3.5 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.3 4.6 6.2 4.4 18.0°CWB 26°CDB TC SHC 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.3 3.1 4.2 3.0 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.3 3.8 5.2 3.7 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.7 4.9 6.6 4.7 Indoor air temp. 19.0°CWB 27°CDB TC SHC 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.4 3.1 4.3 3.0 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.5 3.8 5.4 3.7 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.0 4.9 6.8 4.7 20.0°CWB 28°CDB TC SHC 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.5 3.1 4.4 3.0 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.7 3.8 5.5 3.7 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.2 4.9 7.0 4.7 9-4 -8 22.0°CWB 30°CDB TC SHC 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.8 3.1 4.7 3.0 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.0 3.8 5.9 3.6 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.6 4.9 7.4 4.7 24.0°CWB 32°CDB TC SHC 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.0 3.0 4.9 2.9 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.3 3.7 6.1 3.6 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 7.9 4.7 7.8 4.6 Heating capacity Unit size 007 009 012 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.6 2.6 2.6 2.6 2.0 2.1 2.3 2.3 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.3 3.3 3.3 3.3 2.5 2.7 2.8 2.9 3.1 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.2 4.2 4.2 4.2 SHC : Sensible Heat Capacity (kW) Indoor air temp. °CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 1.5 1.5 1.5 1.4 1.6 1.6 1.6 1.5 1.7 1.7 1.7 1.6 1.8 1.8 1.7 1.7 1.9 1.9 1.8 1.8 2.0 2.0 1.9 1.9 2.1 2.0 2.0 1.9 2.2 2.1 2.1 2.0 2.3 2.2 2.2 2.1 2.4 2.3 2.3 2.2 2.5 2.4 2.4 2.3 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.0 1.9 1.9 1.8 2.1 2.1 2.0 1.9 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.1 2.4 2.4 2.3 2.3 2.6 2.5 2.4 2.4 2.7 2.6 2.6 2.5 2.8 2.7 2.7 2.6 2.9 2.9 2.8 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 2.9 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 2.5 2.4 2.3 2.3 2.6 2.6 2.5 2.4 2.8 2.7 2.7 2.6 2.9 2.8 2.7 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 3.0 3.3 3.3 3.2 3.1 3.5 3.4 3.3 3.3 3.7 3.6 3.5 3.4 3.8 3.7 3.6 3.5 3.9 3.9 3.8 3.7 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 9-4 -9 Heating capacity (cont.) Unit size 015 018 024 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.1 3.3 3.6 3.7 3.9 4.1 4.3 4.5 4.7 4.8 5.0 5.2 5.2 5.2 5.2 5.2 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 5.0 5.3 5.7 5.8 6.2 6.5 6.8 7.1 7.4 7.7 8.0 8.3 8.3 8.3 8.3 8.3 Indoor air temp. °CDB 18.0 20.0 22.0 SHC SHC SHC 3.1 3.0 2.9 3.3 3.2 3.1 3.5 3.4 3.3 3.6 3.5 3.4 3.8 3.7 3.6 4.0 3.9 3.8 4.2 4.1 4.0 4.4 4.3 4.2 4.6 4.5 4.4 4.7 4.6 4.5 4.9 4.8 4.7 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 3.9 3.8 3.7 4.1 4.0 3.9 4.4 4.3 4.2 4.5 4.4 4.3 4.8 4.7 4.6 5.0 4.9 4.8 5.3 5.2 5.0 5.5 5.4 5.3 5.8 5.6 5.5 6.0 5.9 5.7 6.2 6.1 5.9 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 4.9 4.8 4.7 5.2 5.1 5.0 5.6 5.5 5.3 5.7 5.6 5.5 6.1 5.9 5.8 6.4 6.2 6.1 6.7 6.6 6.4 7.0 6.9 6.7 7.3 7.1 7.0 7.6 7.4 7.3 7.9 7.7 7.5 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 24.0 SHC 2.9 3.0 3.2 3.3 3.5 3.7 3.9 4.1 4.2 4.4 4.6 4.8 4.8 4.8 4.8 4.8 3.6 3.8 4.1 4.2 4.4 4.7 4.9 5.1 5.3 5.6 5.8 6.0 6.0 6.0 6.0 6.0 4.6 4.9 5.2 5.3 5.6 5.9 6.2 6.5 6.8 7.1 7.3 7.6 7.6 7.6 7.6 7.6 9-4 -10 9-4-5. Air throw distance chart 1-way Air Discharge Cassette T ype (Compact type) Type MMU-AP0071YH, AP0091YH, AP0121YH H (High wind, blowing downward) 2.7m 5.0 L (Low wind, blowing downward) 4.0 2.7m 2 2 H (High wind, blowing horizontally) 2.7m 4.5 1.7 2 2.5 L (Low wind, blowing horizontally) 2.7m 3.0 0.3 2 1.5 0.4 1.5 1.1 0.3 2.3 1 1 1 0.9 0.4 0 1 0.5 0.6 1 0.4 2 0.2 0 3m 0.3 1 0.2 2 3m 0 1 2 3m 0 1 2 3m 1-way (2 series) Air Discharge Cassette T ype Type Heating mode MMU-AP0242SH MMU-AP0152SH, AP0182SH 3.5m Main unit 3.5m Main unit 3m 3m 2m 2m 0.3 1.0 1m 0.3 1.0 0.3 1m 0.5 0.3 0.5 0.5 0.5 1m 2m 3m 4m 1m 9-4 -11 2m 3m 4m (Revised edition in 7.Apr.2006) 9-4-6. Sound characteristics (NC-Curve) 1-way Air Discharge Cassette T ype (Compact type) Type MMU-AP0071YH, AP0091YH, AP0121YH Fan tap Sound pressure level (dB(A)) H M L 42 39 34 Microphone 9-4 -12 (Revised edition in 7.Apr.2006) 1-way (2 series) Air Discharge Cassette Type MMU-AP0242SH MMU-AP0152SH Fan tap Sound pressure level (dB(A)) H M L 37 35 32 Fan tap Sound pressure level (dB(A)) M L 45 41 37 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 H 30 M NC-30 L 20 Approximate threshold of hearing for continuous noise NC-20 10 Octave band sound pressure level (dB) Octave band sound pressure level (dB) 90 H 80 70 NC-70 60 NC-60 50 NC-50 40 H M NC-40 30 L NC-30 20 Approximate threshold of hearing for continuous noise NC-20 10 63 125 250 500 1000 2000 4000 8000 63 Octave band center frequency (Hz) 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) MMU-AP0182SH Fan tap Sound pressure level (dB(A)) H M L 38 36 34 Octave band sound pressure level (dB) 90 80 70 NC-70 60 NC-60 50 NC-50 40 H M 30 L 20 Approximate threshold of hearing for continuous noise 10 63 125 250 Center 1.5m NC-40 Microphone NC-30 NC-20 500 1000 2000 4000 8000 Octave band center frequency (Hz) 9-4 -13 9-4-7. Accessories 1-way (2 series) Air Discharge Cassette Type Apperarance Standard accessories Qty Shape Installation Manual 1 — Heat insulating pipe 2 For heat insulating of pipe connecting section Installation gauge — For positioning of ceiling position Installation pattern 1 Part name Use (Be sure to hand over to customer) For confirmation of ceiling opening and main unit position — Celling panel components Part name Qty Use RBC-US135PG, 165PG, 265PG type Ceiling panel 1 — Intake grille 3 — Air filter 1 Located in the intake grille and removes dust and dirt from the air. Panel installation screw (M5 x 20) 7 For securing the ceiling panel Screw head insulation 1 set Prevents condensation from forming on screw heads 9-4 -14 Optional accessories Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-4 -15 1-way (2 series) Air Discharge Cassette Type Apperarance Standard accessories Qty Shape Installation Manual 1 This manual Installation pattern 1 For check of ceiling opening and unit position Installation gauge 1 For check of ceiling opening and unit position (Unit with installation pattern) Pattern fixing screw 4 Heat insulating pipe 2 Washer 8 Hose band 1 For connecting drain pipe Flexible hose 1 For adjustment of drain pipe centering Heat insulator 1 For insulating drain connecting section Heat insulator 1 For sealing of pipe connection port (With slit) Heat insulator 1 For sealing of pipe connection port (Without slit) Part name M5 x 16 Use (Be sure to hand over to customer) For mounting of pattern For insulating pipe connecting section M10 x ∅34 For hanging-down of unit 9-4 -16 Optional accessories Front air discharge unit TCB-BU21HWE Auxiliary fresh air Flange TCB-FF101URE Ceiling panel RBC-US21PGE Name Model name Ceiling panel RBC-US21PGE Front air discharge unit TCB-BUS21HWE Auxiliary fresh air Flange TCB-FF101URE2 Note Required accessory For easy fresh air intake by using the knockout hole of indoor unit. (dia=100mm) Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-4 -17 9-5-1. Specifications 50Hz Specifications (50Hz) Model name MMD- AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH AP0271BH AP0301BH AP0361BH AP0481BH Cooling/Heating capacity (Note 1) (kW) 2.2/2.5 Power supply Electrical characteristics Running current 3.6/4.0 4.5/5.0 5.6/6.3 0.29 0.34 0.43 0.52 0.61 0.83 0.98 Power consumption (kW) 0.033 0.039 0.050 0.060 0.071 0.107 0.128 0.5 0.59 0.75 0.90 1.05 1.44 1.70 (A) Main unit Main unit Outer dimension Suction ceiling panel Zinc hot dipping steel plate 320 Width (mm) 550 700 Depth (mm) 800 Height (mm) 9 Width (mm) 630 780 Depth (mm) 1,350 1,080 1,430 Main unit (kg) 28 32 43 55 Ceiling panel (kg) 3.5 4 6 7 Finned tube Non-flammable insulation Soundproof/Heat-insulating material Centrifugal fan Fan Standard air flow (High/Mid/Low) (m3/h) 480 (420/340) 570 650 780 (490/400) (540/480) (660/540) Motor (W) 120 External static pressure (factory setting) (Pa) 40 External static pressure (Pa) 100 Air filter 1,140 (990/870) 1,260 1,620 1,980 (1,080/870) (1,410/1,200) (1,710/1,490) Standard filter (Long life filter) Controller Connecting pipe 1,000 500 Heat exchanger Fan unit 8.0/9.0 9.0/10.0 11.2/12.5 14.0/16.0 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) Height (mm) Total weigh 7.1/8.0 (A) Starting current Appearance 2.8/3.2 Remote controller Gas side (mm) Liquid side (mm) O / 9.5 O / 12.7 O / 9.5 O / 6.4 25 (Polyvinyl chloride tube) Drain port (Nominal dia. mm) Sound pressure level (Note 2) (dB(A)) (High/Mid/Low) O / 15.9 30/28/26 31/29/27 32/30/28 PMV Kit 33/31/29 34/32/29 36/34/32 38/36/32 Not available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-5 -1 60Hz Specifications (60Hz) Model name MMD- AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH AP0271BH AP0301BH AP0361BH AP0481BH (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 9.0/10.0 11.2/12.5 14.0/16.0 Cooling/Heating capacity (Note 1) 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Power supply Electrical characteristics (A) 0.30 0.35 0.45 0.55 0.64 0.87 1.03 Power consumption (kW) 0.033 0.039 0.050 0.060 0.071 0.107 0.128 0.5 0.59 0.75 0.90 1.05 1.44 1.70 Running current (A) Starting current Appearance Main unit Zinc hot dipping steel plate 320 (mm) Height Main unit Width (mm) Depth (mm) 800 Height (mm) 9 Width (mm) Depth (mm) Outer dimension Suction ceiling panel 550 700 630 780 1,000 1,350 1,080 1,430 500 Main unit (kg) 28 32 43 55 Ceiling panel (kg) 3.5 4 6 7 Total weight Heat exchanger Finned tube Non-flammable insulation Soundproof/Heat-insulating material Centrifugal fan Fan Standard air flow (High/Mid/Low) Fan unit (m3/h) 480 (420/340) 570 (490/400) 650 (540/480) 780 (660/540) 1,140 (990/870) (W) 120 External static pressure (factory setting) (Pa) 40 External static pressure (Pa) 100 Motor Air filter 1,620 (1,410/1,200) 1,980 (1,710/1,490) 36/34/32 38/36/32 Standard filter (Long life filter) Controller Connecting pipe 1,260 (1,080/870) Remote controller Gas side (mm) Liquid side (mm) O / 9.5 O / 9.5 O / 6.4 25 (Polyvinyl chloride tube) Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) O / 15.9 O / 12.7 30/28/26 31/29/27 32/30/28 PMV Kit 33/31/29 34/32/29 Not available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 9-5 -2 O O O 9-5-2. Dimension MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH, AP0271BH, AP0301BH, AP0361BH, AP0481BH Drain pipe connecting port (Inner ø32 vinyl chloride pipe VP25 connection) Unit external dimension 40 800 Hanging bolt pitch 700 59 25 41 Hanging bolt pitch A ± 7.5 50 638 498 393 B 41 Refrigerant pipe connecting port (Gas side øF) 131 50 215 44 Air Discharge 49 70 to 270 10-ø4 tapping screw ø160 142 C (When attaching directly) ø125 knockout hole (For air intake) 91 150 Refrigerant pipe connecting port (Liquid side øG) 50 243 Hanging bolt 4-M10 (Procured locally) 196 Panel C, L ø26 power supply, remote controller wires drawing-out port Ceiling open dimension D Air Suction 240 Ceiling opening 470 E Air Suction A Model MMDAP0071BH, AP0091BH, AP0121BH 616 B D E F G 600 470 9.5 6.4 C 550 350 766 700 500 750 620 12.7 9.4 AP0241BH, AP0271BH, AP0301BH 1066 1000 800 1050 920 15.9 9.5 AP0361BH, AP0481BH 1416 1350 1150 1400 1270 15.9 9.5 AP0151BH, AP0181BH (Note) Two of high efficiency filters available Deodorant filter not available Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 (Note) Be sure to create a check port at position A as indicated in the following figure. This is for maintenance of the equipment. Air outlet Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Ceiling opening part Check port B 450mm Air filter 700mm for maintenance of air filter 271mm or less 300mm Check port A 450mm 550mm or less (150mm) 100mm or less Drain-up piping 700mm for maintenance of air filter 9-5 -3 Note: All dimensions are in mm. R(L) S(N) U1 U2 Outdoor unit 1 1 2 2 3 3 CN44 1 (BRW) 2 CN66 1 (WHI) 2 Adaputor for wired remote controller Wired remote controller CN001 (WHI) BLK 1 1 3 3 1 2 3 1 2 3 CN50 (WHI) 5 5 FM X Y (Signal output) the terminal number. 3. indicates the control P.C. board. 1 1 2 2 CN101 (BLK) 1 2 3 4 5 CN20 CN70 (BLU) (WHI) CN73 (RED) CN80 (GRN) 1 2 Symbol FM TA TC1,TC2,TCJ DM FS RY302 PMV BLK GRY PNK ORN GRN TC1 TC2 : BLACK : GRAY : PINK : ORANGE : GREEN Parts name Fan motor Indoor temp sensor Indoor temp sensor Drain pump motor Float switch Drain pump control relay Pulse Motor Valve : RED : WHITE : YELLOW : BLUE : BROWN TA TCJ 1 EXCT 2 1 2 PNL 3 1 1 2 2 3 3 1 1 2 2 CN102 (RED) CN100 (BRN) 1 1 2 2 CN104 (YEL) 3 1 CN34 3 2 1 (RED) FS Color identification RED WHI YEL BLU BRN 1 2 3 4 5 CN81 (BLK) indicates the terminal block, the letter inside indicates 1 2 3 4 5 6 1 2 CN60 (WHI) (Fan drive) CN32 (WHI) 2 . A dotted line and broken line indicate the wiring on site. 1. 1 2 CN03 1 2 (RED) Network adaptor P.C. board Network CN01 1 2 adaptor (WHI) 1 2 (Option) 3 3 2 2 1 1 CN61 (YEL) Power supply circuit DC20V DC15V DC12V DC7V CN33 1 2 3 4 5 (WHI) Indoor control P.C. board 1 2 3 4 5 6 CN82 1 2 3 4 5 6 (BLU) 6 4 3 1 2 5 6 4 3 1 2 5 PMV T10 1 2 3 4 5 6 250V~ Fuse T3.15A 1 2 3 4 5 CN02 (BLU) TR 1 2 3 1 2 3 Ð + Motor drive circuit CN333 1 (WHI) 1 CN309 (YEL) ~ ~ 1 2 1 2 WHI WHI BLK 1 2 3 1 2 3 CN41 (BLU) CN334 (WHI) 1 2 1 2 CN40 (BLU) P301 250V~ Fuse T6.3A RY302 5 4 2 1 5 4 3 2 1 1 2 1 2 CN1 (WHI) BLK A B WHI U1 U2 BLK 1 1 CN67 (BLK) 2 2 3 3 WHI RED 1 CN304 (GRY) 2 3 Flow selector unit earth screw Closed end connector WHI Reactor WHI Indoor unit power supply Single phase 220-240V 50Hz 220V 60Hz Earth screw Indoor unit RED 1 3 1 2 2 DM CN68 (BLU) BLU BLU BLK 9-5 -4 BLK 5 5 4 4 9-5-3. Wiring diagram Model: MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH MMD-AP0271BH, AP0301BH, AP0361BH, AP0481BH, AP0561BH 9-5-4. Sensible capacity table (MMD-AP***BH) Cooling capacity Unit size 007 009 012 015 Outdoor air temp. ˚CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0˚CWB 23˚CDB TC SHC 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 1.9 1.5 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 1.9 2.4 1.9 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.2 2.3 3.1 2.2 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.0 2.8 3.9 2.7 18.0˚CWB 26˚CDB TC SHC 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.0 1.6 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.6 2.0 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.4 2.5 3.4 2.4 4.4 3.0 4.4 3.0 4.4 3.0 4.4 3.0 4.4 3.0 4.4 3.0 4.4 3.0 4.4 3.0 4.4 3.0 4.4 3.0 4.4 3.0 4.4 3.0 4.4 3.0 4.4 3.0 4.3 2.9 4.2 2.8 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0˚CWB 20.0˚CWB 22.0˚CWB 24.0˚CWB 27˚CDB 28˚CDB 30˚CDB 32˚CDB TC SHC TC SHC TC SHC TC SHC 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.2 1.7 2.4 1.7 2.5 1.6 2.1 1.6 2.2 1.6 2.3 1.6 2.4 1.5 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.7 2.1 2.8 2.1 3.0 2.0 3.1 2.0 2.7 2.0 2.8 2.0 2.9 2.0 3.1 1.9 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.4 3.8 2.4 4.0 2.4 3.5 2.4 3.6 2.4 3.8 2.3 3.9 2.3 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.5 3.0 4.6 3.0 4.9 3.0 5.1 2.9 4.4 2.9 4.5 2.9 4.8 2.9 5.0 2.8 4.3 2.8 4.4 2.8 4.7 2.8 4.9 2.7 9-5 -5 Cooling capacity (cont.) Unit size 018 024 027 030 Outdoor air temp. ˚CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0˚CWB 23˚CDB TC SHC 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.0 3.4 4.9 3.3 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.3 4.6 6.2 4.4 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.1 5.2 7.0 5.0 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.0 5.7 7.8 5.5 18.0˚CWB 26˚CDB TC SHC 5.4 3.7 5.4 3.7 5.4 3.7 5.4 3.7 5.4 3.7 5.4 3.7 5.4 3.7 5.4 3.7 5.4 3.7 5.4 3.7 5.4 3.7 5.4 3.7 5.4 3.7 5.4 3.7 5.3 3.6 5.2 3.5 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.7 4.9 6.6 4.7 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.6 5.5 7.4 5.3 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.7 6.2 8.6 6.1 8.4 5.9 Indoor air temp. 19.0˚CWB 27˚CDB TC SHC 5.6 3.7 5.6 3.7 5.6 3.7 5.6 3.7 5.6 3.7 5.6 3.7 5.6 3.7 5.6 3.7 5.6 3.7 5.6 3.7 5.6 3.7 5.6 3.7 5.6 3.7 5.6 3.7 5.5 3.6 5.4 3.5 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.1 5.0 7.0 4.9 6.8 4.7 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 7.8 5.5 7.7 5.3 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 9.0 6.2 8.8 6.1 8.6 5.8 9-5 -6 20.0˚CWB 28˚CDB TC SHC 5.8 3.7 5.8 3.7 5.8 3.7 5.8 3.7 5.8 3.7 5.8 3.7 5.8 3.7 5.8 3.7 5.8 3.7 5.8 3.7 5.8 3.7 5.8 3.7 5.8 3.7 5.8 3.7 5.7 3.6 5.5 3.5 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.3 5.0 7.2 4.9 7.0 4.7 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.1 5.5 7.9 5.3 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.3 6.2 9.1 6.1 8.9 5.8 22.0˚CWB 30˚CDB TC SHC 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.0 3.6 5.9 3.4 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.6 4.9 7.4 4.7 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.5 5.4 8.4 5.2 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.6 6.0 9.4 5.8 24.0˚CWB 32˚CDB TC SHC 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.3 3.5 6.1 3.4 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 7.9 4.7 7.8 4.6 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 8.9 5.3 8.8 5.1 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.1 5.9 9.8 5.6 Cooling capacity (cont.) Unit size 036 048 Outdoor air temp. ˚CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0˚CWB 23˚CDB TC SHC 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.0 6.8 9.8 6.5 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.5 8.5 12.2 8.2 18.0˚CWB 26˚CDB TC SHC 10.9 7.3 10.9 7.3 10.9 7.3 10.9 7.3 10.9 7.3 10.9 7.3 10.9 7.3 10.9 7.3 10.9 7.3 10.9 7.3 10.9 7.3 10.9 7.3 10.9 7.3 10.9 7.3 10.6 7.2 10.4 6.9 13.6 9.2 13.6 9.2 13.6 9.2 13.6 9.2 13.6 9.2 13.6 9.2 13.6 9.2 13.6 9.2 13.6 9.2 13.6 9.2 13.6 9.2 13.6 9.2 13.6 9.2 13.6 9.2 13.3 9.0 13.0 8.7 Indoor air temp. 19.0˚CWB 27˚CDB TC SHC 11.2 7.3 11.2 7.3 11.2 7.3 11.2 7.3 11.2 7.3 11.2 7.3 11.2 7.3 11.2 7.3 11.2 7.3 11.2 7.3 11.2 7.3 11.2 7.3 11.2 7.3 11.2 7.3 11.0 7.2 10.8 6.9 14.0 9.2 14.0 9.2 14.0 9.2 14.0 9.2 14.0 9.2 14.0 9.2 14.0 9.2 14.0 9.2 14.0 9.2 14.0 9.2 14.0 9.2 14.0 9.2 14.0 9.2 14.0 9.2 13.7 9.0 13.4 8.7 20.0˚CWB 28˚CDB TC SHC 11.5 7.3 11.5 7.3 11.5 7.3 11.5 7.3 11.5 7.3 11.5 7.3 11.5 7.3 11.5 7.3 11.5 7.3 11.5 7.3 11.5 7.3 11.5 7.3 11.5 7.3 11.5 7.3 11.3 7.2 11.1 6.9 14.4 9.2 14.4 9.2 14.4 9.2 14.4 9.2 14.4 9.2 14.4 9.2 14.4 9.2 14.4 9.2 14.4 9.2 14.4 9.2 14.4 9.2 14.4 9.2 14.4 9.2 14.4 9.2 14.1 9.0 13.8 8.7 9-5 -7 22.0˚CWB 30˚CDB TC SHC 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.0 7.1 11.7 6.8 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.0 8.9 14.6 8.6 24.0˚CWB 32˚CDB TC SHC 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.5 6.9 12.3 6.6 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 15.6 8.7 15.3 8.4 Heating capacity Unit size 007 009 012 015 Outdoor air temp. ˚CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.6 2.6 2.6 2.6 2.0 2.1 2.3 2.3 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.3 3.3 3.3 3.3 2.5 2.7 2.8 2.9 3.1 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.2 4.2 4.2 4.2 3.1 3.3 3.6 3.7 3.9 4.1 4.3 4.5 4.7 4.8 5.0 5.2 5.2 5.2 5.2 5.2 SHC : Sensible Heat Capacity (kW) Indoor air temp. ˚CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 1.5 1.5 1.5 1.4 1.6 1.6 1.6 1.5 1.7 1.7 1.7 1.6 1.8 1.8 1.7 1.7 1.9 1.9 1.8 1.8 2.0 2.0 1.9 1.9 2.1 2.0 2.0 1.9 2.2 2.1 2.1 2.0 2.3 2.2 2.2 2.1 2.4 2.3 2.3 2.2 2.5 2.4 2.4 2.3 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.0 1.9 1.9 1.8 2.1 2.1 2.0 1.9 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.1 2.4 2.4 2.3 2.3 2.6 2.5 2.4 2.4 2.7 2.6 2.6 2.5 2.8 2.7 2.7 2.6 2.9 2.9 2.8 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 2.9 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 2.5 2.4 2.3 2.3 2.6 2.6 2.5 2.4 2.8 2.7 2.7 2.6 2.9 2.8 2.7 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 3.0 3.3 3.3 3.2 3.1 3.5 3.4 3.3 3.3 3.7 3.6 3.5 3.4 3.8 3.7 3.6 3.5 3.9 3.9 3.8 3.7 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 3.1 3.0 2.9 2.9 3.3 3.2 3.1 3.0 3.5 3.4 3.3 3.2 3.6 3.5 3.4 3.3 3.8 3.7 3.6 3.5 4.0 3.9 3.8 3.7 4.2 4.1 4.0 3.9 4.4 4.3 4.2 4.1 4.6 4.5 4.4 4.2 4.7 4.6 4.5 4.4 4.9 4.8 4.7 4.6 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 9-5 -8 Heating capacity (cont.) Unit size 018 024 027 030 Outdoor air temp. ˚CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 5.0 5.3 5.7 5.8 6.2 6.5 6.8 7.1 7.4 7.7 8.0 8.3 8.3 8.3 8.3 8.3 5.6 6.0 6.4 6.6 7.0 7.3 7.7 8.0 8.4 8.7 9.0 9.4 9.4 9.4 9.4 9.4 6.3 6.7 7.1 7.3 7.7 8.1 8.5 8.9 9.3 9.7 10.0 10.4 10.4 10.4 10.4 10.4 Indoor air temp. ˚CDB 18.0 20.0 22.0 SHC SHC SHC 3.9 3.8 3.7 4.1 4.0 3.9 4.4 4.3 4.2 4.5 4.4 4.3 4.8 4.7 4.6 5.0 4.9 4.8 5.3 5.2 5.0 5.5 5.4 5.3 5.8 5.6 5.5 6.0 5.9 5.7 6.2 6.1 5.9 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 4.9 4.8 4.7 5.2 5.1 5.0 5.6 5.5 5.3 5.7 5.6 5.5 6.1 5.9 5.8 6.4 6.2 6.1 6.7 6.6 6.4 7.0 6.9 6.7 7.3 7.1 7.0 7.6 7.4 7.3 7.9 7.7 7.5 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 5.5 5.4 5.3 5.9 5.8 5.6 6.3 6.1 6.0 6.5 6.3 6.2 6.8 6.7 6.5 7.2 7.0 6.9 7.5 7.4 7.2 7.9 7.7 7.5 8.2 8.0 7.8 8.5 8.4 8.2 8.9 8.7 8.5 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 6.1 6.0 5.9 6.6 6.4 6.3 7.0 6.8 6.7 7.2 7.0 6.9 7.6 7.4 7.2 8.0 7.8 7.6 8.4 8.2 8.0 8.8 8.6 8.4 9.1 8.9 8.7 9.5 9.3 9.1 9.9 9.7 9.4 10.2 10.0 9.8 10.2 10.0 9.8 10.2 10.0 9.8 10.2 10.0 9.8 10.2 10.0 9.8 24.0 SHC 3.6 3.8 4.1 4.2 4.4 4.7 4.9 5.1 5.3 5.6 5.8 6.0 6.0 6.0 6.0 6.0 4.6 4.9 5.2 5.3 5.6 5.9 6.2 6.5 6.8 7.1 7.3 7.6 7.6 7.6 7.6 7.6 5.1 5.5 5.8 6.0 6.3 6.7 7.0 7.3 7.6 7.9 8.3 8.6 8.6 8.6 8.6 8.6 5.7 6.1 6.5 6.7 7.0 7.4 7.8 8.1 8.5 8.8 9.2 9.5 9.5 9.5 9.5 9.5 9-5 -9 Heating capacity (cont.) Unit size 036 048 Outdoor air temp. ˚CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 7.8 8.3 8.9 9.1 9.7 10.2 10.7 11.1 11.6 12.1 12.6 13.0 13.0 13.0 13.0 13.0 10.0 10.7 11.4 11.7 12.4 13.0 13.6 14.3 14.9 15.5 16.1 16.7 16.7 16.7 16.7 16.7 Indoor air temp. ˚CDB 18.0 20.0 22.0 SHC SHC SHC 7.7 7.5 7.3 8.2 8.0 7.8 8.7 8.5 8.3 9.0 8.8 8.6 9.5 9.3 9.1 10.0 9.8 9.5 10.5 10.2 10.0 10.9 10.7 10.5 11.4 11.2 10.9 11.9 11.6 11.3 12.3 12.1 11.8 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 9.8 9.6 9.4 10.5 10.3 10.0 11.1 10.9 10.7 11.5 11.2 11.0 12.1 11.9 11.6 12.8 12.5 12.2 13.4 13.1 12.8 14.0 13.7 13.4 14.6 14.3 14.0 15.2 14.9 14.5 15.8 15.4 15.1 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 24.0 SHC 7.2 7.6 8.1 8.3 8.8 9.3 9.7 10.2 10.6 11.0 11.5 11.9 11.9 11.9 11.9 11.9 9.1 9.7 10.4 10.7 11.3 11.9 12.4 13.0 13.6 14.1 14.7 15.2 15.2 15.2 15.2 15.2 9-5 -10 9-5-5. Fan characteristics In case of square duct flange of discharge section MMD-AP0121BH Standard air volume: 480m³/h 140 Hi gh Hi gh 120 tic pre 120 ss ure lim it 0P a) ic pre ure 1( nd ard sta tic pre ssu re (40 Pa ) (Hi gh Lo ) ws tat ic p res su re (H Sta igh nd ) ard pre ssu re (20 Pa ) (L ow ) 20 60 pr es Pa ) su re (4 0P a) (H igh sta ) tic pre ss ure (H igh Sta ) nd ard pre ure (20 Pa ) 20 0 300 600 (Lo w) 500 570 700 Air volume (m³/h) Standard air volume: 650m³/h Hig n tio ca pli p A Standard air volume: 780m³/h 140 Hig h h st atic it lim pre ssu re 2 (10 0P a) 0 Pa 80 rd s tatic pre ssu ) re ( 40 P a) ( Hig Low sta tic 40 nda rd p res pre ssu sur re ( h) Hig 60 Sta nda rd s pre ssu tatic (70 0P a) Pa) (40 Pa) ( Hig Low sta tic pre ssu nda rd pre ssu 20 ) re 1 pres sure Sta h) Low (10 80 e (2 20 atic re 40 Hig 0P a) ( e2 o ati h st Air volume limit (Min) 1 (7 External static pressure (Pa) ure Air volume limit (Max) ress sur lic p ic p res i nl Ap stat ic p t mi 100 High stat 120 100 Air volume limit (Min) 1( MMD-AP0181BH 120 External static pressure (Pa) re ss 480 140 Sta su sta tic Lo w 0P a) Long life filter 400 nda pr 70 rd 2( sta da 40 MMD-AP0151BH re (20 h) (Hi gh) Pa ) (Lo w) Long life filter Long life filter 0 400 gh es Air volume (m³/h) 60 Hi St an 80 ure 10 tic Long life filter 0 200 Sta ss Air volume limit (Max) 40 Air volume limit (Max) 60 Pa ) pre it 100 tat External static pressure (Pa) Sta ica Ap Hig 70 80 lim pl Air volume limit (Min) Ap pl ica t io n n tio ss Air volume limit (Min) External static pressure (Pa) 2( 10 hs sta sta tic 100 Standard air volume: 570m³/h 140 Air volume limit (Max) MMD-AP0071BH, AP0091BH 600 650 800 0 500 Air volume (m³/h) 700 Air volume (m³/h) *Note: “High” and “Low” refers to air flow. 9-5 -11 780 900 MMD-AP0241BH, AP0271BH Standard air volume: 1140m³/h 140 Stand ard s tatic p ressu Low s re (40 tatic p ressu Air volume limit (Max) Air volume limit (Min) Pa) Pa) (H igh) re (H Stand ard pre ssure (20 igh) High static press ure 1 (70 P a) 80 Stand a 60 rd sta tic pre ssure Air volume limit (Max) 1 (70 P a) (40 P a) (Hig h) Low static press ure (H igh) 40 Stand ard p Pa) (L ow) 20 ressu re (20 Pa) (L ow) 20 Long life filter 1000 1140 1200 Long life filter 0 900 1300 1100 Air volume (m³/h) MMD-AP0361BH MMD-AP0481BH Standard air volume: 1620m³/h 140 High static 120 press ure 2 t mi i nl (100 Standard air volume: 1980m³/h 140 Hig h st 120 Pa) A 100 pres sure 1 (70 Pa) Stan dard static press ure ( 40 P a) (H igh) Low static press ure (H igh) Air volume limit (Max) 80 High stat ic p ress ure 1 60 Sta nda rd s tatic dard sure stati c pre (40 ssur 0P a) (70 Pa) Pa) ( h) e (H igh) 40 pres sure (20 P a) (L (20 Pa) (L ow) ow) 20 (10 Hig Low dard pres pres sure Stan Stan re 2 80 Air volume limit (Min) static External static pressure (Pa) High Air volume limit (Min) ssu o ati lic pp 100 0 1200 pre i nl o ati A 40 atic t mi c li pp 1260 1300 Air volume (m³/h) 20 Long life filter Long life filter 1620 2000 0 1400 Air volume (m³/h) 1800 1980 Air volume (m³/h) *Note: “High” and “Low” refers to air flow. 9-5 -12 2200 Air volume limit (Max) 0 800 External static pressure (Pa) (100 tio lica 100 ressure 80 60 ure 2 p tatic p 40 press t Ap High s 60 static mi n li Air volume limit (Min) 100 High 120 External static pressure (Pa) on ati plic Ap it lim Standard air volume: 1260m³/h 140 High static press ure 2 (100 P a) 120 External static pressure (Pa) MMD-AP0301BH 9-5-6. Sound characteristics (NC-Curve) MMD-AP0071BH, AP0091BH Fan Tap Sound pressure level (dB (A)) H M L 30 28 26 Octave band sound pressure level (dB) 90 Microphone 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 H M 30 NC-30 L 20 NC-20 Audibility limits of continuous white level 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) MMD-AP0121BH MMD-AP0151BH Fan Tap Sound pressure level (dB (A)) H M L 31 29 27 Fan Tap Sound pressure level (dB (A)) 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 H 20 Audibility limits of continuous white level 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 H M L Audibility limits of continuous white level NC-20 10 63 125 250 500 1000 2000 4000 8000 63 MMD-AP0181BH Fan Tap Overall level dB(A) H M L 32 30 28 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 H M L Audibility limits of continuous white level NC-20 10 63 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band sound pressure level (dB) L 27 80 20 NC-20 M L 10 20 M 29 90 Octave band sound pressure level (dB) Octave band sound pressure level (dB) 90 H 31 8000 Octave band center frequency (Hz) 9-5 -13 8000 MMD-AP0241BH, AP0271BH Fan Tap Sound pressure level (dB(A)) MMD-AP0301BH H M L 33 31 29 Fan Tap Sound pressure level (dB(A)) 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continuous white level 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 NC-20 Audibility limits of continuous white level NC-20 10 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) Octave band center frequency (Hz) MMD-AP0361BH MMD-AP0481BH, AP0561BH Fan Tap Sound pressure level (dB(A)) H M L 36 34 32 Fan Tap Sound pressure level (dB(A)) 90 90 80 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 Octave band sound pressure level (dB) Octave band sound pressure level (dB) L 29 80 10 20 M 32 90 Octave band sound pressure level (dB) Octave band sound pressure level (dB) 90 H 34 NC-20 Audibility limits of continuous white level 10 H M L 38 36 32 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continuous white level NC-20 10 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 Octave band center frequency (Hz) Octave band center frequency (Hz) 9-5 -14 8000 9-5-7. Accessories Apperarance Standard accessories Part name Qty Installation Manual 1 Insulated pipe 2 Shape Use Part name Washer Qty Shape 8 For heat insulating pipe connecting section Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-5 -15 Use For hanging down the unit Optional accessories High Efficiency Filter 65 TCB-UFM11BFCE TCB-UFM21BFCE High Efficiency Filter 90 TCB-UFH51BFCE TCB-UFH61BFCE Standard filter and filter frame Filter Chamber TCB-FC281BE, TCB-FC501BE TCB-FC801BE, TCB-FC1401BE High Efficiency Filter 65 TCB-UFM11BE TCB-UFM21BE TCB-UFM31BE TCB-UFM41BE Filter kit for underside TCB-FK281BE, TCB-FK501BE TCB-FK801BE, TCB-FK1401BE High Efficiency Filter 90 TCB-UFH51BE TCB-UFH61BE TCB-UFH71BE TCB-UFH81BE Suction Canvas TCB-CA281BE, TCB-CA501BE TCB-CA801BE, TCB-CA1401BE Ceiling panel 9-5 -16 Name Model name Note TCB-UFM11BFCE High Efficiency Filter 65 (For rear suction) TCB-UFM11BFCE(2 pcs.) Dust collecting effect :65% (NBS Colorimentric method) TCB-UFM21BFCE TCB-UFM21BFCE(2 pcs.) TCB-UFH51BFCE High Efficiency Filter 90 (For rear suction) TCB-UFH51BFCE(2 pcs.) Dust collecting effect :90% (NBS Colorimentric method) TCB-UFH61BFCE TCB-UFH61BFCE(2 pcs.) TCB-FC281BE Filter Chamber (For rear suction) TCB-FC501BE For high efficiency filter TCB-FC801BE TCB-FC1401BE TCB-UFM11BE High Efficiency Filter 65 (For underside suction) TCB-UFM21BE Dust collecting effect :65% (NBS Colorimentric method) TCB-UFM31BE TCB-UFM41BE TCB-UFH51BE High Efficiency Filter 90 (For underside suction) TCB-UFH61BE Dust collecting effect :90% (NBS Colorimentric method) TCB-UFH71BE TCB-UFH81BE RBC-UD281PE(W) Ceiling panel (Half panel for underside suction) RBC-UD501PE(W) RBC-UD801PE(W) RBC-UD1401PE(W) TCB-CA281BE Suction Canvas (For underside suction) TCB-CA501BE TCB-CA801BE Adjustment height of the suction canvas is more 40mm and 100mm TCB-CA1401BE TCB-FK281BE TCB-FK501BE Filter kit for underside TCB-FK801BE Kit of underside prefilter & shielding plate of rear suction TCB-FK1401BE 9-5 -17 9-6-1. Specifications 50Hz Specifications (50Hz) Model name Cooling/Heating capacity (Note 1) MMD- AP0071SPH AP0091SPH AP0121SPH AP0151SPH AP0181SPH (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 Power supply Running current Electrical characteristics Power consumption Starting current 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) (A) 0.29 0.29 0.31 0.32 0.39 (kW) 0.039 0.039 0.043 0.045 0.054 (A) 0.51 0.51 0.54 0.56 0.68 23 23 690/600/520 780/680/580 Appearance Outer dimension Zinc hot dipping steel plate Height x Width x Depth (mm) (kg) Total weight 210/845/645 22 22 Heat exchanger Finned tube Soundproof/Heat-insulating material Polyethylene foam + Polyurethane foam Fan Centrifugal fan Standard air flow (High/Mid./Low) Fan unit 22 (m3/h) Motor 600/520/450 540/470/400 (W) 60 External static pressure (Factory setting) (Pa) 6 5 4 External static pressure (Pa) 6-16-31-46 (4steps) 5-15-30-40 (4steps) 4-14-29-44 (4steps) Air filter pressure loss (Pa) 4 5 6 Air filter Standard filter (Long life filter) Controller Connecting pipe Remote controller Gas side (mm) Liquid side (mm) Drain port Sound pressure level (Note 2) (High/Mid/Low) PMV Kit O / 9.5 O / 12.7 O / 6.4 (Nominal dia. mm) 25 (Polyvinyl chloride tube : External dia.32 Internal dia.25) Under air inlet (dB(A)) 36/33/30 38/35/32 39/36/33 40/38/36 Back air inlet (dB(A)) 28/26/24 29/27/25 32/30/28 33/31/29 Available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-6 -1 (Revised edition in 7.Apr.2006) 60Hz Specifications (60Hz) Model name Cooling/Heating capacity (Note 1) MMD- AP0071SPH AP0091SPH AP0121SPH AP0151SPH AP0181SPH (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 Power supply Electrical characteristics Running current Power consumption Starting current 1 phase 60Hz 220V (Separate power supply for indoor units is required.) (A) 0.27 0.27 0.30 0.31 0.37 (kW) 0.037 0.037 0.041 0.043 0.052 (A) 0.47 0.47 0.53 0.54 0.65 23 23 690/600/520 780/680/580 Appearance Outer dimension Zinc hot dipping steel plate Height x Width x Depth (mm) (kg) Total weight 210/845/645 22 22 22 Heat exchanger Finned tube Soundproof/Heat-insulating material Polyethylene foam + Polyurethane foam Fan Centrifugal fan Standard air flow (High/Mid./Low) Fan unit (m3/h) Motor 600/520/450 540/470/400 (W) 60 External static pressure (Factory setting) (Pa) 6 5 4 External static pressure (Pa) 6-16-31-46 (4steps) 5-15-30-45 (4steps) 4-14-29-44 (4steps) Air filter pressure loss (Pa) 4 5 6 Air filter Standard filter (Long life filter) Controller Connecting pipe Remote controller Gas side (mm) Liquid side (mm) Drain port Sound pressure level (Note 2) (High/Mid/Low) O / 9.5 O / 12.7 O / 6.4 25 (Polyvinyl chloride tube : External dia.32 Internal dia.25) (Nominal dia. mm) Under air inlet (dB(A)) 36/33/30 38/35/32 39/36/33 40/38/36 Back air inlet (dB(A)) 28/26/24 29/27/25 32/30/28 33/31/29 PMV Kit Available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-6 -2 (Revised edition in 7.Apr.2006) 9-6-2. Dimension MMD-AP0071SPH, AP0091SPH, AP0121SPH, AP0151SPH, AP0181SPH 210 21 21 803 (inside) 103 Air filter Refrigerant piping 511 645 19 4-O /4 67 20 21 168 (inside) 57 21 845 359 372 422 502 168 40 67 120 O /9 80 2 31 805 80 59 33 163 910 Fresh air inlet (Knock-out hole) Drain-up port Hanger plate Air inlet connecting flange (Field supply) 100 266.5 100 805 12.5 100 100 100 100 100 100 45.3 100 825 Wireless remote controller kit TCB-AX21E2 n=24 M5 (O/ 4.2 mounting hole) Weekly timer application RBC-AMT31E and RBC-EXW21E2 12.5 100 100 100 100 100 100 100 100 188.6 44.3 100 170 44.3 805 12.5 Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 12.5 100 Rearside 286.8 41.5 8.2 or less Underside 825 n=22 M5 (O/ 4.2 mounting hole) 9-6 -3 *China only 21 MMD-AP007SPH-C, AP0091SPH-C, AP0121SPH-C, AP0151SPH-C, AP0181SPH-C, MMD-AP0071SH-C, AP0091SH-C, AP0121SH-C, AP0151SH-C, AP0181SH-C 210 803 (inside) 21 21 Natural drain port 103 Refrigerant piping 80 511 645 359 372 422 502 805 910 59 40 168 120 67 80 31 146 O /9 2 4-O/ 4 19 67 20 21 168 (inside) 57 845 33 163 Fresh air inlet (Knock-out hole) Drain-up port (SPH model only) Hanger plate Air inlet connecting flange (Field supply) 100 266.5 100 805 12.5 286.8 41.5 8.2 or less Underside Wired remote controller RBC-AMT31E 12.5 100 100 100 100 100 100 100 45.3 100 825 Simple wired remote controller RBC-AS21E2 n=24 M5 (O/ 4.2 mounting hole) Wireless remote controller kit TCB-AX21E2 805 12.5 12.5 100 100 100 100 100 100 100 100 825 n=22 M5 (O/ 4.2 mounting hole) 9-6 -4 44.3 188.6 100 170 44.3 Rearside Weekly timer application RBC-AMT31E and RBC-EXW21E2 9-6-3. Wiring diagram MMD-AP0071SPH(SH), AP0091SPH(SH), AP0121SPH(SH), AP0151SPH(SH), AP0181SPH(SH) 9-6 -5 9-6-4. Sensible capacity table (MMD-AP***SPH) Cooling capacity Unit size 007 009 012 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 1.9 1.6 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 1.9 2.4 1.9 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.2 2.3 3.1 2.2 18.0°CWB 26°CDB TC SHC 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.1 1.8 2.0 1.7 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.7 2.1 2.6 2.0 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.4 2.5 3.4 2.4 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0°CWB 20.0°CWB 22.0°CWB 24.0°CWB 27°CDB 28°CDB 30°CDB 32°CDB TC SHC TC SHC TC SHC TC SHC 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.3 1.8 2.4 1.8 2.5 1.7 2.2 1.8 2.2 1.8 2.4 1.7 2.5 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.6 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.8 2.1 2.9 2.1 3.1 2.1 3.2 2.0 2.7 2.1 2.8 2.1 3.0 2.0 3.1 2.0 2.7 2.0 2.8 2.0 2.9 2.0 3.1 1.9 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.4 3.8 2.4 4.0 2.4 3.5 2.4 3.6 2.4 3.8 2.3 3.9 2.3 9-6 -6 Cooling capacity (cont.) Unit size 015 018 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.0 3.0 3.9 2.8 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.0 3.6 4.9 3.5 18.0°CWB 26°CDB TC SHC 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.3 3.1 4.2 3.0 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.3 3.8 5.2 3.7 Indoor air temp. 19.0°CWB 27°CDB TC SHC 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.5 3.2 4.4 3.1 4.3 3.0 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.6 3.9 5.5 3.8 5.4 3.7 20.0°CWB 28°CDB TC SHC 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.5 3.1 4.4 3.0 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.8 3.9 5.7 3.8 5.5 3.7 9-6 -7 22.0°CWB 30°CDB TC SHC 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.8 3.1 4.7 3.0 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.0 3.8 5.9 3.6 24.0°CWB 32°CDB TC SHC 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.0 3.0 4.9 2.9 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.3 3.7 6.1 3.6 Heating capacity Unit size 007 009 012 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.6 2.6 2.6 2.6 2.0 2.1 2.3 2.3 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.3 3.3 3.3 3.3 2.5 2.7 2.8 2.9 3.1 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.2 4.2 4.2 4.2 SHC : Sensible Heat Capacity (kW) Indoor air temp. °CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 1.5 1.5 1.5 1.4 1.6 1.6 1.6 1.5 1.7 1.7 1.7 1.6 1.8 1.8 1.7 1.7 1.9 1.9 1.8 1.8 2.0 2.0 1.9 1.9 2.1 2.0 2.0 1.9 2.2 2.1 2.1 2.0 2.3 2.2 2.2 2.1 2.4 2.3 2.3 2.2 2.5 2.4 2.4 2.3 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.0 1.9 1.9 1.8 2.1 2.1 2.0 1.9 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.1 2.4 2.4 2.3 2.3 2.6 2.5 2.4 2.4 2.7 2.6 2.6 2.5 2.8 2.7 2.7 2.6 2.9 2.9 2.8 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 2.9 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 2.5 2.4 2.3 2.3 2.6 2.6 2.5 2.4 2.8 2.7 2.7 2.6 2.9 2.8 2.7 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 3.0 3.3 3.3 3.2 3.1 3.5 3.4 3.3 3.3 3.7 3.6 3.5 3.4 3.8 3.7 3.6 3.5 3.9 3.9 3.8 3.7 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 9-6 -8 Heating capacity (cont.) Unit size 015 018 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.1 3.3 3.6 3.7 3.9 4.1 4.3 4.5 4.7 4.8 5.0 5.2 5.2 5.2 5.2 5.2 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 Indoor air temp. °CDB 18.0 20.0 22.0 SHC SHC SHC 3.1 3.0 2.9 3.3 3.2 3.1 3.5 3.4 3.3 3.6 3.5 3.4 3.8 3.7 3.6 4.0 3.9 3.8 4.2 4.1 4.0 4.4 4.3 4.2 4.6 4.5 4.4 4.7 4.6 4.5 4.9 4.8 4.7 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 3.9 3.8 3.7 4.1 4.0 3.9 4.4 4.3 4.2 4.5 4.4 4.3 4.8 4.7 4.6 5.0 4.9 4.8 5.3 5.2 5.0 5.5 5.4 5.3 5.8 5.6 5.5 6.0 5.9 5.7 6.2 6.1 5.9 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 24.0 SHC 2.9 3.0 3.2 3.3 3.5 3.7 3.9 4.1 4.2 4.4 4.6 4.8 4.8 4.8 4.8 4.8 3.6 3.8 4.1 4.2 4.4 4.7 4.9 5.1 5.3 5.6 5.8 6.0 6.0 6.0 6.0 6.0 9-6 -9 9-6-5. Fan characteristics MMD-AP0071SPH MMD-AP0091SPH MMD-AP0121SPH Standard air volume : 540m3/h Standard air volume : 600m3/h 60 60 50 Upper limit of external static pressure(35Pa) High (35Pa) 40 Lower limit of external static pressure (50Pa) Low (50Pa) Upper limit of external static pressure(20Pa) 30 High (20Pa) 20 Upper limit of external static pressure(10Pa) Low (35Pa) Lower limit of external static pressure (35Pa) External static pressure (Pa) External static pressure (Pa) 50 High (50Pa) High (50Pa) Upper limit of external static pressure(50Pa) Upper limit of external static pressure(50Pa) High (35Pa) 40 Low (50Pa) Lower limit of external static pressure (50Pa) Upper limit of external static pressure(35Pa) 30 High (20Pa) Low (35Pa) 20 Upper limit of external static pressure(20Pa) Lower limit of external static pressure (35Pa) High (10Pa) High (10Pa) 10 Low (20Pa) Upper limit of external static pressure(10Pa) Lower limit of external static pressure (20Pa) Low (10Pa) 0 300 400 Low (20Pa) 10 500 600 0 300 700 400 Air Volume (m3/h) 500 600 MMD-AP0181SPH Standard air volume : 690m3/h High (50Pa) High (50Pa) Upper limit of external static pressure(50Pa) 50 Upper limit of external static pressure(35Pa) Lower limit of external static pressure (50Pa) Low (50Pa) High (20Pa) 20 Low (35Pa) Upper limit of external static pressure(20Pa) Upper limit of external static pressure(10Pa) 0 400 500 Upper limit of external static pressure(50Pa) High (35Pa) Lower limit of external static pressure (35Pa) External static pressure (Pa) External static pressure (Pa) 50 10 Standard air volume : 780m3/h 60 60 30 700 Air Volume (m3/h) MMD-AP0151SPH 40 Lower limit of external static pressure (20Pa) Low (10Pa) High (35Pa) 40 Low (50Pa) 30 20 10 Low (20Pa) Lower limit of external static pressure (20Pa) 0 400 Air Volume ( m3 Upper limit of external static pressure(20Pa) Lower limit of external static pressure (35Pa) Upper limit of external static pressure(10Pa) Low (20Pa) Low (10Pa) Low (10Pa) 700 High (20Pa) Low (35Pa) High (10Pa) 600 Lower limit of external static pressure (50Pa) Upper limit of external static pressure(35Pa) 800 500 High (10Pa) 600 700 Air Volume (m3/h) /h) 9-6 -10 800 Lower limit of external static pressure (20Pa) 900 (Filter attached) MMD-AP0071SPH MMD-AP0091SPH MMD-AP0121SPH Standard air volume : 540m3/h Standard air volume : 600m3/h 60 60 High (50Pa) High (50Pa) Upper limit of external static pressure(50Pa) 50 50 Lower limit of external static pressure (50Pa) Upper limit of external static pressure(50Pa) Lower limit of externa static pressure (50Pa) Upper limit of external static pressure(35Pa) 30 Low (50Pa) Lower limit of external static pressure (35Pa) Low (35Pa) 20 High (20Pa) Upper limit of external static pressure(20Pa) External static pressure (Pa) External static pressure (Pa) Low (50Pa) 40 40 Upper limit o external static pressure(35Pa) 30 Low (35Pa) Upper limit o external static pressure(20Pa) 20 High (20Pa) Lower limit of external static pressure (20Pa) Lower limit of extern static pressure (20Pa) Low (20Pa) Low (20Pa) 10 10 Upper limit of external static pressure(10Pa) 0 300 High (10Pa) Upper limit o external static pressure(10Pa) High (10Pa) Standard filter pressure loss Low (10Pa) 400 500 600 700 400 500 600 700 Air Volume (m3/h) MMD-AP0151SPH MMD-AP0181SPH Standard air volume : 690m3/h 60 Standard air volume : 780m3/h 60 High (50Pa) High (50Pa) Upper limit of external static pressure(50Pa) Upper limit of external static pressure(50Pa) 50 50 Upper limit of external static pressure(35Pa) Lower limit of external static pressure (50Pa) Lower limit of external static pressure (35Pa) Low (50Pa) 30 Upper limit of external static pressure(20Pa) High (20Pa) Low (35Pa) 20 High (10Pa) Upper limit of external static pressure(10Pa) External static pressure (Pa) 40 Lower limit of external static pressure (50Pa) Upper limit of external static pressure(35Pa) High (35Pa) External static pressure (Pa) Standard filter pressure loss Low (10Pa) 0 300 Air Volume (m3/h) 10 Lower limit of external static pressure (35Pa) High (35Pa) 40 Low (50Pa) Lower limit of external static pressure (35Pa) High (35Pa) 30 Low (35Pa) 20 Lower limit of externa static pressure (20Pa) Upper limit of external static pressure(20Pa) Low (20Pa) 10 High (20Pa) Lower limit of external static pressure (20Pa) Upper limit of external static pressure(10Pa) High (10Pa) Low (20Pa) Low (10Pa) 0 400 Standard filter pressure loss 500 600 700 800 0 400 Air Volume (m3/h) Standard filter pressure loss Low (10Pa) 500 600 700 Air Volume (m3/h) 9-6 -11 800 900 CHINA model MMD-AP0071SPH-C, SH-C MMD-AP0091SPH-C, SH-C Standard air volume : 540m 3/h 60 High (50Pa) Upper limit of external static pressure(50Pa) 40 High (35Pa) Lower limit of external static pressure (50Pa) Low (50Pa) Upper limit of external static pressure(35Pa) 30 High (20Pa) Upper limit of external static pressure(20Pa) 20 Low (35Pa) Lower limit of external static pressure (35Pa) static Upper limit of external static pressure(35Pa) pressure (Pa ) 50 External pressure (Pa) s tatic Standard air volume : 600m 3/h 60 High (50Pa) Upper limit of external static pressure(50Pa) 50 External MMD-AP0121SPH-C, SH-C 0 300 Upper limit of external static pressure(35Pa) 20 Upper limit of external static pressure(20Pa) 500 Lower limit of external static pressure (50Pa) High (20Pa) Low (35Pa) Lower limit of external static pressure (35Pa) High (10Pa) Lower limit of external static pressure (20Pa) Low (10Pa) 400 30 10 Low (20Pa) Upper limit of external static pressure(10Pa) Low (50Pa) Low (20Pa) High (10Pa) 10 High (35Pa) 40 600 0 300 700 Lower limit of external static pressure (20Pa) Upper limit of external static pressure(10Pa) Low (10Pa) 400 500 600 Air Volume ( m3/h) Air Volume ( m3/h) MMD-AP0151SPH-C, SH-C MMD-AP0181SPH-C, SH-C Standard air volume : 690m 3/h 60 Standard air volume : 780m 3/h 60 High (50Pa) Upper limit of external static pressure(50Pa) 50 40 Low (50Pa) Lower limit of external static pressure (50Pa) 30 High (20Pa) 20 Lower limit of extern static pressure (35Pa) Low (35Pa) High (35Pa) 40 Low (50Pa) Lower limit of external static pressure (50Pa) 30 Low (35Pa) 20 Upper limit of external static pressure(20Pa) High (20Pa) Lower limit of extern static pressure (35Pa) High (10Pa) Upper limit of external static pressure(20Pa) 0 400 Upper limit of external static pressure(35Pa) pressure ( Pa) High (35Pa) Ext ernal static s tatic pressure ( Pa) Upper limit of external static pressure(35Pa) External High (50Pa) Upper limit of external static pressure(50Pa) 50 10 700 Upper limit of external static pressure(10Pa) 500 High (10Pa) 10 Low (20Pa) Low (20Pa) Lower limit of external static pressure (20Pa) Upper limit of external static pressure(10Pa) Low (10Pa) 600 700 0 400 800 Air Volume ( m3/h) 500 Lower limit of exte static pressure (20Pa) Low (10Pa) 600 700 800 900 Air Volume ( m3/h) 9-6 -12 (Revised edition in 7.Apr.2006) 9-6-6. Sound characteristics (NC-Curve) MMD-AP0071SPH/SH , MMD-AP0091SPH/SH Measuring location 2m 1m Duct Duct Air outlet Rear air intake Air inlet Center 1.5m Microphone External static pressure 10Pa H M L 28 26 24 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 30 NC-30 H M 20 Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa M L 29 27 25 50 NC-50 40 NC-40 30 NC-30 H M 20 L NC-20 L NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 63 8000 125 External static pressure 35Pa Fan tap Sound pressure level (dB(A)) 500 1000 2000 4000 8000 External static pressure 50Pa H M L 30 28 26 Fan tap Sound pressure level (dB(A)) 70 60 60 50 NC-50 40 NC-40 30 NC-30 H M L Octave band sound pressure level (dB) 70 20 250 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band sound pressure level (dB) H H M L 32 29 27 50 NC-50 40 NC-40 H 30 NC-30 M L 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 Octave band center frequency (Hz) 125 250 500 1000 2000 Octave band center frequency (Hz) 9-6 -13 4000 8000 MMD-AP0121SPH/SH Measuring location 2m 1m Duct Duct Air outlet Rear air intake Air inlet Center 1.5m Microphone External static pressure 10Pa H M L 29 27 25 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 30 H NC-30 M Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa L 20 H M L 30 28 26 50 NC-50 40 NC-40 H 30 NC-30 M L 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 125 Octave band center frequency (Hz) External static pressure 35Pa H M L 31 29 27 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H 30 500 1000 2000 4000 8000 External static pressure 50Pa NC-30 M Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) 250 Octave band center frequency (Hz) H M L 32 30 28 50 NC-50 40 NC-40 H 30 NC-30 M L L 20 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 Octave band center frequency (Hz) 125 250 500 1000 2000 Octave band center frequency (Hz) 9-6 -14 4000 8000 MMD-AP0151SPH/SH Measuring location 2m 1m Duct Duct Air outlet Air inlet Rear air intake Center 1.5m Microphone External static pressure 10Pa H M L 32 30 28 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 30 H NC-30 M Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa M L 33 31 29 50 NC-50 40 NC-40 30 L 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 10 8000 63 125 Octave band center frequency (Hz) 500 M L 34 32 30 Fan tap Sound pressure level (dB(A)) 70 60 60 50 NC-50 40 NC-40 H NC-30 M Octave band sound pressure level (dB) 70 M L 35 33 31 NC-50 40 NC-40 H 30 500 NC-30 M 20 NC-20 Approximate threshold of hearing for continuous noise 10 250 8000 50 Approximate threshold of hearing for continuous noise 125 4000 L NC-20 63 2000 H L 20 1000 External static pressure 50Pa H 30 250 Octave band center frequency (Hz) External static pressure 35Pa Fan tap Sound pressure level (dB(A)) NC-30 H M L 20 Octave band sound pressur level (dB) H 1000 2000 4000 8000 10 63 Octave band center frequency (Hz) 125 250 500 1000 2000 Octave band center frequency (Hz) 9-6 -15 4000 8000 MMD-AP0181SPH/SH Measuring location 2m 1m Duct Duct Air outlet Rear air intake Air inlet Center 1.5m Microphone External static pressure 10Pa H M L 33 31 29 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H 30 NC-30 M Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa H M L 34 32 30 50 NC-50 40 NC-40 H 30 M L NC-30 L 20 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 125 Octave band center frequency (Hz) External static pressure 35Pa 500 1000 2000 4000 8000 External static pressure 50Pa H M L 35 33 31 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H 30 NC-30 M L Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) 250 Octave band center frequency (Hz) 20 H M L 36 34 32 50 NC-50 40 NC-40 H 30 NC-30 M L 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 Octave band center fequency (Hz) 125 250 500 1000 2000 Octave band center frequency (Hz) 9-6 -16 4000 8000 2m MMD-AP0071SPH/SH , MMD-AP0091SPH/SH Duct Air outlet Measuring location Center 1.5m Under air intake Air inlet Microphone External static pressure 10Pa H M L 36 33 30 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H M 30 NC-30 L Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa 20 H M L 37 34 31 50 NC-50 40 NC-40 H M 30 NC-30 L 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 125 Octave band center frequency (Hz) External static pressure 35Pa H M L 39 36 33 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H M 30 500 1000 2000 4000 8000 External static pressure 50Pa NC-30 L 20 Octave band sound pressure level (dB) Octave band soune pressure level (dB) Fan tap Sound pressure level (dB(A)) 250 Octave band center frequency (Hz) H M L 41 38 35 50 NC-50 H M 40 NC-40 L 30 NC-30 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 Octave band center frequency (Hz) 125 250 500 1000 2000 Octave band center frequency (Hz) 9-6 -17 4000 8000 2m MMD-AP0121SPH/SH Measuring location Duct Air outlet Center 1.5m Under air intake Air inlet Microphone External static pressure 20Pa External static pressure 10Pa Fan tap Sound pressure level (dB(A)) H M L 38 35 32 Fan tap Sound pressure level (dB(A)) 70 L 39 36 33 60 50 NC-50 40 NC-40 H M 30 NC-30 L Octave band sound pressure level (dB) Octave band sound pressure level (dB) M 70 60 20 50 NC-50 40 M 30 NC-20 Approximate threshold of hearing for continuous noise 10 125 250 500 1000 2000 4000 10 8000 63 125 Octave band center frequency (Hz) M L 41 38 35 Fan tap Sound pressure level (dB(A)) 70 60 60 50 NC-50 H NC-40 M L NC-30 20 Octave band sound pressure frequency (dB) 70 30 4000 8000 H M L 43 40 37 NC-50 H 40 NC-40 M L 30 NC-30 NC-20 Approximate threshold of hearing for continuous noise 10 250 2000 50 Approximate threshold of hearing for continuous noise 125 1000 20 NC-20 63 500 External static pressure 50Pa H 40 250 Octave band center frequency (Hz) External static pressure 35Pa Fan tap Sound pressure level (dB(A)) NC-30 L 20 NC-20 63 NC-40 H Approximate threshold of hearing for continuous noise Octave band sound pressure level (dB) H 500 1000 2000 4000 10 8000 63 Octave band center frequency (Hz) 125 250 500 1000 2000 Octave band center frequency (Hz) 9-6 -18 4000 8000 MMD-AP0151SPH/SH 2m Measuring location Duct Air outlet Under air intake Center 1.5m Air inlet Microphone External static pressure 10Pa H M L 39 36 33 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H M 30 NC-30 L Octave band sound frequency level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa 20 H M L 40 37 34 50 NC-50 40 NC-40 H M 30 NC-30 L 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 125 External static pressure 35Pa H M L 41 38 35 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 H 40 NC-40 M L 30 500 1000 2000 4000 8000 External static pressure 50Pa NC-30 20 Octave band sound frequency level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) 250 Octave band center frequency (Hz) Octave band center frequency (Hz) H M L 43 40 37 50 NC-50 H 40 NC-40 M L 30 NC-30 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 Octave band center frequency (Hz) 125 250 500 1000 2000 Octave band center frequency (Hz) 9-6 -19 4000 8000 MMD-AP0181SPH/SH 2m Measuring location Duct Air outlet Under air intake Center 1.5m Air inlet Microphone External static pressure 10Pa H M L 40 38 36 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H M 30 NC-30 L Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa H M L 42 40 37 50 NC-50 H 40 NC-40 M L 30 NC-30 20 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 63 8000 125 External static pressure 35Pa 500 1000 2000 4000 8000 External static pressure 50Pa H M L 43 41 38 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 H 40 NC-40 M L 30 NC-30 Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) 250 Octave band center frequency (Hz) Octave band center frequency (Hz) 20 H M L 44 42 39 50 NC-50 H 40 NC-40 M L 30 NC-30 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 Octave band center frequency (Hz) 125 250 500 1000 2000 Octave band center frequency (Hz) 9-6 -20 4000 8000 9-6-7. Accessories Apperarance Standard accessories Qty Shape Installation Manual 1 — Insulating pipe 2 Washer 8 Hose band 1 For connecting drain pipe Flexible hose 1 For centering the drain pipe Heat insulator 1 For sealing the wire connection opening Part name Use (Be sure to hand over to customer) For insulating of pipe connecting section M10 x Ø34 For hanging down unit Optional accessories Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-6 -21 9-7-1. Specifications 50Hz Specifications (50Hz) Model name Cooling/Heating capacity (Note 1) MMD- AP0181H AP0241H AP0271H AP0361H AP0481H (kW) 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 Power supply (A) 0.81 1.35 1.63 1.84 (kW) 0.184 0.299 0.368 0.414 Power factor (%) 99 96 Starting current (A) 1.3 3.5 Running current Electrical characteristics 1 phase 50Hz 220V (220-240V) (Separate power supply for indoor units is required.) Power consumption Appearance Outer dimension 4.1 Height x Width x Depth (mm) (kg) 380 x 850 x 660 50 380 x 1,200 x 660 52 Heat exchanger 56 67 1,600 2,100 Finned tube Soundproof/Heat-insulating material Non-flammable insulation Fan Centrifugal fan (m3/h) Standard air flow Motor 900 1,320 (W) 260 160 External static pressure (Factory setting) (Pa) 137 External static pressure (Pa) 68.6-137-196 Air flow limit Lower limit/Upper limit (m3/h) 720/1,080 1,280/1,920 1,060/1,580 Air filter 1,680/2,520 Option or field supply Controller Connecting pipe 4.8 Zinc hot dipping steel plate Total weight Fan unit 98 Remote controller Gas side (mm) O / 12.7 O / 15.9 Liquid side (mm) O / 6.4 O / 9.5 Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) 25 (One side of male screw) 37 40 PMV Kit Not available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O O O 9-7 -1 O 60Hz Specifications (60Hz) Model name Cooling/Heating capacity (Note 1) MMD- AP0181H AP0241H AP0271H AP0361H AP0481H (kW) 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 Power supply (A) 0.92 1.80 2.07 2.26 (kW) 0.198 0.385 0.450 0.490 Power factor (%) 98 97 Starting current (A) 1.30 3.40 Running current Electrical characteristics 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Power consumption Appearance 3.90 (mm) (kg) Total weight 380 x 850 x 660 50 380 x 1,200 x 660 52 Heat exchanger 56 67 1,600 2,100 Finned tube Soundproof/Heat-insulating material Non-flammable insulation Fan Centrifugal fan (m3/h) Standard air flow Motor 900 1,320 (W) 260 160 External static pressure (Factory setting) (Pa) 137 External static pressure (Pa) 68.6-137-196 Air flow limit Lower limit/Upper limit (m3/h) 720/1,080 1,280/1,920 1,060/1,580 Air filter 1,680/2,520 Option or field supply Controller Connecting pipe 4.35 Zinc hot dipping steel plate Outer Height x Width x Depth dimension Fan unit 99 Remote controller Gas side (mm) O / 12.7 O / 15.9 Liquid side (mm) O / 6.4 O / 9.5 Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) 25 (One side of male screw) 37 40 PMV Kit Not available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 9-7 -2 O O O 9-7-2. Dimension MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H MMD-AP0181H to AP0361H MMD-AP0481H 710 (Hanging bolt mounting pitch 800) Hole for hanging bolt (4-O / 12 x 72) Power supply/ communication piping port (O / 26) (Under electric parts box) Electric parts box Hole for hanging bolt (4-O / 12 x 72) Power supply/ communication piping port (O / 26) (Under electric parts box) Refrigerant pipe connecting port (Liquid side O / A) Refrigerant pipe connecting port (Gas side O / B) Electric parts box Refrigerant pipe connecting port (Liquid side O / 9.5) Refrigerant pipe connecting port (Gas side O / 15.9) Screw hole for duct mounting (6-M6) Air suction port Drain pipe connecting port (VP25) Screw hole for duct mounting (8-M6) Air suction port Drain pipe connectingport (VP25) Z view Z view Air discharge port AP0181H to AP0271H type Screw hole for duct mounting (8-M6) Air discharge port Screw hole for duct mounting (6-M6) Air discharge port AP0361H type Model MMDAP0181H AP0241H, AP0271H, AP0361H, AP0481H A 6.4 9.5 B 12.7 15.9 Service space Service space 2.7 Check port 600 500 mm or more Space required for installation and servicing *1 600 mm or more 4 Wired remote controller RBC-AMT31E Wireless remote controller kit TCB-AX21E2 Simple wired remote controller RBC-AS21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 120 Screw hole for duct mounting (4-M6) Z view 120 16 Note: All dimensions are in mm. 9-7 -3 Indoor unit Earth screw Closed end connector WHI RED S(N) F CN067 (BLK) RY007 1 2 1 2 4 43F1 3 5 43F1 1 2 3 4 1 2 3 4 GRY FM Remote controller 1 2 1 2 CN1 (WHI) A B 1 2 3 1 3 RC U1 U2 OC U1 U2 EMG 1 2 CN044 CN040 CN041 (BRW) (BLU) (BLU) Outdoor unit YEL Closed end connector Fuse T5.0A CN066 (WHI) RED RED 6 Flow selector unit earth screw TR 1 2 1 1 2 2 3 3 RED RC L 3 3 2 1 1 F4 F3 F2 X Y F1 WHI MCC-1401 DP LM CN074 (WHI) RY001 1 2 3 1 2 3 1 2 1 2 CN075 CN061 (WHI) (YEL) CN032 (WHI) CN060 (WHI) CN082 (BLU) CN081 (BLK) TR 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) Sub P.C. board MCC-1520 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) 6 5 4 3 2 1 Motor over heating protection switch WHI GRY RED BLK Wired for MMD-AP0481 only (BRN Wire) 49F ORN BRN BLU 5 2 1 3 4 6 5 2 1 3 4 6 Parts name Fan motor Running capacitor Transformer Indoor temp sensor Temp sensor Fan motor control relay Flap motor control relay Drain control relay Pulse Motor Valve Fuse Fan motor control relay Drain pump motor Float switch PMV Symbol FM RC TR TA TC1,TC2,TCJ RY005~007 RY001 RY002 PMV F 43F1 Sold DM separately FS 6 5 4 3 2 1 1 2 3 4 5 1 Filter 2 1 EXCT 2 CN073 (RED) CN070 (WHI) 1 2 PNL 3 CN080 (GRN) 1 2 3 CN100 1 2 3 (BRN) TC1 1 2 3 4 5 6 1 2 3 4 5 6 1 2 1 2 3 4 5 6 Option 1 2 3 4 5 6 T10 Fan drive Power supply circuit 1 2 1 2 TC2 CN104 CN102 CN101 (YEL) (RED) (BLK) 1 2 1 2 TCJ Indoor control P.C. board FS CN030 (RED) 1 2 3 1 2 3 TA 1. indicates the terminal block, the letter inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring on site. indicates the control P.C. board. 3. 4. When installing a drain pump, Remove CN030 connector and connect float switch. 5 . A part is connected to the terminal block. When a change is required due to the outside static pressure at site, check the terminal No. and lead colour of the fan motor in the below diagram and then change the lead wire as indicated by the arrow mark ( ), 6. Pay attention when changing static pressure because the outside static pressure of H tap in 50 or 60Hz. Network adaptor (Option) 1 2 CN03 1 2 (RED) CN01 1 2 (WHI) 1 2 DP 1 2 3 (BLU) 1 2 3 (GRN) 1 2 3 CN068 1 2 3 CN033 RY002 UL 1 2 3 4 5 CN050 (WHI) RY005 RY006 M CN02 (BLU) H FAN 9 8 7 6 4 2 CN083(WHI) 9 8 7 6 5 4 3 2 1 7 RY004 P301 43F1 1 1 CN309 2 2 (YEL) 3 3 3 CN304 (GRY) 2 1 (BLK) T10A,250V~ Power supply Single phase 220-240V 50Hz 220V 60Hz R(L) RED RED : RED WHI : WHITE YEL :YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN 8 BLU WHI (Option) ORN Color indication WHI RED GRY WHI RED BLK 9-7 -4 BRN Spark killer 9-7-3. Wiring diagram Model: MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H Symbol FM RC TR TA TC1,TC2,TC3 RY005~007 RY001 RY002 PMV F1~3 43F1,43F2 DM FS R(L) S(N) WHI Power supply single phase 220-240V 50Hz 220V 60Hz Indoor unit earth screw RED WHI RED Parts name Fan motor Running capacitor Transformer Indoor temp sensor Temp sensor Fan motor control relay Louver control relay Drain control relay Pulse motor valve Fuse for fan motor Fan motor control relay Drain pump motor Float switch RED : RED WHI : WHITE YEL :YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Closed-end connector Motor over heating protection switch 49F Color indication WHI GRY RED BLK YEL BLU ORN 43F2 WHI RED 7 8 WHI 43F1 8 S.K WHI 8 AC IN S.K F3 F2 1 2 3 3 1 1 F1 WHI RED 3 3 1 1 3 1 P301 (BLK) 43F1 3 B FAN3 1 2 3 4 4P 1 2 3 4 (RED) 5 RED FM3 RC F1 ORW F2 F3 X Y F4 CN03(RED) 1 2 1 2 CN074 1 (WHI) 1 4 6 43F2 MCC-1401 FAN2 1 2 3 4 4P 1 2 3 4 (BLU) 3 3 FM2 F1 ORW RC LM CN033 3 (GRN) Indicates the terminal bolock, Letter on the inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring on site. 3. indicate the control p.c. board. 4. When fitting a drain pump remove CN030 connector and connect float switch. 1. Closed-end connector 3 5 A RY001 DP 3 CN068 3 (BLU) 1 Network Adapter (Option) CN01(WHI) CN02 (BLU) 1 2 1 2 1 2 3 4 5 3 3 2 1 1 1 1 RY002 UL 1 1 CN050 (WHI) RY005 L 3 3 RY006 M H 1 2 1 2 CN1 Remote Controller RED 43F2 Outdoor unit U1 U2 T10.0A, 250V~ 5 CN041 (BLU) RY007 5 5 7 7 1 2 1 2 3 1 2 CO 1 3 RC U1 U2 Line Filter 1 2 EMG TR CN044 CN040 (BRW) (BLU) CN066 (WHI) CN067 (BLK) T5.0A 250V~ FUSE (YEL) CN309 (GRY) CN304 RY004 T10.0A, 250V~ T10.0A, 250V~ RED RED RED Sold separately WHI FAN CN083 9 (WHI) 9 BLK Fan motor inside wiring diagram BLU WHI RED GRY YEL BLU WHI RED GRY BLK Spark Killer YEL 7 BLU 7 ORN WHI RED GRY WHI RED GRY 6 YEL RED 3 3 F2 F3 1 2 1 2 TC2 4 6 43F1 FAN1 1 2 3 4 4P 1 2 3 4 (WHI) CN082 (BLU) OPTION FAN DRIVE FM1 F1 ORW RC F2 F3 F4 Termi- Fan motor wiring nal No. F1 YEL F2 BLU F3 ORN 1 2 3 4 5 6 CN060 (WHI) 6 5 4 3 2 1 5 2 1 3 4 6 5 2 1 3 4 6 PMV Static pressure Pa 69(7) (mmAg) 137(14) 196(20) 6 5 4 3 2 1 1 FILTER 2 1 2 3 4 5 1 2 CN032 (WHI) Setting from factory Note board unit MCC-1403 Control P.C. 1 EXCT for Indoor 2 1 2 PNL 3 CN081 (BLK) CN070 (WHI) CN073 (RED) CN100 (BRW) CN080 (GRN) 1 3 1 2 3 TC1 5. A Position is connected to the terminal block when there is a change to static pressure. change the lead wire of arrow position after checking the terminal number as per figure and the lead wire's checking fan motor. 6. When setting to the high tap, take care as the static pressures are different at50Hz and 60Hz. F4 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (YEL) TR CN061 (YEL) 1 2 3 4 5 6 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) Sub P.C. board MCC-1520 1 2 1 2 TCJ CN104 CN102 CN101 (YEL) (RED) (BLK) 1 2 1 2 TA Control P.C. board for Indoor unit MCC-1403 CN030 (RED) FS 1 1 CN075 (WHI) 1 2 3 4 5 6 1 2 3 4 5 6 Power supply circuit BLU DM ORN WHI RED GRY WHI RED GRY (Option) YEL RED BLU 9-7 -5 ORN RED Model: MMD-AP0721H, AP0961H 9-7-4. Sensible capacity table (MMD-AP***H) Cooling capacity Unit size 018 024 027 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.0 3.7 4.9 3.6 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.3 4.6 6.2 4.4 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.1 5.0 7.0 4.8 18.0°CWB 26°CDB TC SHC 5.4 4.0 5.4 4.0 5.4 4.0 5.4 4.0 5.4 4.0 5.4 4.0 5.4 4.0 5.4 4.0 5.4 4.0 5.4 4.0 5.4 4.0 5.4 4.0 5.4 4.0 5.4 4.0 5.3 3.9 5.2 3.8 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.9 5.0 6.7 4.9 6.6 4.7 7.8 5.4 7.8 5.4 7.8 5.4 7.8 5.4 7.8 5.4 7.8 5.4 7.8 5.4 7.8 5.4 7.8 5.4 7.8 5.4 7.8 5.4 7.8 5.4 7.8 5.4 7.8 5.4 7.6 5.3 7.4 5.1 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0°CWB 20.0°CWB 22.0°CWB 24.0°CWB 27°CDB 28°CDB 30°CDB 32°CDB TC SHC TC SHC TC SHC TC SHC 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.6 4.0 5.8 4.0 6.1 4.0 6.4 3.9 5.5 3.9 5.7 3.9 6.0 3.9 6.3 3.8 5.4 3.8 5.5 3.8 5.9 3.7 6.1 3.6 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.1 5.0 7.3 5.0 7.7 5.0 8.1 4.8 7.0 4.9 7.2 4.9 7.6 4.9 7.9 4.7 6.8 4.7 7.0 4.7 7.4 4.7 7.8 4.6 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 8.0 5.4 8.2 5.4 8.7 5.3 9.1 5.2 7.8 5.3 8.1 5.3 8.5 5.2 8.9 5.1 7.7 5.1 7.9 5.1 8.4 5.0 8.8 4.9 9-7 -6 Cooling capacity (cont.) Unit size 036 048 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.0 7.2 9.8 6.9 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.5 8.8 12.2 8.4 18.0°CWB 26°CDB TC SHC 10.9 7.8 10.9 7.8 10.9 7.8 10.9 7.8 10.9 7.8 10.9 7.8 10.9 7.8 10.9 7.8 10.9 7.8 10.9 7.8 10.9 7.8 10.9 7.8 10.9 7.8 10.9 7.8 10.6 7.7 10.4 7.4 13.6 9.5 13.6 9.5 13.6 9.5 13.6 9.5 13.6 9.5 13.6 9.5 13.6 9.5 13.6 9.5 13.6 9.5 13.6 9.5 13.6 9.5 13.6 9.5 13.6 9.5 13.6 9.5 13.3 9.3 13.0 9.0 Indoor air temp. 19.0°CWB 27°CDB TC SHC 11.2 7.8 11.2 7.8 11.2 7.8 11.2 7.8 11.2 7.8 11.2 7.8 11.2 7.8 11.2 7.8 11.2 7.8 11.2 7.8 11.2 7.8 11.2 7.8 11.2 7.8 11.2 7.8 11.0 7.6 10.8 7.3 14.0 9.5 14.0 9.5 14.0 9.5 14.0 9.5 14.0 9.5 14.0 9.5 14.0 9.5 14.0 9.5 14.0 9.5 14.0 9.5 14.0 9.5 14.0 9.5 14.0 9.5 14.0 9.5 13.7 9.3 13.4 8.9 20.0°CWB 28°CDB TC SHC 11.5 7.8 11.5 7.8 11.5 7.8 11.5 7.8 11.5 7.8 11.5 7.8 11.5 7.8 11.5 7.8 11.5 7.8 11.5 7.8 11.5 7.8 11.5 7.8 11.5 7.8 11.5 7.8 11.3 7.6 11.1 7.3 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.1 9.3 13.8 8.9 9-7 -7 22.0°CWB 30°CDB TC SHC 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.0 7.6 11.7 7.3 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.0 9.2 14.6 8.9 24.0°CWB 32°CDB TC SHC 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.5 7.4 12.3 7.1 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 15.6 9.0 15.3 8.6 Heating capacity Unit size 018 024 027 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 5.0 5.3 5.7 5.8 6.2 6.5 6.8 7.1 7.4 7.7 8.0 8.3 8.3 8.3 8.3 8.3 5.6 6.0 6.4 6.6 7.0 7.3 7.7 8.0 8.4 8.7 9.0 9.4 9.4 9.4 9.4 9.4 SHC : Sensible Heat Capacity (kW) Indoor air temp. °CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 3.9 3.8 3.7 3.6 4.1 4.0 3.9 3.8 4.4 4.3 4.2 4.1 4.5 4.4 4.3 4.2 4.8 4.7 4.6 4.4 5.0 4.9 4.8 4.7 5.3 5.2 5.0 4.9 5.5 5.4 5.3 5.1 5.8 5.6 5.5 5.3 6.0 5.9 5.7 5.6 6.2 6.1 5.9 5.8 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 4.9 4.8 4.7 4.6 5.2 5.1 5.0 4.9 5.6 5.5 5.3 5.2 5.7 5.6 5.5 5.3 6.1 5.9 5.8 5.6 6.4 6.2 6.1 5.9 6.7 6.6 6.4 6.2 7.0 6.9 6.7 6.5 7.3 7.1 7.0 6.8 7.6 7.4 7.3 7.1 7.9 7.7 7.5 7.3 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 5.5 5.4 5.3 5.1 5.9 5.8 5.6 5.5 6.3 6.1 6.0 5.8 6.5 6.3 6.2 6.0 6.8 6.7 6.5 6.3 7.2 7.0 6.9 6.7 7.5 7.4 7.2 7.0 7.9 7.7 7.5 7.3 8.2 8.0 7.8 7.6 8.5 8.4 8.2 7.9 8.9 8.7 8.5 8.3 9.2 9.0 8.8 8.6 9.2 9.0 8.8 8.6 9.2 9.0 8.8 8.6 9.2 9.0 8.8 8.6 9.2 9.0 8.8 8.6 9-7 -8 Heating capacity (cont.) Unit size 036 048 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 7.8 8.3 8.9 9.1 9.7 10.2 10.7 11.1 11.6 12.1 12.6 13.0 13.0 13.0 13.0 13.0 10.0 10.7 11.4 11.7 12.4 13.0 13.6 14.3 14.9 15.5 16.1 16.7 16.7 16.7 16.7 16.7 Indoor air temp. °CDB 18.0 20.0 22.0 SHC SHC SHC 7.7 7.5 7.3 8.2 8.0 7.8 8.7 8.5 8.3 9.0 8.8 8.6 9.5 9.3 9.1 10.0 9.8 9.5 10.5 10.2 10.0 10.9 10.7 10.5 11.4 11.2 10.9 11.9 11.6 11.3 12.3 12.1 11.8 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 9.8 9.6 9.4 10.5 10.3 10.0 11.1 10.9 10.7 11.5 11.2 11.0 12.1 11.9 11.6 12.8 12.5 12.2 13.4 13.1 12.8 14.0 13.7 13.4 14.6 14.3 14.0 15.2 14.9 14.5 15.8 15.4 15.1 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 24.0 SHC 7.2 7.6 8.1 8.3 8.8 9.3 9.7 10.2 10.6 11.0 11.5 11.9 11.9 11.9 11.9 11.9 9.1 9.7 10.4 10.7 11.3 11.9 12.4 13.0 13.6 14.1 14.7 15.2 15.2 15.2 15.2 15.2 9-7 -9 9-7-5. Fan characteristics MMD-AP0241H, AP0271H Standard air volume: 900 m3/h 1.5 Fan motor current (A) Fan motor current (A) MMD-AP0181H High static pressure tap Medium static pressure tap 1.0 0.5 Low static pressure tap Standard air volume: 1,320 m3/h 2.0 High static pressure tap Medium static pressure tap 1.5 Low static pressure tap 1.0 300 250 st at ic pr es su re ta p at ic pr es s M ed ur iu m st at ic e ta p pr es su 100 re ta p re su es pr ta 50 50 700 800 900 1,000 p 0 150 st ic ta p 200 at pr es su re tap Air volume upper limit Lo w st at ic ure Hi gh st 100 ss M ed iu m Air volume lower limit 150 pre Air volume upper limit tic Outside static pressure (Pa) sta 200 50Hz 60Hz w Lo Outside static pressure (Pa) gh 250 Air volume lower limit 50Hz 60Hz Hi 0 1,000 1,100 1,100 1,200 1,320 1,300 1,400 1,500 1,600 Air volume (m³/h) Air volume (m³/h) MMD-AP0361H MMD-AP0481H Standard air volume: 2,100 m3/h 3 Standard air volume: 1,600 m /h 3.0 Fan motor current (A) Fan motor current (A) 2.5 High static pressure tap 2.0 Medium static pressure tap 1.5 Low static pressure tap High static pressure tap 2.5 2.0 Medium static pressure tap 1.5 1.0 Low static pressure tap 150 100 Me diu m sta tic pre ssu re t pre ssu re Lo ws tat tap ic p res su re 50 0 ap 250 200 150 100 tap 50 1,400 1,500 1,600 1,700 0 1,800 50Hz Hig hs 60Hz tat ic pre ss ure M tap ed ium sta tic pr es su re Lo ta p w st at ic pr es su re ta p 2,100 1,500 2,000 Air volume (m³/h) Air volume (m³/h) 9-7 -10 Air volume upper limit atic 200 Air volume lower limit Outside static pressure (Pa) h st Air volume lower limit 50Hz 60Hz Hig Outside static pressure (Pa) 250 Air volume upper limit 0.5 2,500 9-7-6. Sound characteristics (NC-Curve) Sound level values shown are based on a measurement in a non resound room. Microphone (dB) (dB) Outside still pressure 68.6 (Pa) 137.2 (Pa) 196.0 (Pa) Outside still pressure 68.6 (Pa) 137.2 (Pa) 196.0 (Pa) Overall level A (dB) C 33 37 40 46 51 53 Overall level A Octave band sound pressure level (dB) Octave band sound pressure level (dB) MMD-AP0181H (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continuous white level (dB) 37 40 47 49 53 196.0(external static pressure(Pa)) Audibility limits of continuous white level Octave band center frequency (Hz) (dB) (dB) Outside still pressure 68.6 (Pa) 137.2 (Pa) 196.0 (Pa) Outside still pressure 68.6 (Pa) 137.2 (Pa) 196.0 (Pa) Overall level A (dB) C 36 40 44 50 53 57 (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continuous white level Octave band center frequency (Hz) Octave band sound pressure level (dB) Octave band sound pressure level (dB) 33 (standard sound pressure 0.0002 µbar) Octave band center frequency (Hz) MMD-AP0241H, AP0271H C Overall level A (dB) C 36 40 44 50.5 53 57 (standard sound pressure 0.0002 µbar) 9-7 -11 196.0(external static pressure(Pa)) Audibility limits of continuous white level Octave band center frequency (Hz) MMD-AP0361H (dB) (dB) Octave band sound pressure level (dB) Overall level A (dB) C 68.6 (Pa) 137.2 (Pa) 196.0 (Pa) 36 40 44 49.5 54 59 Octave band sound pressure level (dB) Outside still pressure (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continuous white level Octave band center frequency (Hz) Outside still pressure 68.6 (Pa) Overall level A 36 40 44 49 53.5 57 (dB) C 137.2 (Pa) 196.0 (Pa) (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continuous white level Octave band center frequency (Hz) (dB) 68.6 (Pa) Overall level A 36 40 44 47 51 54 (dB) C 137.2 (Pa) 196.0 (Pa) (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continuous white level Octave band center frequency (Hz) Octave band sound pressure level (dB) Octave band sound pressure level (dB) (dB) Outside still pressure 9-7 -12 Outside still pressure 68.6 (Pa) Overall level A 36 40 44 47 51 54 (dB) C 137.2 (Pa) 196.0 (Pa) (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continuous white level Octave band center frequency (Hz) Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. MMD-AP0721H (50Hz) Overall level A Octave band sound pressure level (dB) (dB) C 69 (Pa) 137 (Pa) 196 (Pa) 48 49 50.5 54 55 57 (60Hz) Outside still pressure Overall level A (dB) Octave band sound pressure level (dB) Outside still pressure Audibility limits of continuous white level C 69 (Pa) 137 (Pa) 196 (Pa) 48 49 50.5 55 50 58 Audibility limits of continuous white level Octave band center frequency (Hz) Octave band center frequency (Hz) MMD-AP0961H (50Hz) Overall level A Octave band sound pressure level (dB) (dB) C 69 (Pa) 137 (Pa) 196 (Pa) 49 50 51.5 56 59 61 Audibility limits of continuous white level (60Hz) Outside still pressure Overall level A (dB) Octave band sound pressure level (dB) Outside still pressure Octave band center frequency (Hz) C 69 (Pa) 137 (Pa) 196 (Pa) 49 50 51.5 57 59 61 Audibility limits of continuous white level Octave band center frequency (Hz) 9-7 -13 9-7-7. Accessories Apperarance Standard accessories Part name Qty Installation Manual 1 Insulation 1 Shape Use Part name Qty Insulation 1 For insulating the gas pipe connection Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-7 -14 Shape Use For insulating the liquid pipe connection Optional accessories Filter Chamber TCB-FCY21DE, TCB-FCY31DE TCB-FCY51DE Long Life Pre-Filter TCB-PF1D-1E TCB-PF2D-1E High Efficiency Filter 65 TCB-UFM1D-1E, TCB-UFM2D-1E Drain pump kit TCB-DP31DE Name High Efficiency Filter 65 High Efficiency Filter 90 Long life Pre-filter High Efficiency Filter 90 TCB-UFH5D-1E, TCB-UFH6D-1E Model name TCB-UFM1D-1E Dust collecting effect :65% (NBS Colorimentric method) Use with TCB-FCY21D TCB-UFM2D-1E(2 pcs.) Dust collecting effect :65% (NBS Colorimentric method) Use with TCB-FCY31D TCB-UFM1D-1E(2 pcs.) Dust collecting effect :65% (NBS Colorimentric method) Use with TCB-FCY41D TCB-UFH5D-1E Dust collecting effect :90% (NBS Colorimentric method) Use with TCB-FCY21D TCB-UFH6D-1E (2 pcs.) Dust collecting effect :90% (NBS Colorimentric method) Use with TCB-FCY31D TCB-UFH5D-1E (2 pcs.) Dust collecting effect :90% (NBS Colorimentric method) Use with TCB-FCY41D TCB-PF1D-1E Dust collecting effect :50% (Weight method) Use with TCB-FCY21D TCB-PF2D-1E (2 pcs.) Dust collecting effect :50% (Weight method) Use with TCB-FCY31D TCB-PF1D-1E (2 pcs.) Dust collecting effect :50% (Weight method) Use with TCB-FCY41D TCB-FCY21DE Filter Chamber Note TCB-FCY31DE For high efficiency filter or long life pre-filter TCB-FCY51DE Drain Pump Kit TCB-DP31DE Stand-up 330 or less (from bottom face of ceiling) 9-7 -15 9-8-1. Specifications 50Hz Specifications (50Hz) Model name MMC- AP0151H AP0181H AP0241H AP0271H AP0361H AP0481H (kW) 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 Cooling/Heating capacity (Note 1) 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) Power supply Electrical characteristics Running current (A) Power consumption (kW) Appearance Starting current Outer dimension 0.29 0.32 0.42 0.78 0.84 0.033 0.038 0.050 0.091 0.110 0.43 0.48 0.62 1.17 1.25 (A) Height x Width x Depth Total weight White (Munsell 10Y 9.3/0.4) (mm) 210 x 910 x 680 210 x 1,180 x 680 210 x 1,595 x 680 (kg) 22 26 34 Finned tube Heat exchanger Non-flammable insulation Soundproof/Heat-insulating material Centrifugal fan Fan Fan unit Standard air flow (High/Mid/Low) Motor (m3/h) 780/660/540 720/600/540 30 (W) 1,800/1,560/ 1,320 1,650/1,380/ 1,200 1,110/900/840 40 80 Remote controller Controller Standard filter (Long life filter) Air filter Gas side Connecting Liquid side pipe Drain port (mm) O / 12.7 O / 15.9 (mm) O / 6.4 O / 9.5 20 (Polyvinyl chloride tube) (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) 35/32/30 36/33/30 PMV Kit 38/36/33 41/38/35 43/40/37 Not available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-8 -1 60Hz Specifications (60Hz) Model name Cooling/Heating capacity (Note 1) MMC- AP0151H AP0181H AP0241H AP0271H AP0361H AP0481H (kW) 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Power supply Running current Electrical characteristics (A) 0.30 0.34 0.44 0.82 0.87 Power consumption (kW) 0.033 0.038 0.050 0.091 0.110 Starting current 0.43 0.48 0.62 1.17 1.25 (A) White (Munsell 10Y 9.3/0.4) Appearance Outer Height x Width x Depth dimension Total weight (mm) 210 x 910 x 680 210 x 1,180 x 680 210 x 1,595 x 680 (kg) 22 26 34 Finned tube Heat exchanger Soundproof/Heat-insulating material Non-flammable insulation Fan Centrifugal fan Fan unit Standard air flow (High/Mid/Low) Motor (m3/h) 720/600/540 (W) 780/660/540 30 1,650/1,380/1,200 1,800/1,560/1,320 40 80 Remote controller Controller Air filter Connecting pipe 1,110/900/840 Standard filter (Long life filter) Gas side (mm) O / 12.7 O / 15.9 Liquid side (mm) O / 6.4 O / 9.5 Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (db(A)) 20 (Polyvinyl chloride tube) 35/32/30 36/33/30 38/36/33 41/38/35 43/40/37 Not available PMV Kit Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 9-8 -2 O O O 9-8-2. Dimension MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H Upper piping drawing-out port (Knockout hole) Piping drawing-out port (Knockout port) 70 (Hanging position) Drain port VP20 (Inner diam. O / 26, hose supplied) Left drain size Drain pipe connecting port B (Hanging position) Refrigerant pipe (Liquid side O / D) Refrigerant pipe (Gas side O / C) Model MMC- A A B C D AP0151H, AP0181H 910 855 12.7 6.4 AP0241H, AP0271H 1180 1125 15.9 9.5 AP0361H, AP0481H 1595 1540 15.9 9.5 Wireless sensor mounting section (Optional) Ceiling surface Unit 250 or more 250 or more (Front side to be positioned horizontally.) 500 or more Within 50 Hanging bolt Space required for installation and servicing Remote controller cable taking-in port Power supply taking-in port (Knockout hole) Remote controller cable taking-in port (Knockout hole) 2.7 4 Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 120 320 170 Power supply cable taking-in port (Knockout) Remote controller piping taking-in port (Knockout hole) Wireless remote controller kit TCB-AX22CE2 120 16 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Air taking-in port (Duct sold separately) (Knockout hole O / 92) Drain left piping drawing-out port Piping hole on the wall (Knockout hole) (O / 100 hole) Note: All dimensions are in mm. 9-8 -3 RED Flow selector unit earth screw DM 9-8 -4 3 CN304 1 (GRY) 2 1 1 2 2 3 3 CN68 (BLU) CN41 (BLU) CN40 (BLU) CN66 (WHI) Fuse T6.3A 250V~ P301 RY303 RY302 BLK Ð Adpter for wireless remote controller CN001 (WHI) BLK WHI BLK 3 3 2 2 1 1 Option 1 2 3 4 5 6 CN60 (WHI) DC20V DC15V DC12V DC7V indicates the terminal number. indicates the terminal block, the letter inside X Y 1 2 CN03 1 2 (RED) Network adaptor P.C. board Network CN01 1 2 adaptor (WHI) 1 2 (Option) CN02 (BLU) TR 1 2 Fandrive T10 CN32 (WHI) Power supply circuit 3. indicates the control P.C. board. CN81 (BLK) Sold separately 1 2 3 4 5 2 . A dotted line and broken line indicate the wiring on site. 1. 1 2 3 4 5 CN61 (YEL) Fuse T3.15A Indoor control P.C. board CN70 (WHI) CN73 (RED) CN80 (GRN) CN100 (BRW) TA 1 FILTER 2 RED WHI YEL BLU BRN BLK GRY PNK ORN GRN : BLACK : GRAY : PINK : ORANGE : GREEN Parts name Fan motor Indoor temp sensor Temp sensor Louver motor Drain control relay Drain pump motor Float switch : RED : WHITE : YELLOW : BLUE : BROWN TC1 TC2 TCJ 1 EXCT 2 1 2 PNL 3 1 1 2 2 3 3 1 1 2 2 1 1 2 2 CN102 (RED) CN101 (BLK) 1 1 2 2 CN104 (YEL) Color identification GRL FS 1 3 CN34 1 2 3 (RED) 1 2 3 4 5 CN20 (BLU) Symbol FM TA TC1,TC2,TCJ LM RY302 DM FS 1 2 3 4 5 CN33 1 2 3 4 5 (WHI) 1 2 3 4 5 6 CN82 1 2 3 4 5 6 (BLU) LM 1 2 3 4 5 1 2 3 4 5 6 4 3 1 2 5 6 4 3 1 2 5 1 2 3 4 5 6 Motor drive circuit + CN50 (WHI) Wired remote controller WHI 1 2 3 1 2 3 CN309 (YEL) ~ ~ 1 2 1 2 CN1 (WHI) FM 5 4 1 CN334 1 2 3 4 5 CN333 5 4 3 2 1 (WHI) 1 2 3 4 5 (WHI) 1 2 1 2 WHI U1 U2 A B 1 1 2 BLK 3 3 BLK 2 2 BLU 1 1 BLU 1 2 BLK 1 1 CN67 (BLK) 2 2 3 3 Outdoor unit U1 U2 Closed end terminal RED WHI Power supply single phase 200-240V 50Hz 200V 60Hz R(L) S(N) Earth screw Indoor unit WHI PMV 9-8-3. Wiring diagram Model: MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H 9-8-4. Sensible capacity table (MMD-AP***H) Cooling capacity Unit size 015 018 024 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.0 3.0 3.9 2.8 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.0 3.6 4.9 3.5 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.3 4.7 6.2 4.5 18.0°CWB 26°CDB TC SHC 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.4 3.2 4.3 3.1 4.2 3.0 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.4 3.9 5.3 3.8 5.2 3.7 6.9 5.1 6.9 5.1 6.9 5.1 6.9 5.1 6.9 5.1 6.9 5.1 6.9 5.1 6.9 5.1 6.9 5.1 6.9 5.1 6.9 5.1 6.9 5.1 6.9 5.1 6.9 5.1 6.7 5.0 6.6 4.8 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0°CWB 20.0°CWB 22.0°CWB 24.0°CWB 27°CDB 28°CDB 30°CDB 32°CDB TC SHC TC SHC TC SHC TC SHC 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.5 3.2 4.6 3.2 4.9 3.2 5.1 3.1 4.4 3.1 4.5 3.1 4.8 3.1 5.0 3.0 4.3 3.0 4.4 3.0 4.7 3.0 4.9 2.9 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.6 3.9 5.8 3.9 6.1 3.9 6.4 3.8 5.5 3.8 5.7 3.8 6.0 3.8 6.3 3.7 5.4 3.7 5.5 3.7 5.9 3.6 6.1 3.6 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.1 5.1 7.3 5.1 7.7 5.1 8.1 4.9 7.0 5.0 7.2 5.0 7.6 5.0 7.9 4.8 6.8 4.8 7.0 4.8 7.4 4.8 7.8 4.6 9-8 -5 Cooling capacity (cont.) Unit size 027 036 048 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.1 5.2 7.0 5.0 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.0 7.0 9.8 6.8 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.5 9.1 12.2 8.7 18.0°CWB 26°CDB TC SHC 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.8 5.6 7.6 5.5 7.4 5.3 10.9 7.6 10.9 7.6 10.9 7.6 10.9 7.6 10.9 7.6 10.9 7.6 10.9 7.6 10.9 7.6 10.9 7.6 10.9 7.6 10.9 7.6 10.9 7.6 10.9 7.6 10.9 7.6 10.6 7.5 10.4 7.2 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.6 9.8 13.3 9.6 13.0 9.2 Indoor air temp. 19.0°CWB 27°CDB TC SHC 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 8.0 5.6 7.8 5.5 7.7 5.3 11.2 7.6 11.2 7.6 11.2 7.6 11.2 7.6 11.2 7.6 11.2 7.6 11.2 7.6 11.2 7.6 11.2 7.6 11.2 7.6 11.2 7.6 11.2 7.6 11.2 7.6 11.2 7.6 11.0 7.4 10.8 7.2 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 14.0 9.8 13.7 9.6 13.4 9.2 20.0°CWB 28°CDB TC SHC 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.2 5.6 8.1 5.5 7.9 5.3 11.5 7.6 11.5 7.6 11.5 7.6 11.5 7.6 11.5 7.6 11.5 7.6 11.5 7.6 11.5 7.6 11.5 7.6 11.5 7.6 11.5 7.6 11.5 7.6 11.5 7.6 11.5 7.6 11.3 7.4 11.1 7.1 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.4 9.8 14.1 9.6 13.8 9.2 9-8 -6 22.0°CWB 30°CDB TC SHC 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.5 5.4 8.4 5.2 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.0 7.4 11.7 7.1 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.0 9.5 14.6 9.1 24.0°CWB 32°CDB TC SHC 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 8.9 5.3 8.8 5.1 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.5 7.2 12.3 6.9 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 15.6 9.3 15.3 8.9 Heating capacity Unit size 015 018 024 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.1 3.3 3.6 3.7 3.9 4.1 4.3 4.5 4.7 4.8 5.0 5.2 5.2 5.2 5.2 5.2 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 5.0 5.3 5.7 5.8 6.2 6.5 6.8 7.1 7.4 7.7 8.0 8.3 8.3 8.3 8.3 8.3 SHC : Sensible Heat Capacity (kW) Indoor air temp. °CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 3.1 3.0 2.9 2.9 3.3 3.2 3.1 3.0 3.5 3.4 3.3 3.2 3.6 3.5 3.4 3.3 3.8 3.7 3.6 3.5 4.0 3.9 3.8 3.7 4.2 4.1 4.0 3.9 4.4 4.3 4.2 4.1 4.6 4.5 4.4 4.2 4.7 4.6 4.5 4.4 4.9 4.8 4.7 4.6 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 3.9 3.8 3.7 3.6 4.1 4.0 3.9 3.8 4.4 4.3 4.2 4.1 4.5 4.4 4.3 4.2 4.8 4.7 4.6 4.4 5.0 4.9 4.8 4.7 5.3 5.2 5.0 4.9 5.5 5.4 5.3 5.1 5.8 5.6 5.5 5.3 6.0 5.9 5.7 5.6 6.2 6.1 5.9 5.8 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 4.9 4.8 4.7 4.6 5.2 5.1 5.0 4.9 5.6 5.5 5.3 5.2 5.7 5.6 5.5 5.3 6.1 5.9 5.8 5.6 6.4 6.2 6.1 5.9 6.7 6.6 6.4 6.2 7.0 6.9 6.7 6.5 7.3 7.1 7.0 6.8 7.6 7.4 7.3 7.1 7.9 7.7 7.5 7.3 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 9-8 -7 Heating capacity (cont.) Unit size 027 036 048 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 5.6 6.0 6.4 6.6 7.0 7.3 7.7 8.0 8.4 8.7 9.0 9.4 9.4 9.4 9.4 9.4 7.8 8.3 8.9 9.1 9.7 10.2 10.7 11.1 11.6 12.1 12.6 13.0 13.0 13.0 13.0 13.0 10.0 10.7 11.4 11.7 12.4 13.0 13.6 14.3 14.9 15.5 16.1 16.7 16.7 16.7 16.7 16.7 Indoor air temp. °CDB 18.0 20.0 22.0 SHC SHC SHC 5.5 5.4 5.3 5.9 5.8 5.6 6.3 6.1 6.0 6.5 6.3 6.2 6.8 6.7 6.5 7.2 7.0 6.9 7.5 7.4 7.2 7.9 7.7 7.5 8.2 8.0 7.8 8.5 8.4 8.2 8.9 8.7 8.5 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 7.7 7.5 7.3 8.2 8.0 7.8 8.7 8.5 8.3 9.0 8.8 8.6 9.5 9.3 9.1 10.0 9.8 9.5 10.5 10.2 10.0 10.9 10.7 10.5 11.4 11.2 10.9 11.9 11.6 11.3 12.3 12.1 11.8 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 9.8 9.6 9.4 10.5 10.3 10.0 11.1 10.9 10.7 11.5 11.2 11.0 12.1 11.9 11.6 12.8 12.5 12.2 13.4 13.1 12.8 14.0 13.7 13.4 14.6 14.3 14.0 15.2 14.9 14.5 15.8 15.4 15.1 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 24.0 SHC 5.1 5.5 5.8 6.0 6.3 6.7 7.0 7.3 7.6 7.9 8.3 8.6 8.6 8.6 8.6 8.6 7.2 7.6 8.1 8.3 8.8 9.3 9.7 10.2 10.6 11.0 11.5 11.9 11.9 11.9 11.9 11.9 9.1 9.7 10.4 10.7 11.3 11.9 12.4 13.0 13.6 14.1 14.7 15.2 15.2 15.2 15.2 15.2 9-8 -8 9-8-5. Air throw distance chart MMC-AP0181H,AP0481H 1m MMC-AP0361H 1m 2m 2m 1.0 3m 0.3 1m 3m 4m 1m 1m 2m 1.0 0.3 0.3 1m 2m 0.3 0.5 MMC-AP015H,AP0241H,AP0271H 3m 0.3 0.5 3m 0.5 2m 1.0 0.3 0.5 3m 4m 9-8 -9 2m 3m 4m 9-8-6. Sound characteristics (NC-Curve) Sound level values shown are based on a measurement in a non resound room. MMC-AP0151H H M L 35 32 30 Octave band sound pressure level (dB) Fan Tap Sound pressure level (dB(A)) Microphone 90 H M L 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continuous white level 10 NC-20 ~ 75 ~ 150 ~ 300 ~ 600 ~ 1200 ~ 2400 ~ 4800 75 150 300 600 1200 2400 4800 9600 ~ 20 Octave band frequency (Hz) MMC-AP0181H MMC-AP0241H,AP0271H H M L Fan Tap H M L Sound pressure level (dB(A)) 36 33 30 Sound pressure level (dB(A)) 38 36 33 Octave band sound pressure level (dB) 90 H M L 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 NC-20 Audibility limits of continuous white level 10 Octave band sound pressure level (dB) Fan Tap 90 H M L 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continuous white level 10 NC-20 ~ 75 ~ 150 ~ 300 ~ 600 ~ 1200 ~ 2400 ~ 4800 ~ 20 ~ 75 ~ 150 ~ 300 ~ 600 ~ 1200 ~ 2400 ~ 4800 75 150 300 600 1200 2400 4800 9600 75 150 300 600 1200 2400 4800 9600 Octave band frequency (Hz) Octave band frequency (Hz) MMC-AP0361H MMC-AP0481H Fan Tap H M L Fan Tap H M L Sound pressure level (dB(A)) 41 38 35 Sound pressure level (dB(A)) 43 40 37 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 NC-20 Audibility limits of continuous white level 10 NC-40 30 NC-30 20 NC-20 Audibility limits of continuous white level 10 75 150 300 600 1200 2400 4800 9600 75 150 300 600 1200 2400 4800 9600 Octave band frequency (Hz) Octave band frequency (Hz) 9-8 -10 ~ 20 ~ ~ 4800 4800 40 ~ ~ 2400 2400 NC-50 ~ ~ 1200 1200 NC-60 50 ~ ~ 600 600 60 ~ ~ 300 300 NC-70 ~ ~ 150 150 70 ~ 75 75 H M L 80 ~ 20 Octave band sound pressure level (dB) 90 H M L ~ Octave band sound pressure level (dB) ~ 20 9-8-7. Accessories Apperarance Standard accessories Part name Qty Shape Use Part name Qty Shape Use Installation Manual 1 (Be sure to hand over to the customer) Heat insulator 1 For heat insulation of drain connecting section Heat insulating pipe 2 For heat insulation of pipe connecting section Washer 4 For hanging-down unit Installation pattern 1 For confirmation of ceiling opening and main unit position Hose band 2 For connecting drain pipe Banding band 2 For drain hose forming Drain hose 1 For drain piping Bushing 1 For power supply cord protection Heat insulator 1 For sealing of piping hole Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-8 -11 Optional accessories Elbow piping kit TCB-KP12CE2 TCB-KP22CE2 Drain pump kit TCB-DP22CE2 Name Drain Pump Kit Elbow Piping Kit Model name TCB-DP22CE TCB-KP12CE Note Stand-up 600 or less (from bottom face of ceiling) MMC-AP0151/0181H Type (Use with TCB-KP12CE) MMC-AP0241H/0271/0361H/0481H (Use with TCB-KP22CE) Needed when Drain Pump Kid is used TCB-KP22CE 9-8 -12 9-9-1. Specifications 50Hz Specifications (50Hz) Model name MMK- AP0071H AP0091H AP0121H AP0151H AP0181H AP0241H (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 Cooling/Heating capacity (Note 1) 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) Power supply Electrical characteristics Running current Power consumption (A) 0.30 0.32 0.35 (kW) 0.035 0.037 0.040 (A) 0.36 0.42 0.47 Starting current Suction grille and side panel Appearance Outer dimension Silky mist (Munsell 1Y 8.9/0.5) Discharge grille City gray (Munsell N6.5) Bottom surface Silky mist (Munsell 1Y 8.9/0.5) Height x Width x Depth Total weight (mm) 368 x 895 x 210 368 x 1,055 x 210 368 x 1,430 x 210 (kg) 18 19 25 780/660/600 1,200/1,020/900 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Cross-flow fan Fan Fan unit Standard air flow (High/Mid/Low) Motor outlet (m3/h) 600/540/480 30 (W) Standard filter (Simple filter) Air filter Remote controller Controller Gas side Connecting Liquid side pipe (mm) O / 9.5 O / 6.4 (mm) (dB(A)) O / 15.9 O / 9.5 20 (Polyvinyl chloride tube) Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) O / 12.7 39/34/31 PMV Kit 42/38/35 42/38/35 Available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-9 -1 60Hz Specifications (60Hz) Model name Cooling/Heating capacity (Note 1) MMK- AP0071H AP0091H AP0121H AP0151H AP0181H AP0241H (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Power supply Running current Electrical characteristics Power consumption (A) 0.32 0.34 0.35 (kW) 0.035 0.037 0.040 (A) 0.46 0.48 0.60 Starting current Silky mist (Munsell 1Y 8.9/0.5) Suction grille and side panel Appearance Outer dimension Discharge grille City gray (Munsell N6.5) Bottom surface Silky mist (Munsell 1Y 8.9/0.5) Height x Width x Depth Total weight (mm) 368 x 895 x 210 368 x 1,055 x 210 368 x 1,430 x 210 (kg) 18 19 25 780/660/600 1,200/1,020/900 Finned tube Heat exchanger Non-flammable insulation Soundproof/Heat-insulating material Cross-flow fan Fan Fan Standard air flow (High/Mid/Low) unit (m3/h) 600/540/480 (W) Motor outlet 30 Air filter Standard filter (Simple filter) Controller Connecting pipe Remote controller Gas side (mm) Liquid side (mm) O / 9.5 O / 12.7 O / 6.4 Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) O / 15.9 O / 9.5 20 (Polyvinyl chloride tube) 39/34/31 42/38/35 PMV Kit 42/38/35 Available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 9-9 -2 O O O 9-9-2. Dimension MMK-AP0071H, AP0091H, AP0121H Position of holes on the installation plate. Long hole for wooden screw 15-6 X 30 690 (Installation plate) Hole for anchor bolt 10-10 X 20 long hole (Including installation plate) 210 Including installation plate (Accessory) Earth screw (M4) (Inside of electric parts box) Upper end of installation plate Refrigerant pipe connecting port O Gas side 9.5 / 9.5 Refrigerant pipe connecting port Liquid side O / 6.4 Drain pipe connecting port Air suction port Discharge port (Air direction upward/downward/leftward/rightward are adjustable.) Piping port from left/right sides (Knockout hole) 30 or more Gas pipe 440 Liquid pipe 540 Drain pipe 560 At shipment (When drawing pipe from left) 300 or more 300 or more Space required for service 2.7 Wired remote controller RBC-AMT31E 4 remote controller Simple wired RBC-AS21E2 120 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 120 16 Note: All dimensions are in mm. 9-9 -3 MMK-AP0151H, AP0181H 182.5 Hole for wooden screw 15-6 X 30 182.5 690 (Installation plate) Hole for anchor bolt 10-10 X 20 long hole (Including installation plate) 210 Including installation plate (Accessory) Earth screw (M4) (Inside of electric parts box) Refrigerant pipe Refrigerant pipe connecting port connecting port Liquid side O / 6.4 Gas side O/ 12.7 Upper end of installation plate Air suction port Air discharge port (Air direction upward/downward/leftward/rightward air adjustable.) Drain pipe connecting port Piping port from left/right sides (Knockout hole) 30 or more Gas pipe 440 Liquid pipe 540 Drain pipe 560 At shipment (When drawing pipe from left) 300 or more Wired remote controller RBC-AMT31E 300 or more Space required for service Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Note: All dimensions are in mm. 9-9 -4 MMK-AP0241H Position of holes on the installation plate Hole for wooden screw 21-6 X 30 170 1090 (Installation plate) Hole for anchor bolt 16-10 X 20 long hole 170 (Including installation plate) 210 Including installation plate (Accessory) Earth screw (M4) (Inside of electric parts box) Upper end of installation plate Refrigerant pipe connecting port Gas side O / 15.9 Air discharge port (Air direction upward/ Air suction port downward/leftward/rightward air adjustable.) Refrigerant pipe connecting port Liquid side O / 9.5 Drain pipe connecting port Piping port from left/right sides (Knockout hole) 30 or more Gas pipe 440 Liquid pipe 540 Drain pipe 560 At shipment (When drawing pipe from left) 300 or more 300 or more Space required for service Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Note: All dimensions are in mm. 9-9 -5 9-9 -6 RED : RED WHI : WHITE YEL :YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication Earth screw Indoor unit Power supply single phase 220-240V 50Hz 220V 60Hz R(L) S(N) Outdoor unit X GRY 1 2 1 2 CN001 (WHI) BLK Wired remote Adapter for controller wireless remote controller 1 2 1 2 CN1 (WHI) Y GRY BLK BLK BLK WHI 1 2 3 1 3 1 2 1 2 BLU BLU CN41 (BLU) CN40 (BLU) CN50 (WHI) 1 2 1 2 CN03(RED) CN01(WHI) CN02 (BLU) 1 2 1 2 1 2 3 4 5 6 Network Adapter (Option) MCC-1401 3 3 2 1 1 TR 1 2 3 4 5 CN61 (YEL) 3 3 1 1 2 2 TC2 Option 1 2 3 4 5 CN81 (BLK) 1 2 3 4 5 CN20 (BLU) CN70 (WHI) CN73 (RED) CN080 (GRN) CN100 (BRW) CN103 (GRN) 1 3 1 2 3 TC1 1 2 1 2 EXCT 1 2 3 1 2 3. Symbol FM TA TC1,TC2,TCJ PMV LM RY303 Parts name Fan motor Indoor temp sensor Temp sensor Pulse motor valve Lover motor Louver control relay indicates the control P.C. board. 2 . A dotted line and broken line indicate the wiring on site. indicates the terminal number. indicates the terminal block, the letter inside 1 2 3 4 5 6 1. 1 1 2 2 TCJ CN104 CN102 CN101 (YEL) (RED) (BLK) 1 1 2 2 TA Control P.C. board for Indoor unit MCC-1402 1 2 CN60 (WHI) DC20V DC15V DC12V DC7V CN34 (RED) 1 1 Fandrive CN32 (WHI) Power supply circuit CN33 (WHI) CN82 (BLU) FUSE 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 6 T3.15A 250V~ 3 CN309 3 (YEL) 5 5 6 4 3 1 2 5 6 4 3 1 2 5 PMV FUSE 1 1 3 3 Motor drive circuit CN333 1 (WHI) 1 1 2 3 1 2 3 FM T6.3A 250V~ RY303 RY302 BLK WHI B CN66 (WHI) 1 2 P301 BLK 3 3 CN67 (BLK) 1 1 3 3 CN304 (GRY) A WHI U1 U2 U1 U2 RED Closed-end connector WHI Flow selector unit earth screw WHI RED LM 3 1 1 1 CN68 (BLU) CN334 5 4 2 1 (WHI) 5 4 3 2 1 1 1 5 5 4 4 9-9-3. Wiring diagram Model: MMK-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H 9-9-4. Sensible capacity table (MMD-AP***H) Cooling capacity Unit size 007 009 012 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 1.9 1.5 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.4 1.8 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.2 2.3 3.1 2.2 18.0°CWB 26°CDB TC SHC 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.0 1.6 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.6 1.9 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.4 2.5 3.4 2.4 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0°CWB 20.0°CWB 22.0°CWB 24.0°CWB 27°CDB 28°CDB 30°CDB 32°CDB TC SHC TC SHC TC SHC TC SHC 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.2 1.7 2.4 1.7 2.5 1.6 2.1 1.6 2.2 1.6 2.3 1.6 2.4 1.5 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 3.0 1.9 3.1 1.9 2.7 1.9 2.8 1.9 2.9 1.9 3.1 1.8 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.4 3.8 2.4 4.0 2.4 3.5 2.4 3.6 2.4 3.8 2.3 3.9 2.3 9-9 -7 Cooling capacity (cont.) Unit size 015 018 024 Outdoor air temp. °CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0°CWB 23°CDB TC SHC 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.0 2.7 3.9 2.6 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.0 3.3 4.9 3.2 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.3 4.3 6.2 4.2 18.0°CWB 26°CDB TC SHC 4.4 2.9 4.4 2.9 4.4 2.9 4.4 2.9 4.4 2.9 4.4 2.9 4.4 2.9 4.4 2.9 4.4 2.9 4.4 2.9 4.4 2.9 4.4 2.9 4.4 2.9 4.4 2.9 4.3 2.9 4.2 2.7 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.4 3.6 5.3 3.5 5.2 3.4 6.9 4.7 6.9 4.7 6.9 4.7 6.9 4.7 6.9 4.7 6.9 4.7 6.9 4.7 6.9 4.7 6.9 4.7 6.9 4.7 6.9 4.7 6.9 4.7 6.9 4.7 6.9 4.7 6.7 4.6 6.6 4.4 Indoor air temp. 19.0°CWB 27°CDB TC SHC 4.5 2.9 4.5 2.9 4.5 2.9 4.5 2.9 4.5 2.9 4.5 2.9 4.5 2.9 4.5 2.9 4.5 2.9 4.5 2.9 4.5 2.9 4.5 2.9 4.5 2.9 4.5 2.9 4.4 2.8 4.3 2.7 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.6 3.6 5.5 3.5 5.4 3.4 7.1 4.7 7.1 4.7 7.1 4.7 7.1 4.7 7.1 4.7 7.1 4.7 7.1 4.7 7.1 4.7 7.1 4.7 7.1 4.7 7.1 4.7 7.1 4.7 7.1 4.7 7.1 4.7 7.0 4.6 6.8 4.4 9-9 -8 20.0°CWB 28°CDB TC SHC 4.6 2.9 4.6 2.9 4.6 2.9 4.6 2.9 4.6 2.9 4.6 2.9 4.6 2.9 4.6 2.9 4.6 2.9 4.6 2.9 4.6 2.9 4.6 2.9 4.6 2.9 4.6 2.9 4.5 2.8 4.4 2.7 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.7 3.5 5.5 3.4 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.2 4.6 7.0 4.4 22.0°CWB 30°CDB TC SHC 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.8 2.8 4.7 2.7 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.0 3.5 5.9 3.4 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.6 4.6 7.4 4.4 24.0°CWB 32°CDB TC SHC 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.0 2.8 4.9 2.6 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.3 3.4 6.1 3.3 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 7.9 4.5 7.8 4.3 Heating capacity Unit size 007 009 012 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.6 2.6 2.6 2.6 2.0 2.1 2.3 2.3 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.3 3.3 3.3 3.3 2.5 2.7 2.8 2.9 3.1 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.2 4.2 4.2 4.2 SHC : Sensible Heat Capacity (kW) Indoor air temp. °CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 1.5 1.5 1.5 1.4 1.6 1.6 1.6 1.5 1.7 1.7 1.7 1.6 1.8 1.8 1.7 1.7 1.9 1.9 1.8 1.8 2.0 2.0 1.9 1.9 2.1 2.0 2.0 1.9 2.2 2.1 2.1 2.0 2.3 2.2 2.2 2.1 2.4 2.3 2.3 2.2 2.5 2.4 2.4 2.3 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.0 1.9 1.9 1.8 2.1 2.1 2.0 1.9 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.1 2.4 2.4 2.3 2.3 2.6 2.5 2.4 2.4 2.7 2.6 2.6 2.5 2.8 2.7 2.7 2.6 2.9 2.9 2.8 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 2.9 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 2.5 2.4 2.3 2.3 2.6 2.6 2.5 2.4 2.8 2.7 2.7 2.6 2.9 2.8 2.7 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 3.0 3.3 3.3 3.2 3.1 3.5 3.4 3.3 3.3 3.7 3.6 3.5 3.4 3.8 3.7 3.6 3.5 3.9 3.9 3.8 3.7 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 9-9 -9 Heating capacity (cont.) Unit size 015 018 024 Outdoor air temp. °CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.1 3.3 3.6 3.7 3.9 4.1 4.3 4.5 4.7 4.8 5.0 5.2 5.2 5.2 5.2 5.2 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 5.0 5.3 5.7 5.8 6.2 6.5 6.8 7.1 7.4 7.7 8.0 8.3 8.3 8.3 8.3 8.3 Indoor air temp. °CDB 18.0 20.0 22.0 SHC SHC SHC 3.1 3.0 2.9 3.3 3.2 3.1 3.5 3.4 3.3 3.6 3.5 3.4 3.8 3.7 3.6 4.0 3.9 3.8 4.2 4.1 4.0 4.4 4.3 4.2 4.6 4.5 4.4 4.7 4.6 4.5 4.9 4.8 4.7 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 3.9 3.8 3.7 4.1 4.0 3.9 4.4 4.3 4.2 4.5 4.4 4.3 4.8 4.7 4.6 5.0 4.9 4.8 5.3 5.2 5.0 5.5 5.4 5.3 5.8 5.6 5.5 6.0 5.9 5.7 6.2 6.1 5.9 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 4.9 4.8 4.7 5.2 5.1 5.0 5.6 5.5 5.3 5.7 5.6 5.5 6.1 5.9 5.8 6.4 6.2 6.1 6.7 6.6 6.4 7.0 6.9 6.7 7.3 7.1 7.0 7.6 7.4 7.3 7.9 7.7 7.5 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 24.0 SHC 2.9 3.0 3.2 3.3 3.5 3.7 3.9 4.1 4.2 4.4 4.6 4.8 4.8 4.8 4.8 4.8 3.6 3.8 4.1 4.2 4.4 4.7 4.9 5.1 5.3 5.6 5.8 6.0 6.0 6.0 6.0 6.0 4.6 4.9 5.2 5.3 5.6 5.9 6.2 6.5 6.8 7.1 7.3 7.6 7.6 7.6 7.6 7.6 9-9 -10 9-9-5. Air throw distance chart MMK-AP0071H, AP0091H, AP0121H Horizontal discharge Initial speed High wind: 5.0m/s Med. wind: 4.4m/s Horizontal discharge 5 Air speed (m/s) Air speed (m/s) 5 4 3 2 1 0 MMK-AP0151H, AP0181H 1 2 3 4 5 6 7 Initial speed High wind: 5.0m/s Med. wind: 4.4m/s 4 3 2 1 0 Horizontal throw (m) 1 2 3 4 5 6 7 Horizontal throw (m) MMK-AP0241H Air speed (m/s) Horizontal discharge Initial speed High wind: 5.0m/s Med. wind: 4.4m/s 5 4 3 2 1 0 1 2 3 4 5 6 7 Horizontal throw (m) 9-9 -11 (Revised edition in 7.Apr.2006) 9-9-6. Sound characteristics (NC-Curve) MMK -AP0071H, AP0091H, AP0121H MMK-AP0071H, Fan Tap Sound pressure level(dB(A)) [Measuring location] H M L 39 34 31 Octave band sound pressure level (dB) 90 Microphone 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 M M 30 Approximate threshold of hearing for continuous noise 20 NC-30 L NC-20 10 60 125 250 500 1000 2000 4000 8000 Octave band frequency(Hz) MMK -AP0151H, AP0181H MMK-AP0151H, Fan Tap Sound pressure level(dB(A)) MMK -AP0241H MMK-AP0241H H M L 42 38 35 Fan Tap Sound pressure level(dB(A)) Octave band sound pressure level (dB) Octave band sound pressure level (dB) M L 38 35 90 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 H M 30 NC-30 L 20 H 42 Approximate threshold of hearing for continuous noise NC-20 10 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 H M 30 NC-30 L Approximate threshold of hearing for continuous noise 20 NC-20 10 63 125 250 500 1000 2000 4000 8000 63 Octave band frequency(Hz) 125 250 500 1000 2000 4000 Octave band frequency(Hz) 9-9 -12 (Revised edition in 7.Apr.2006) 8000 9-9-7. Accessories Apperarance Standard accessories Part name Qty Shape Use Part name Qty Shape Use Installation Manual 1 (Be sure to hand over to customer) Installation pattern 1 Used for drilling holes and positioning installation plate Heat Insulating pipe 2 For heat insulating of pipe connecting section Screw cap 4 Cover on fixing screw at side plate Wood screw Ø5.1 x 45 12 Used to fix installation plate Bundling band 4 Used to fix attached pipe heat insulating material Installation plate 1 Used to install indoor unit wall unit Optional accessories Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-9 -13 9-10-1. Specifications 50Hz Specifications (50Hz) Model name MMK- AP0072H AP0092H AP0122H (kW) 2.2/2.5 2.8/3.2 3.6/4.0 Cooling/Heating capacity (Note 1) 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) Power supply Electrical characteristics (A) 0.17 0.18 0.19 (kW) 0.017 0.018 0.019 (A) 0.22 0.23 0.24 Running current Power consumption Starting current Appearance Outer dimension Suction grille and side panel Moon white Discharge grille Moon white Bottom surface Moon white Height x Width x Depth Total weight (mm) 275 x 790 x 208 (kg) 11 Finned tube Heat exchanger Non-flammable insulation Soundproof/Heat-insulating material Cross-flow fan Fan Fan unit Standard air flow (High/Mid/Low) Motor outlet (m3/h) 480/420/360 510/450/360 540/450/360 30 (W) Standard filter (Simple filter) Air filter Wireless remote controller (WH-H2UE, Packed with indoor unit) Controller Gas side Connecting Liquid side pipe Drain port (mm) O / 9.5 (mm) O / 6.4 (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) 16 (Polyvinyl chloride tube) 35/32/29 36/33/29 PMV Kit 37/33/29 Available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note 3 : Wireless remote controller is packed with indoor unit. Wired remote controller (RBC-AMT31E, RBC-AS21E2) can be also connected. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-10 -1 60Hz Specifications (60Hz) Model name MMK- AP0072H AP0092H AP0122H (kW) 2.2/2.5 2.8/3.2 3.6/4.0 Cooling/Heating capacity (Note 1) 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Power supply Electrical characteristics Running current Power consumption (A) 0.18 0.19 0.20 (kW) 0.017 0.018 0.019 (A) 0.22 0.23 0.24 Starting current Appearance Outer dimension Suction grille and side panel Moon white Discharge grille Moon white Bottom surface Moon white Height x Width x Depth Total weight (mm) 275 x 790 x 208 (kg) 11 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Cross-flow fan Fan Fan unit Standard air flow (High/Mid/Low) Motor outlet (m3/h) 480/420/360 510/450/360 540/450/360 30 (W) Standard filter (Simple filter) Air filter Wireless remote controller (WH-H2UE, Packed with indoor unit) Controller Gas side Connecting Liquid side pipe Drain port (mm) O / 9.5 (mm) O / 6.4 (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) 16 (Polyvinyl chloride tube) 35/32/29 36/33/29 37/33/29 Available PMV Kit Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note 3 : Wireless remote controller is packed with indoor unit. Wired remote controller (RBC-AMT31E, RBC-AS21E2) can be also connected. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-10 -2 9-10-2. Dimension MMK-AP0072H, AP0092H, AP0122H Air inlet part 790 275 275 208 275 208 Knockout 60 48 Air outlet gril 6 6 60 48 Knockout 54.5 60 60 48 48 208 790 54.5 208 790 275 790 Hock for insulation plate Drain pipe 321 Refrigerant pipe connecting port Liquid side O / 6.4 Refrigerant pipe connecting port Gas side O / 9.5 100mm or more 170mm or more *300mm or more 170mm or more Wired remote controller RBC-AMT31E *(For attached Flow Selector unit of heat recovery model) Space required for service Simple wired remote controller RBC-AS21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Note: All dimensions are in mm. 9-10 -3 9-10-3. Wiring diagram Model: MMK-AP0072H, AP0092H, AP0122H 9-10 -4 9-10-4. Sensible capacity table (MMD-AP***H) Cooling capacity Unit size 007 009 012 Outdoor air temp. ˚CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0˚CWB 23˚CDB TC SHC 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 1.9 1.5 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.4 1.8 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.2 2.3 3.1 2.2 18.0˚CWB 26˚CDB TC SHC 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.1 1.7 2.0 1.6 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.7 2.0 2.6 1.9 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.5 2.5 3.4 2.5 3.4 2.4 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0˚CWB 20.0˚CWB 22.0˚CWB 24.0˚CWB 27˚CDB 28˚CDB 30˚CDB 32˚CDB TC SHC TC SHC TC SHC TC SHC 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 2.2 1.7 2.2 1.7 2.4 1.7 2.5 1.6 2.1 1.6 2.2 1.6 2.3 1.6 2.4 1.5 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 2.7 2.0 2.8 2.0 3.0 1.9 3.1 1.9 2.7 1.9 2.8 1.9 2.9 1.9 3.1 1.8 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 3.5 2.5 3.6 2.4 3.8 2.4 4.0 2.4 3.5 2.4 3.6 2.4 3.8 2.3 3.9 2.3 9-10 -5 Heating capacity Unit size 007 009 012 Outdoor air temp. ˚CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.6 2.6 2.6 2.6 2.0 2.1 2.3 2.3 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.3 3.3 3.3 3.3 2.5 2.7 2.8 2.9 3.1 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.2 4.2 4.2 4.2 SHC : Sensible Heat Capacity (kW) Indoor air temp. ˚CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 1.5 1.5 1.5 1.4 1.6 1.6 1.6 1.5 1.7 1.7 1.7 1.6 1.8 1.8 1.7 1.7 1.9 1.9 1.8 1.8 2.0 2.0 1.9 1.9 2.1 2.0 2.0 1.9 2.2 2.1 2.1 2.0 2.3 2.2 2.2 2.1 2.4 2.3 2.3 2.2 2.5 2.4 2.4 2.3 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.0 1.9 1.9 1.8 2.1 2.1 2.0 1.9 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.1 2.4 2.4 2.3 2.3 2.6 2.5 2.4 2.4 2.7 2.6 2.6 2.5 2.8 2.7 2.7 2.6 2.9 2.9 2.8 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 2.9 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 2.5 2.4 2.3 2.3 2.6 2.6 2.5 2.4 2.8 2.7 2.7 2.6 2.9 2.8 2.7 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 3.0 3.3 3.3 3.2 3.1 3.5 3.4 3.3 3.3 3.7 3.6 3.5 3.4 3.8 3.7 3.6 3.5 3.9 3.9 3.8 3.7 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 9-10 -6 9-10-5. Air throw distance chart Model : MMK-AP0072H, AP0092H, AP0122H Horizontal discharge Initial speed High wind : 4.5m/s Med wind : 3.7m/s Low wind : 3.2m/s Air speed (m/s) 5 4 High Mid Low 3 2 1 0 0 1 2 3 4 Horizontal throw (m) 9-10 -7 5 6 7 9-10-6. Sound characteristics (NC-Curve) Model : MMK-AP0072H, AP0092H, AP0122H 1m 1m Microphone MMK-AP0072H Fan tap H M L Sound pressure level (dB(A)) 35 32 29 Octave band sound pressure level (dB) 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 20 10 20-75 NC-30 Audibility limits of continuous white level 75-150 NC-20 150-300 300-600 600-1200 1200-2400 Octave band frequency (Hz) 9-10 -8 2400-4800 4800-10000 MMK-AP0092H Fan tap H M L Sound pressure level (dB(A)) 36 33 29 Octave band sound pressure level (dB) 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continuous white level 10 20-75 75-150 NC-20 150-300 300-600 600-1200 1200-2400 2400-4800 4800-10000 Octave band frequency (Hz) MMK-AP0122H Fan tap H M L Sound pressure level (dB(A)) 35 33 29 Octave band sound pressure level (dB) 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 20 10 20-75 NC-30 Audibility limits of continuous white level 75-150 NC-20 150-300 300-600 600-1200 1200-2400 Octave band frequency (Hz) 9-10 -9 2400-4800 4800-10000 9-10-7. Accessories Apperarance Standard accessories Part No. Part name (Qty) 1 Part No. Part name (Qty) 3 Installation plate × 1 2 Part name (Qty) 5 Battery × 2 Mounting screw Ø4 × 25 x 6 4 Wireless remote controller × 1 Part No. 6 Remote controller holder × 1 Optional accessories Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-10 -10 Pan head wood screw Ø3.1 × 16 × 2 9-11-1. Specifications 50Hz Specifications (50Hz) Model name Cooling/Heating capacity (Note 1) MML- AP0071H AP0091H AP0121H AP0151H AP0181H AP0241H (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) Power supply (A) 0.26 0.43 0.47 (kW) 0.056 0.092 0.102 Power factor (%) 94 93 94 Starting current (A) 0.60 0.80 1.10 Running current Electrical characteristics Power consumption Silky shade (1Y8.5/0.5) Appearance Outer dimension Height x Width x Depth 630 x 950 x 230 (mm) Total weight 37 (kg) 40 Finned tube Heat exchanger Non-flammable insulation Soundproof/Heat-insulating material Centrifugal fan Fan Fan unit Standard air flow (High/Mid/Low) Motor outlet 40 (m3/h) 480/420/360 900/780/650 1,080/930/780 45 (W) 70 Standard filter (Simple filter) Air filter Remote controller Controller Gas side Connecting Liquid side pipe O / 9.5 (mm) (dB(A)) O / 15.9 O / 9.5 O / 6.4 (mm) Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) O / 12.7 20 (Polyvinyl chloride tube) 39/37/35 45/41/38 49/44/39 Available PMV Kit Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-11 -1 60Hz Specifications (60Hz) Model name Cooling/Heating capacity (Note 1) MML- AP0071H AP0091H AP0121H AP0151H AP0181H AP0241H (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 Power supply 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Running current Electrical characteristics (A) 0.25 0.44 0.53 (kW) 0.053 0.092 0.113 Power factor (%) 96 95 97 Starting current (A) 0.60 0.80 1.10 Power consumption Silky shade (1Y8.5/0.5) Appearance Outer dimension Height x Width x Depth Total weight (mm) 630 x 950 x 230 37 (kg) 40 Finned tube Heat exchanger Soundproof/Heat-insulating material Non-flammable insulation Fan Fan unit Centrifugal fan Standard air flow (High/Mid/Low) Motor outlet (m3/h) 480/420/360 900/780/650 45 (W) Air filter 70 Standard filter (Simple filter) Controller Connecting pipe 1,080/930/780 Remote controller Gas side (mm) Liquid side (mm) Drain port Sound pressure level (Note 2) (High/Mid/Low) O / 9.5 O / 12.7 O / 6.4 (Nominal dia. mm) (dB(A)) O / 15.9 O / 9.5 20 (Polyvinyl chloride tube) 39/37/35 45/41/38 PMV Kit 49/44/39 Available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 9-11 -2 O O O 9-11-2. Dimension MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H Lower refrigerant piping port (50 X 100 knockout hole) 130 Fixing hole (Floor) (2-O / 10) Operation switch section (Sold separately) Fixing hole (Wall) (Two off knockout holes O / 10-O/ 20) Air discharge port Hole fixing wall (2-10 X 24 long hole) Air suction port ( left100 side ) Refrigerant pipe port (50 X 100 knockout hole on both sides) Earth screw (M6) Refrigerant pipe port (O / 130 knockout hole) Power supply cord hole (O / 26 knockout on both sides) Wired remote controller RBC-AMT31E Dimensions A B AP0071H, AP0091H, AP0121H O / 9.5 O / 6.4 AP0151H, AP0181H O / 12.7 O / 6.4 AP0241H O / 15.9 O / 9.5 Model MML- Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Refrigerant pipe connecting port (Liquid side O / B) Refrigerant pipe connecting port (Gas side O / A) Drain pipe connecting port (O / 20) 500 (Front side) or more 300 or more 1000 or more Positional Space required for service Figure shows piping at the left side drawing of piping Wall Wall (Front side) Note: All dimensions are in mm. 9-11 -3 TR CN066 (WHI) 1 1 2 2 RED Closed-end connector WHI Power supply single phase 220-240V 50Hz 220V 60Hz R(L) S(N) Indoor unit earth screw 1 1 3 3 WHI CN067 (BLK) RED 3 3 1 1 3 3 1 1 P301 (BLK) FUSE (YEL) CN309 (GRY) CN304 1 2 1 2 CN040 (BLU) Outdoor unit U1 U2 U1 U2 B 1 2 1 2 CN1 A 3 3 2 1 1 L X Y 1 2 1 2 CN03(RED) CN02 (BLU) CN074 1 (WHI) 1 RY002 CN068 (BLU) 1 3 3 3 LM 1 1 2 3 4 5 6 1 2 3 4 5 6 Sub P.C. board MCC-1520 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 PMV 1 2 3 4 5 6 CN082 1 2 3 4 5 6 (BLU) TR CN01 (WHI) CN02 (YEL) 1 2 3 4 5 6 T10 CN061 (YEL) 1 2 3 4 5 CN081 (BLK) OPTION Symbol FM RC TR TA TC1,TC2,TCJ RY001 RY002 RY004 RY005~007 PMV 1 2 3 4 5 6 1 2 CN060 (WHI) 1 2 CN070 (WHI) RED : RED WHI : WHITE YEL :YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication Parts name Fan motor Running capacitor Transformer Indoor temp sensor Temp sensor Louver control relay Drain control relay Heater control relay Fan motor control relay Pulse motor valve FILTER 1 EXCT 2 TC1 TC2 TCJ TA CN073 (RED) 1 2 PNL 3 1 1 2 2 CN100 (BRN) CN080 (GRN) 1 1 2 2 1 1 2 2 1 1 2 2 CN101 (BLK) CN102 (RED) CN104 (YEL) FS 1 3 CN030 1 2 3 (RED) FAN DRIVE CN032 (WHI) Control P.C. board for Indoor unit MCC-1403 CN075 (WHI) CN033 3 (GRN) Power supply circuit RY001 DP 6 4 3 1 2 5 6 4 3 1 2 5 PMV indicates the terminal block. the letter inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring on site. Indicates the control p.c. board. 3. 1. MCC-1401 Network Adapter (Option) UL CN01(WHI) 1 2 1 2 1 2 3 4 5 CN050 (WHI) RY005 RY006 M Remote Controller 1 2 3 RC 1 3 RY007 H RED BLK ORN BLU YEL FAN 7 5 3 1 CN083 9 (WHI) 9 7 5 3 1 CN041 (BLU) RY004 T5.0A 250V~ Flow selector unit earth screw Line Filter AC IN RC BLU 2 3 4 5 6 BLU 2 3 4 5 6 BLK 9-11 -4 BLK FM 9-11-3. Wiring diagram Model: MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H 9-11-4. Sensible capacity table (MML-AP***H) Cooling capacity Unit size 007 009 012 Outdoor air temp. ˚CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0˚CWB 23˚CDB TC SHC 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 1.9 1.2 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.4 1.4 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.1 1.9 3.1 1.9 18.0˚CWB 26˚CDB TC SHC 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.0 1.3 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.6 1.5 3.4 2.1 3.4 2.1 3.4 2.1 3.4 2.1 3.4 2.1 3.4 2.1 3.4 2.1 3.4 2.1 3.4 2.1 3.4 2.1 3.4 2.1 3.4 2.1 3.4 2.1 3.4 2.1 3.3 2.1 3.3 2.0 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0˚CWB 20.0˚CWB 22.0˚CWB 24.0˚CWB 27˚CDB 28˚CDB 30˚CDB 32˚CDB TC SHC TC SHC TC SHC TC SHC 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.2 1.4 2.4 1.4 2.5 1.3 2.1 1.3 2.2 1.3 2.3 1.3 2.4 1.3 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.7 1.6 2.8 1.6 3.0 1.6 3.1 1.5 2.7 1.5 2.8 1.5 2.9 1.5 3.1 1.5 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.5 2.1 3.6 2.1 3.8 2.1 4.0 2.0 3.4 2.1 3.5 2.1 3.7 2.0 3.9 2.0 3.4 2.0 3.5 2.0 3.7 2.0 3.8 1.9 9-11 -5 Cooling capacity (cont.) Unit size 015 018 024 Outdoor air temp. ˚CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0˚CWB 23˚CDB TC SHC 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.0 2.6 3.9 2.5 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.0 3.2 4.9 3.1 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.3 4.2 6.2 4.0 18.0˚CWB 26˚CDB TC SHC 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.3 2.8 4.2 2.6 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.3 3.4 5.2 3.3 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.7 4.4 6.6 4.2 Indoor air temp. 19.0˚CWB 27˚CDB TC SHC 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.4 2.7 4.3 2.6 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.5 3.4 5.4 3.3 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.0 4.4 6.8 4.2 20.0˚CWB 28˚CDB TC SHC 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.5 2.7 4.4 2.6 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.7 3.4 5.5 3.3 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.2 4.4 7.0 4.2 9-11 -6 22.0˚CWB 30˚CDB TC SHC 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.8 2.7 4.7 2.6 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.0 3.4 5.9 3.3 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.6 4.4 7.4 4.2 24.0˚CWB 32˚CDB TC SHC 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.0 2.7 4.9 2.5 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.3 3.3 6.1 3.2 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 7.9 4.3 7.8 4.1 Heating capacity Unit size 007 009 012 Outdoor air temp. ˚CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.6 2.6 2.6 2.6 2.0 2.1 2.3 2.3 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.3 3.3 3.3 3.3 2.5 2.7 2.8 2.9 3.1 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.2 4.2 4.2 4.2 SHC : Sensible Heat Capacity (kW) Indoor air temp. ˚CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 1.5 1.5 1.5 1.4 1.6 1.6 1.6 1.5 1.7 1.7 1.7 1.6 1.8 1.8 1.7 1.7 1.9 1.9 1.8 1.8 2.0 2.0 1.9 1.9 2.1 2.0 2.0 1.9 2.2 2.1 2.1 2.0 2.3 2.2 2.2 2.1 2.4 2.3 2.3 2.2 2.5 2.4 2.4 2.3 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.0 1.9 1.9 1.8 2.1 2.1 2.0 1.9 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.1 2.4 2.4 2.3 2.3 2.6 2.5 2.4 2.4 2.7 2.6 2.6 2.5 2.8 2.7 2.7 2.6 2.9 2.9 2.8 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 2.9 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 2.5 2.4 2.3 2.3 2.6 2.6 2.5 2.4 2.8 2.7 2.7 2.6 2.9 2.8 2.7 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 3.0 3.3 3.3 3.2 3.1 3.5 3.4 3.3 3.3 3.7 3.6 3.5 3.4 3.8 3.7 3.6 3.5 3.9 3.9 3.8 3.7 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 9-11 -7 Heating capacity (cont.) Unit size 015 018 024 Outdoor air temp. ˚CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.1 3.3 3.6 3.7 3.9 4.1 4.3 4.5 4.7 4.8 5.0 5.2 5.2 5.2 5.2 5.2 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 5.0 5.3 5.7 5.8 6.2 6.5 6.8 7.1 7.4 7.7 8.0 8.3 8.3 8.3 8.3 8.3 Indoor air temp. ˚CDB 18.0 20.0 22.0 SHC SHC SHC 3.1 3.0 2.9 3.3 3.2 3.1 3.5 3.4 3.3 3.6 3.5 3.4 3.8 3.7 3.6 4.0 3.9 3.8 4.2 4.1 4.0 4.4 4.3 4.2 4.6 4.5 4.4 4.7 4.6 4.5 4.9 4.8 4.7 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 3.9 3.8 3.7 4.1 4.0 3.9 4.4 4.3 4.2 4.5 4.4 4.3 4.8 4.7 4.6 5.0 4.9 4.8 5.3 5.2 5.0 5.5 5.4 5.3 5.8 5.6 5.5 6.0 5.9 5.7 6.2 6.1 5.9 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 4.9 4.8 4.7 5.2 5.1 5.0 5.6 5.5 5.3 5.7 5.6 5.5 6.1 5.9 5.8 6.4 6.2 6.1 6.7 6.6 6.4 7.0 6.9 6.7 7.3 7.1 7.0 7.6 7.4 7.3 7.9 7.7 7.5 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 24.0 SHC 2.9 3.0 3.2 3.3 3.5 3.7 3.9 4.1 4.2 4.4 4.6 4.8 4.8 4.8 4.8 4.8 3.6 3.8 4.1 4.2 4.4 4.7 4.9 5.1 5.3 5.6 5.8 6.0 6.0 6.0 6.0 6.0 4.6 4.9 5.2 5.3 5.6 5.9 6.2 6.5 6.8 7.1 7.3 7.6 7.6 7.6 7.6 7.6 9-11 -8 9-11-5. Air throw distance chart High wind 2 Med. wind Low wind 1 0 1 2 3 4 5 6 Distance from discharge grille (m) 7 3 High wind Med. wind Low wind 2 1 0 1 2 3 4 MML-AP0181H, AP0241H Air speed (m/s) 3 MML-AP0121H, AP0151H Air speed (m/s) Air speed (m/s) MML-AP0071H, AP0091H 5 6 7 Distance from discharge grille (m) 4 High wind 3 Med. wind 2 Low wind 1 0 1 2 3 4 5 6 7 Distance from discharge grille (m) 9-11 -9 8 9-11-6. Sound characteristics (NC-Curve) [Measuring location] Microphon Air outlet 1m 1m MML-AP0071H,MML-AP0091H Fan tap H 39 L Fan tap H M L 35 Sound pressure level (dB(A)) 45 41 38 M 37 90 90 80 80 70 NC- 7 0 60 NC- 6 0 50 NC- 5 0 40 NC- 4 0 H 30 M Oct ave band sound pressure level (dB) Oct ave band sound pressure level (dB) Sound pressure level (dB(A)) MML-AP0121H,MML-AP0151H NC- 3 0 L 20 NC- 7 0 60 NC- 6 0 50 NC- 5 0 H M 30 NC- 3 0 L Approximate threshold of hearing for continuous noise NC- 2 0 10 10 63 125 250 500 1000 2000 4000 Octave band center frequency (Hz) 8000 MML-AP0181H,MML-AP0241H Fan tap H M L Sound pressure level (dB(A)) 49 44 39 90 80 Oct ave band sound pressure level (dB) NC- 4 0 40 20 NC- 2 0 Approximate threshold of hearing for continuous noise 70 70 NC- 7 0 60 NC- 6 0 50 NC- 5 0 H 40 NC- 4 0 M L 30 20 Approximate threshold of hearing for continuous noise NC- 3 0 NC- 2 0 10 63 125 250 500 1000 2000 4000 Octave band center frequency (Hz) 8000 9-11 -10 63 125 250 500 1000 2000 4000 Octave band center frequency (Hz) 8000 9-11-7. Accessories Apperarance Standard accessories Part name Qty Installation Manual 1 Heat insulation 2 Shape Use Part name Bushing Qty 1 For insulating the indoor unit pipe connections Optional accessories Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-11 -11 Shape Use For installation in the wire knockout 9-12-1. Specifications 50Hz Specifications (50Hz) Model name Cooling/Heating capacity (Note 1) MML- AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 Power supply 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) (A) 0.25 0.45 0.46 (kW) 0.056 0.090 0.095 Power factor (%) 97 87 90 Starting current (A) 0.60 0.80 1.00 Running current Electrical characteristics Power consumption Zinc hot dipping steel plate Appearance Outer dimension Height x Width x Depth Total weight (mm) 600 x 745 x 220 600 x 1,045 x 220 (kg) 21 29 Finned tube Heat exchanger Non-flammable insulation Soundproof/Heat-insulating material Centrifugal fan Fan Standard air flow (High/Mid/Low) (m3/h) 460/400/300 740/600/490 950/790/640 Fan unit Motor (W) 19 70 Static pressure range (kPa) 0 Air filter Standard filter (Simple filter) Controller Remote controller Gas side Connecting Liquid side pipe (mm) (mm) Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) O / 9.5 O / 12.7 O / 6.4 O / 15.9 O / 9.5 20 (Polyvinyl chloride tube) 36/34/32 PMV Kit 42/37/33 Not available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-12 -1 60Hz Specifications (60Hz) Model name Cooling/Heating capacity (Note 1) MML- AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 Power supply 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Running current (A) 0.27 0.46 0.51 (kW) 0.058 0.096 0.110 Power factor (%) 98 95 98 Starting current (A) 0.60 0.80 1.00 Power consumption Electrical characteristics Appearance Zinc hot dipping steel plate Outer dimension Height x Width x Depth Total weight (mm) 600 x 745 x 220 600 x 1,045 x 220 (kg) 21 29 Finned tube Heat exchanger Non-flammable insulation Soundproof/Heat-insulating material Fan Fan unit Centrifugal fan Standard air flow (High/Mid/Low) Motor (m3/h) 460/400/300 (W) Static pressure range 19 70 (kPa) 0 Standard filter (Simple filter) Air filter Remote controller Controller Connecting pipe 950/790/640 740/600/490 Gas side (mm) Liquid side (mm) Drain port O / 9.5 O / 12.7 O / 6.4 (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) O / 15.9 O / 9.5 20 (Polyvinyl chloride tube) (dB(A)) 36/34/32 42/37/33 Not available PMV Kit Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O 9-12 O O O O -2 (Revised Edition in 7.Apr.2006) 9-12-2. Dimension MML-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH Fixing hole (Floor) (Discharge port size in flange) Ceiling board section 150 or more (Service space) 150 or more (Air discharge port size in flange) (Service space) 2-O / 4.7 hole (Left/right side each) Expansion valve box G-O / 4.7 hole (Front side and rear side each) 4-O / 15 hole (For mounting rear side) 2-12 5 18 hole Fixing hole (Floor) Name No. 1 Pipe connecting port at liquid side (O / E) 2 Pipe connecting port at gas side (O / F) 3 Drain pipe connecting port (20A) 5 Air filter B C AP0151BH, AP0181BH 910 880 850 AP0241BH D E 4 6.4 7 9.5 F G 9.5 5 12.7 15.9 8 Wired remote controller RBC-AMT31E4 Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 120 Electric parts box (Earth terminal on the inside) A Model MML- AP0071BH, AP0091BH, AP0121BH 610 580 550 2.7 4 Dimensions Weekly timer application RBC-AMT31E and RBC-EXW21E2 120 16 Note: All dimensions are in mm. 9-12 -3 9-12 -4 WHI RC B Outdoor unit 1 2 1 2 CN1 Remote Controller A X Y MCC-1401 CN03(RED) CN02 (BLU) 1 1 2 2 CN03 (RED) CN041 (BLU) 1 2 3 1 3 1 2 1 2 RY007 H indicates the terminal block. the letter inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring on site. 3. Indicates the control p.c. board. 1. 3 3 2 1 1 2 4 5 6 3 L UL CN074 1 (WHI) 1 RY002 RED : RED WHI : WHITE YEL :YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication 1 2 3 4 5 CN050 (WHI) RY005 RY006 M RED BLK ORN BLU YEL FAN 7 5 3 1 CN068 1 CN083 9 (WHI) 9 (BLU) 1 7 5 3 1 2 4 5 6 3 CN040 (BLU) CN044 (BRW) 1 2 EMG CN066 (WHI) (BLK) CN067 T5.0A 250V~ FUSE (YEL) CN309 (GRY) CN304 RY004 RC 1 2 3 3 3 3 AC IN 1 1 1 1 3 1 RED FM R301 (BLK) GRN Network adapter (Option) CN01(WHI) 1 2 1 2 RED BLK ORN BLU YEL FAN 7 5 3 1 CN083 9 (WHI) 9 7 5 3 1 WHI RED WHI FM 1 3 2 4 5 6 For AP0071BH,AP0091BH,AP0121BH U1 U2 1 2 1 2 GRN U1 U2 TR Closed-end connector Flow selector unit earth screw RED R(L) S(N) RED Power supply single phase 220-240V 50Hz 220V 60Hz Indoor unit earth screw WHI 1 3 2 4 5 6 3 3 3 3 CN082 (BLU) CN104 (YEL) CN030 (RED) 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) Symbol FM RC TR TA TC1,TC2,TCJ RY001 RY002 RY004 RY005~007 PMV TR 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) Sub P.C. board MCC-1520 CN061 (YEL) 1 2 3 4 5 6 CN075 (WHI) 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 Parts name Fan motor Running capacitor Transformer Indoor temp sensor Temp sensor Louver control relay Drain control relay Heater control relay Fan motor control relay Pulse motor valve OPTION FAN DRIVE CN060 (WHI) 1 2 3 4 5 6 1 2 CN032 (WHI) CN081 (BLK) FILTER 1 2 CN070 (WHI) TC2 TCJ TA 1 EXCT 2 1 2 PNL 3 1 1 2 3 3 1 1 2 2 1 1 2 2 1 1 2 2 CN073 (RED) CN080 (GRN) CN100 (BRW) CN101 (BLK) CN102 (RED) 1 2 3 4 5 6 1 2 3 4 5 6 PMV 1 3 1 2 3 Control P.C. board for undoor unit MCC-1403 3 CN033 3 (GRN) Power supply circuit RY001 1 1 6 4 3 1 2 5 6 4 3 1 2 5 PMV TC1 9-12-3. Wiring diagram Model: MML-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH 9-12-4. Sensible capacity table (MML-AP***BH) Cooling capacity Unit size 007 009 012 Outdoor air temp. ˚CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0˚CWB 23˚CDB TC SHC 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 1.9 1.2 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.4 1.4 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.2 2.0 3.1 2.0 18.0˚CWB 26˚CDB TC SHC 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.1 1.4 2.0 1.3 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.7 1.6 2.6 1.5 3.5 2.2 3.5 2.2 3.5 2.2 3.5 2.2 3.5 2.2 3.5 2.2 3.5 2.2 3.5 2.2 3.5 2.2 3.5 2.2 3.5 2.2 3.5 2.2 3.5 2.2 3.5 2.2 3.4 2.2 3.4 2.1 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0˚CWB 20.0˚CWB 22.0˚CWB 24.0˚CWB 27˚CDB 28˚CDB 30˚CDB 32˚CDB TC SHC TC SHC TC SHC TC SHC 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.3 1.4 2.4 1.4 2.5 1.4 2.2 1.4 2.2 1.4 2.4 1.4 2.5 1.3 2.1 1.3 2.2 1.3 2.3 1.3 2.4 1.3 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.8 1.6 2.9 1.6 3.1 1.6 3.2 1.5 2.7 1.6 2.8 1.6 3.0 1.6 3.1 1.5 2.7 1.5 2.8 1.5 2.9 1.5 3.1 1.5 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.6 2.2 3.7 2.2 3.9 2.2 4.1 2.1 3.5 2.2 3.6 2.2 3.8 2.1 4.0 2.1 3.5 2.1 3.6 2.1 3.8 2.1 3.9 2.0 9-12 -5 Cooling capacity (cont.) Unit size 015 018 024 Outdoor air temp. ˚CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0˚CWB 23˚CDB TC SHC 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.0 2.6 3.9 2.5 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.0 3.2 4.9 3.1 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.3 4.2 6.2 4.0 18.0˚CWB 26˚CDB TC SHC 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.4 2.8 4.3 2.8 4.2 2.6 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.4 3.5 5.3 3.4 5.2 3.3 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.9 4.5 6.7 4.4 6.6 4.2 Indoor air temp. 19.0˚CWB 27˚CDB TC SHC 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.5 2.8 4.4 2.7 4.3 2.6 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.6 3.5 5.5 3.4 5.4 3.3 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.1 4.5 7.0 4.4 6.8 4.2 20.0˚CWB 28˚CDB TC SHC 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.6 2.8 4.5 2.7 4.4 2.6 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.7 3.4 5.5 3.3 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.2 4.4 7.0 4.2 9-12 -6 22.0˚CWB 30˚CDB TC SHC 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.8 2.7 4.7 2.6 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.0 3.4 5.9 3.3 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.6 4.4 7.4 4.2 24.0˚CWB 32˚CDB TC SHC 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.0 2.7 4.9 2.5 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.3 3.3 6.1 3.2 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 7.9 4.3 7.8 4.1 Heating capacity Unit size 007 009 012 Outdoor air temp. ˚CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.6 2.6 2.6 2.6 2.0 2.1 2.3 2.3 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.3 3.3 3.3 3.3 2.5 2.7 2.8 2.9 3.1 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.2 4.2 4.2 4.2 SHC : Sensible Heat Capacity (kW) Indoor air temp. ˚CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 1.5 1.5 1.5 1.4 1.6 1.6 1.6 1.5 1.7 1.7 1.7 1.6 1.8 1.8 1.7 1.7 1.9 1.9 1.8 1.8 2.0 2.0 1.9 1.9 2.1 2.0 2.0 1.9 2.2 2.1 2.1 2.0 2.3 2.2 2.2 2.1 2.4 2.3 2.3 2.2 2.5 2.4 2.4 2.3 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.6 2.5 2.4 2.4 2.0 1.9 1.9 1.8 2.1 2.1 2.0 1.9 2.2 2.2 2.1 2.1 2.3 2.2 2.2 2.1 2.4 2.4 2.3 2.3 2.6 2.5 2.4 2.4 2.7 2.6 2.6 2.5 2.8 2.7 2.7 2.6 2.9 2.9 2.8 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 2.9 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.0 2.5 2.4 2.3 2.3 2.6 2.6 2.5 2.4 2.8 2.7 2.7 2.6 2.9 2.8 2.7 2.7 3.0 3.0 2.9 2.8 3.2 3.1 3.0 3.0 3.3 3.3 3.2 3.1 3.5 3.4 3.3 3.3 3.7 3.6 3.5 3.4 3.8 3.7 3.6 3.5 3.9 3.9 3.8 3.7 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 4.1 4.0 3.9 3.8 9-12 -7 Heating capacity (cont.) Unit size 015 018 024 Outdoor air temp. ˚CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.1 3.3 3.6 3.7 3.9 4.1 4.3 4.5 4.7 4.8 5.0 5.2 5.2 5.2 5.2 5.2 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 5.0 5.3 5.7 5.8 6.2 6.5 6.8 7.1 7.4 7.7 8.0 8.3 8.3 8.3 8.3 8.3 Indoor air temp. ˚CDB 18.0 20.0 22.0 SHC SHC SHC 3.1 3.0 2.9 3.3 3.2 3.1 3.5 3.4 3.3 3.6 3.5 3.4 3.8 3.7 3.6 4.0 3.9 3.8 4.2 4.1 4.0 4.4 4.3 4.2 4.6 4.5 4.4 4.7 4.6 4.5 4.9 4.8 4.7 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 5.1 5.0 4.9 3.9 3.8 3.7 4.1 4.0 3.9 4.4 4.3 4.2 4.5 4.4 4.3 4.8 4.7 4.6 5.0 4.9 4.8 5.3 5.2 5.0 5.5 5.4 5.3 5.8 5.6 5.5 6.0 5.9 5.7 6.2 6.1 5.9 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 6.4 6.3 6.1 4.9 4.8 4.7 5.2 5.1 5.0 5.6 5.5 5.3 5.7 5.6 5.5 6.1 5.9 5.8 6.4 6.2 6.1 6.7 6.6 6.4 7.0 6.9 6.7 7.3 7.1 7.0 7.6 7.4 7.3 7.9 7.7 7.5 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 8.2 8.0 7.8 24.0 SHC 2.9 3.0 3.2 3.3 3.5 3.7 3.9 4.1 4.2 4.4 4.6 4.8 4.8 4.8 4.8 4.8 3.6 3.8 4.1 4.2 4.4 4.7 4.9 5.1 5.3 5.6 5.8 6.0 6.0 6.0 6.0 6.0 4.6 4.9 5.2 5.3 5.6 5.9 6.2 6.5 6.8 7.1 7.3 7.6 7.6 7.6 7.6 7.6 9-12 -8 9-12-5. Sound characteristics (NC-Curve) Sound level values shown are based on a measurement in a non resound room. Microphone MML-AP0071BH, AP0091BH, AP0121BH 50Hz H M L 60Hz Fan Tap M L A 36.0 34.0 32.0 Overall level A 36.0 34.0 32.0 (dB) C 41.7 40.2 37.9 (dB) C 41.6 39.8 38.1 (standard sound pressure 0.0002 µbar) Audibility limits of continuous white level (standard sound pressure 0.0002 µbar) Audibility limits of continuous white level Octave band center frequency (Hz) Octave band center frequency (Hz) MML-AP0151BH, AP0181BH Fan Tap 50Hz H M L 60Hz Fan Tap H M L Overall level A 36.0 34.0 32.0 Overall level A 36.0 34.0 32.0 (dB) C 41.4 40.0 38.8 (dB) C 41.4 40.0 39.0 (standard sound pressure 0.0002 µbar) Audibility limits of continuous white level Octave band sound pressure level (dB) Octave band sound pressure level (dB) H Overall level Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan Tap (standard sound pressure 0.0002 µbar) Audibility limits of continuous white level Octave band center frequency (Hz) Octave band center frequency (Hz) 9-12 -9 MML-AP0241BH Fan Tap 50Hz H M L 60Hz Fan Tap M L Overall level A 42.0 37.0 33.0 Overall level A 42.0 37.0 33.0 (dB) C 46.4 41.0 37.7 (dB) C 46.6 41.0 38.0 (standard sound pressure 0.0002 µbar) Audibility limits of continuous white level (standard sound pressure 0.0002 µbar) Octave band sound pressure level (dB) Octave band sound pressure level (dB) H Octave band center frequency (Hz) Audibility limits of continuous white level Octave band center frequency (Hz) 9-12 -10 9-12-6. Accessories Apperarance Standard accessories Part name Qty Shape Use Part name Qty Shape Use Drain receiver fixing screw 1 For fix the drain receiver Installation Manual 1 Heat insulation 2 For heat insulating the indoor unit pipe connections Drain hose 1 For water draining (Attaches to the drain receiver.) Drain pan 1 For water draining Heat insulated pipe 1 For insulating the drain receiver (Attaches to the drain receiver.) Drain filter 1 Drain filter (inside the drain receiver) Optional accessories Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-12 -11 9-13-1. Specifications 50Hz Specifications (50Hz) Model name MMF- AP0151H AP0181H AP0241H AP0271H AP0361H AP0481H (kW) 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 Cooling/Heating capacity (Note 1) Power supply 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.) Running current Electrical characteristics (A) 0.67 0.88 1.29 1.60 (kW) 0.150 0.190 0.280 0.350 Power factor (%) 97 Starting current (A) 0.90 Power consumption 1.10 Height x Width x Depth 1,750 x 600 x 210 (mm) Total weight (kg) 48 Non-flammable insulation Centrifugal fan Fan Motor 65 Finned tube Soundproof/Heat-insulating material Standard air flow (High/Mid/Low) 1,750 x 600 x 390 49 Heat exchanger Fan unit 2.10 1.70 W : Silky shade (1Y 8.5/0.5) Appearance Outer dimension 95 94 (m3/h) (W) 900/780/660 1,200/1,020/840 1,920/ 1,680/ 1,380 2,160/ 1,860/ 1,560 37 63 110 160 51/48/44 54/50/46 Standard filter (Simple filter) Air filter Remote controller Controller Gas side Connecting Liquid side pipe (mm) O / 12.7 O / 15.9 (mm) O / 6.4 O / 9.5 Drain port (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) 20 (Polyvinyl chloride tube) 46/43/38 49/45/40 Not available PMV Kit Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 9-13 -1 60Hz Specifications (60Hz) Model name Cooling/Heating capacity (Note 1) MMF- AP0151H AP0181H AP0241H AP0271H AP0361H AP0481H (kW) 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 Power supply Running current Electrical characteristics 1 phase 60Hz 220V (Separate power supply for indoor units is required.) (A) 0.67 0.90 1.37 1.75 (kW) 0.146 0.195 0.295 0.380 Power factor (%) 99 Starting current (A) 0.90 Power consumption 1.10 1.80 Height x Width x Depth (mm) (kg) Total weight 1,750 x 600 x 390 1,750 x 600 x 210 48 65 49 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Fan Centrifugal fan Fan unit Standard air flow (High/Mid/Low) (m3/h) (W) Motor 900/780/660 1,200/1,020/840 37 63 Air filter 1,920/1,680/1,380 2,160/1,860/1,560 110 160 51/48/44 54/50/46 Standard filter (Simple filter) Controller Connecting pipe 2.30 W : Silky Shade (1Y 8.5/0.5) Appearance Outer dimension 99 98 Remote controller Gas side (mm) O / 12.7 O / 15.9 Liquid side (mm) O / 6.4 O / 9.5 Drain port 20 (Polyvinyl chloride tube) (Nominal dia. mm) Sound pressure level (Note 2) (High/Mid/Low) (dB(A)) 46/43/38 49/45/40 PMV Kit Not available Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 9-13 -2 O O O 9-13-2. Dimension MMF-AP0151H, AP0181H, AP0241H, AP0271H Wall Dimensions ( Incase of installing distance is 50mm from wall ) Model Lower refrigerant piping port (50 x 120 Knockout hole) Installation plate Discharge port A B MMF-AP0151H, AP0181H O / 12.7 O / 6.4 MMF-AP0241H, AP0271H O / 15.7 O / 9.5 600 30 x 3 30 x 3 80 Wall Wall a b Wall Control part More Front than 500 Front More than 1000 Wall More than 200 Space required for service (In case of right side piping ) Control cover Wall Floor Refrigerant piping port (Both side) (O / 80 Knockout) Earth screw (M4) Drain hose Installation plate Suction port Refrigerant piping hole (Back side) (O / 130 Knockout ) Refrigerant piping position Refrigerant piping hole (Bottom side) (50 x 120 Knockout) Refrigerant piping joint (Gas side A) Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Refrigerant piping joint (Liquid side B) ( ) In case b 1773 2- lower hole For M8 Screw bolt or M8 Anchor bolt In case a 1770 Details of hole for back side piping Details of hole for lower side piping 4- lower hole M8 Screw bolt ( For or M8 Anchor bolt ) O / 130 Knockout 50 x 120 (Square opening) (For under surface piping) (For backside piping) Note: All dimensions are in mm. 9-13 -3 MMF-AP0361H, AP0481H Wall of installing distance is ( Incase ) 50mm from wall Lower refrigerant piping port (50 x 120 Knockout) Installation plate Discharge port 600 30 x 3 30 x 3 80 Wall Wall a b Wall Control part Control cover More Front than 500 Wall Front More than 1000 Wall More than 200 Space required for service (In case of right side piping ) Floor Refrigerant piping port (Both side) (O / 80 Knockout) Drain hose Earth screw (M4) Installation plate Dtain hose Suction port Refrigerant piping hole (Back side) (O / 130 Knockout) Refrigerant piping hole (Bottom side) (50 x 120 Knockout) Refrigerant piping position Refrigerant piping joint (Gas side O / 19) Wired remote controller RBC-AMT31E Gas side Liquid side Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Refrigerant piping joint (Liquid side O / 9.5) Details of hole for lower side piping In case b 1773 2- lower hole M8 Screw bolt ( For or M8 Anchor bolt ) In case a 1770 Details of hole for back side piping O / 130 Knockout 4- lower hole M8 Screw bolt ( For or M8 Anchor bolt ) (For backside piping) 50 x 120 (Square opening) (For under surface piping) Note: All dimensions are in mm. 9-13 -4 RED FM Closed-end connector 1 1 3 1 P301 (BLK) FUSE (YEL) CN309 1 2 1 2 CN040 (BLU) (BLK) CN067 Outdoor unit U1 U2 U1 U2 1 2 1 2 B 1 2 1 2 CN1 A 3 3 2 1 1 H MCC-1401 3 3 3 3. 1 1 LM 2 1 2 1 1 2 3 4 5 6 CN02 (YEL) 1 2 3 4 5 6 the letter inside indicates the terminal number. Indicates the control p.c. board. the wiring on site. TR 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) Sub P.C. board MCC-1520 CN061 (YEL) . 1 2 3 4 5 6 OPTION 1 2 CN060 (WHI) CN081 (BLK) CN070 (WHI) CN073 (RED) CN080 (GRN) CN100 (BRW) CN101 (BLK) CN102 (RED) CN104 (YEL) TC2 TCJ TA FILTER TC1 RED : RED WHI : WHITE YEL :YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication Parts name Fan motor Running capacitor Transformer Lover motor Indoor temp sensor Temp sensor Louver control relay Drain control relay Fan motor control relay Pulse motor valve 1 2 3 4 5 1 2 1 EXCT 2 1 2 PNL 3 3 3 1 1 1 1 2 2 1 1 2 2 1 1 2 2 PMV 1 2 3 4 5 6 CN082 1 2 3 4 5 6 (BLU) FAN DRIVE CN032 (WHI) PMV 6 4 3 1 2 5 6 4 3 1 2 5 Symbol FM RC TR LM TA TC1,TC2,TCJ RY001 RY002 RY005~007 PMV 1 2 3 4 5 6 CN075 (WHI) 1 2 3 4 5 6 1 2 3 4 5 6 FS 1 3 CN030 1 2 3 (RED) Control P.C. board for Indoor unit MCC-1403 LM 3 CN033 3 (GRN) Power supply circuit RY001 DP Indicates the terminal bolock, letter. X Y 1 2 1 2 CN03(RED) CN02 (BLU) CN074 1 (WHI) 1 RY002 Network Adapter (Option) CN01(WHI) 1 2 1 2 1 2 3 4 5 CN050 (WHI) UL CN068 (BLU) 1 2 . A dotted line and broken line indicate 1. L RY005 RY006 M Remote Controller 1 2 3 RC 1 3 RY007 RED BLK ORN BLU YEL FAN 7 5 3 1 CN083 9 (WHI) 9 7 5 3 1 CN041 (BLU) RY004 (GRY) CN304 T5.0A 250V~ Line Filter TR EMG CN066 (WHI) 1 2 CN044 (BRW) 1 2 3 3 3 3 AC IN 1 1 BRW Flow selector unit earth screw Power supply single phase 220-240V 50Hz 220V 60Hz R(L) S(N) Indoor unit earth screw WHI RC BLU 3 4 5 6 7 BLU 3 4 5 6 7 8 BLK 9-13 -5 BLK 1 1 9-13-3. Wiring diagram Model: MMF-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H, AP0561H 9-13-4. Sensible capacity table (MMF-AP***H) Cooling capacity Unit size 015 018 024 Outdoor air temp. ˚CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0˚CWB 23˚CDB TC SHC 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.0 3.1 3.9 3.0 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.0 3.8 4.9 3.6 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.3 4.9 6.2 4.7 18.0˚CWB 26˚CDB TC SHC 4.4 3.4 4.4 3.4 4.4 3.4 4.4 3.4 4.4 3.4 4.4 3.4 4.4 3.4 4.4 3.4 4.4 3.4 4.4 3.4 4.4 3.4 4.4 3.4 4.4 3.4 4.4 3.4 4.3 3.3 4.2 3.2 5.4 4.1 5.4 4.1 5.4 4.1 5.4 4.1 5.4 4.1 5.4 4.1 5.4 4.1 5.4 4.1 5.4 4.1 5.4 4.1 5.4 4.1 5.4 4.1 5.4 4.1 5.4 4.1 5.3 4.0 5.2 3.9 6.9 5.3 6.9 5.3 6.9 5.3 6.9 5.3 6.9 5.3 6.9 5.3 6.9 5.3 6.9 5.3 6.9 5.3 6.9 5.3 6.9 5.3 6.9 5.3 6.9 5.3 6.9 5.3 6.7 5.2 6.6 5.0 TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW) Indoor air temp. 19.0˚CWB 20.0˚CWB 22.0˚CWB 24.0˚CWB 27˚CDB 28˚CDB 30˚CDB 32˚CDB TC SHC TC SHC TC SHC TC SHC 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.5 3.4 4.6 3.4 4.9 3.4 5.1 3.3 4.4 3.3 4.5 3.3 4.8 3.3 5.0 3.2 4.3 3.2 4.4 3.2 4.7 3.2 4.9 3.1 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.6 4.1 5.8 4.1 6.1 4.1 6.4 4.0 5.5 4.0 5.7 4.0 6.0 4.0 6.3 3.9 5.4 3.9 5.5 3.9 5.9 3.8 6.1 3.7 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.1 5.3 7.3 5.3 7.7 5.3 8.1 5.1 7.0 5.2 7.2 5.2 7.6 5.1 7.9 5.0 6.8 5.0 7.0 5.0 7.4 4.9 7.8 4.8 9-13 -6 Cooling capacity (cont.) Unit size 027 036 048 Outdoor air temp. ˚CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 16.0˚CWB 23˚CDB TC SHC 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.1 5.5 7.0 5.2 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.0 7.4 9.8 7.1 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.5 9.2 12.2 8.8 18.0˚CWB 26˚CDB TC SHC 7.8 5.9 7.8 5.9 7.8 5.9 7.8 5.9 7.8 5.9 7.8 5.9 7.8 5.9 7.8 5.9 7.8 5.9 7.8 5.9 7.8 5.9 7.8 5.9 7.8 5.9 7.8 5.9 7.6 5.8 7.4 5.6 10.9 8.0 10.9 8.0 10.9 8.0 10.9 8.0 10.9 8.0 10.9 8.0 10.9 8.0 10.9 8.0 10.9 8.0 10.9 8.0 10.9 8.0 10.9 8.0 10.9 8.0 10.9 8.0 10.6 7.9 10.4 7.5 13.6 9.9 13.6 9.9 13.6 9.9 13.6 9.9 13.6 9.9 13.6 9.9 13.6 9.9 13.6 9.9 13.6 9.9 13.6 9.9 13.6 9.9 13.6 9.9 13.6 9.9 13.6 9.9 13.3 9.7 13.0 9.3 Indoor air temp. 19.0˚CWB 27˚CDB TC SHC 8.0 5.9 8.0 5.9 8.0 5.9 8.0 5.9 8.0 5.9 8.0 5.9 8.0 5.9 8.0 5.9 8.0 5.9 8.0 5.9 8.0 5.9 8.0 5.9 8.0 5.9 8.0 5.9 7.8 5.8 7.7 5.6 11.2 8.0 11.2 8.0 11.2 8.0 11.2 8.0 11.2 8.0 11.2 8.0 11.2 8.0 11.2 8.0 11.2 8.0 11.2 8.0 11.2 8.0 11.2 8.0 11.2 8.0 11.2 8.0 11.0 7.8 10.8 7.5 14.0 9.9 14.0 9.9 14.0 9.9 14.0 9.9 14.0 9.9 14.0 9.9 14.0 9.9 14.0 9.9 14.0 9.9 14.0 9.9 14.0 9.9 14.0 9.9 14.0 9.9 14.0 9.9 13.7 9.7 13.4 9.3 20.0˚CWB 28˚CDB TC SHC 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.1 5.8 7.9 5.6 11.5 8.0 11.5 8.0 11.5 8.0 11.5 8.0 11.5 8.0 11.5 8.0 11.5 8.0 11.5 8.0 11.5 8.0 11.5 8.0 11.5 8.0 11.5 8.0 11.5 8.0 11.5 8.0 11.3 7.8 11.1 7.5 14.4 9.9 14.4 9.9 14.4 9.9 14.4 9.9 14.4 9.9 14.4 9.9 14.4 9.9 14.4 9.9 14.4 9.9 14.4 9.9 14.4 9.9 14.4 9.9 14.4 9.9 14.4 9.9 14.1 9.7 13.8 9.3 9-13 -7 22.0˚CWB 30˚CDB TC SHC 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.5 5.7 8.4 5.5 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.0 7.8 11.7 7.5 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.0 9.6 14.6 9.2 24.0˚CWB 32˚CDB TC SHC 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 8.9 5.6 8.8 5.4 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.5 7.6 12.3 7.3 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 15.6 9.4 15.3 9.0 Heating capacity Unit size 015 018 024 Outdoor air temp. ˚CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 3.1 3.3 3.6 3.7 3.9 4.1 4.3 4.5 4.7 4.8 5.0 5.2 5.2 5.2 5.2 5.2 3.9 4.2 4.5 4.6 4.9 5.1 5.4 5.6 5.9 6.1 6.3 6.6 6.6 6.6 6.6 6.6 5.0 5.3 5.7 5.8 6.2 6.5 6.8 7.1 7.4 7.7 8.0 8.3 8.3 8.3 8.3 8.3 SHC : Sensible Heat Capacity (kW) Indoor air temp. ˚CDB 18.0 20.0 22.0 24.0 SHC SHC SHC SHC 3.1 3.0 2.9 2.9 3.3 3.2 3.1 3.0 3.5 3.4 3.3 3.2 3.6 3.5 3.4 3.3 3.8 3.7 3.6 3.5 4.0 3.9 3.8 3.7 4.2 4.1 4.0 3.9 4.4 4.3 4.2 4.1 4.6 4.5 4.4 4.2 4.7 4.6 4.5 4.4 4.9 4.8 4.7 4.6 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 5.1 5.0 4.9 4.8 3.9 3.8 3.7 3.6 4.1 4.0 3.9 3.8 4.4 4.3 4.2 4.1 4.5 4.4 4.3 4.2 4.8 4.7 4.6 4.4 5.0 4.9 4.8 4.7 5.3 5.2 5.0 4.9 5.5 5.4 5.3 5.1 5.8 5.6 5.5 5.3 6.0 5.9 5.7 5.6 6.2 6.1 5.9 5.8 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 6.4 6.3 6.1 6.0 4.9 4.8 4.7 4.6 5.2 5.1 5.0 4.9 5.6 5.5 5.3 5.2 5.7 5.6 5.5 5.3 6.1 5.9 5.8 5.6 6.4 6.2 6.1 5.9 6.7 6.6 6.4 6.2 7.0 6.9 6.7 6.5 7.3 7.1 7.0 6.8 7.6 7.4 7.3 7.1 7.9 7.7 7.5 7.3 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 8.2 8.0 7.8 7.6 9-13 -8 Heating capacity (cont.) Unit size 027 036 048 Outdoor air temp. ˚CWB -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 -15.0 -13.0 -11.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 SHC 5.6 6.0 6.4 6.6 7.0 7.3 7.7 8.0 8.4 8.7 9.0 9.4 9.4 9.4 9.4 9.4 7.8 8.3 8.9 9.1 9.7 10.2 10.7 11.1 11.6 12.1 12.6 13.0 13.0 13.0 13.0 13.0 10.0 10.7 11.4 11.7 12.4 13.0 13.6 14.3 14.9 15.5 16.1 16.7 16.7 16.7 16.7 16.7 Indoor air temp. ˚CDB 18.0 20.0 22.0 SHC SHC SHC 5.5 5.4 5.3 5.9 5.8 5.6 6.3 6.1 6.0 6.5 6.3 6.2 6.8 6.7 6.5 7.2 7.0 6.9 7.5 7.4 7.2 7.9 7.7 7.5 8.2 8.0 7.8 8.5 8.4 8.2 8.9 8.7 8.5 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 9.2 9.0 8.8 7.7 7.5 7.3 8.2 8.0 7.8 8.7 8.5 8.3 9.0 8.8 8.6 9.5 9.3 9.1 10.0 9.8 9.5 10.5 10.2 10.0 10.9 10.7 10.5 11.4 11.2 10.9 11.9 11.6 11.3 12.3 12.1 11.8 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 12.8 12.5 12.2 9.8 9.6 9.4 10.5 10.3 10.0 11.1 10.9 10.7 11.5 11.2 11.0 12.1 11.9 11.6 12.8 12.5 12.2 13.4 13.1 12.8 14.0 13.7 13.4 14.6 14.3 14.0 15.2 14.9 14.5 15.8 15.4 15.1 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 16.3 16.0 15.6 24.0 SHC 5.1 5.5 5.8 6.0 6.3 6.7 7.0 7.3 7.6 7.9 8.3 8.6 8.6 8.6 8.6 8.6 7.2 7.6 8.1 8.3 8.8 9.3 9.7 10.2 10.6 11.0 11.5 11.9 11.9 11.9 11.9 11.9 9.1 9.7 10.4 10.7 11.3 11.9 12.4 13.0 13.6 14.1 14.7 15.2 15.2 15.2 15.2 15.2 9-13 -9 9-13-5. Air throw distance chart MMF-AP0151H, AP0181H (m) (m) 2.7 MMF-AP0241H, AP0271H 2.7 0.5m/s 2.0 2.0 0.5m/s 1.5m/s 0.7m/s 1.0m/s 1.5m/s 1.0 1.0m/s 1.0 1 2 3 4 5 6 7 8 (m) MMF-AP0361H (m) 1 (m) 2.7 2 3 4 5 6 7 8 (m) MMF-AP0481H,AP0561H 2.7 2.0 1.5m/s 2.0m/s 0.5m/s 1.0m/s 2.0 1.5m/s 1.0 1.5m/s 1.5m/s 1.0m/s 1.0 1 2 3 4 5 6 7 8 (m) 1 9-13 -10 2 3 4 5 6 7 8 (m) 9-13-6. Accessories Apperarance Standard accessories Attached position Part name Upper part of main unit Bracket for fixing to wall Qty Shape Stored position 1 Installation Manual 1 Thermal insulator 2 Indoor unit Accessory bag Screw bolt Thermal insulator 4 (2) Base for transportation 2 Using 4 (2) screw bolts, fix to the base. Lower part of main unit Bracket for fixing to floor 2 Quantities in the above table are for MMF-AP0361, AP0481 and AP0561 models. The brackets for fixing to the floor are already mounted on the indoor unit. Optional accessories Remote controller Model Name Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Central remote controller TCB-SC642TLE2 ON-OFF controller TCB-CC163TLE2 9-13 -11 [1] Remote location ON/OFF control box Model Name Features Appearance TCB-IFCB-4E2 Start and stop of the air conditioner is possible by a external signal and indication of operation/alarm externally. Application Function Monitoring ON/OFF status (for indoor unit) Alarm status (system & indoor unit stop) ON/OFF command Air conditioner can be turned ON/OFF by external signals. The external ON/OFF signals will initiate the signals shown below. Operation Interface Display Remote Controller ON /OFF Non-voltage ON /OFF continious signal COM Dimension Outside view Inside view 200 Fix this control box to the place besides the indoor unit. 1 78 6- 5.5 mounting hole Approx. 300 78 22 66 63.6 6 Approx. 1500 22 78 78 170 5 146.9 3 22 156 2 4 22 Note : All dimensions are in mm (NOTE) Do not install the accessory parts at the following locations. 1. Location where combustible gas may leak 2. Location where direct sunlight shines 3. Location with high humidity such as bathroom, kitchen, etc. 4. Location with high levels of dust 5. Location where rain or dew drops such as outdoors 6. Location in 1m-range of a TV or radio Name No. Specification 1 Case unit 2 Case cover Galvanized steel 0.8t 3 Harness to connect indoor unit P.C. board CN61 connector 4 Harness for indication cable UL1015 AWG18 tip-insulation type butt connector 5 Harness for power supply 3-core, 0.75mm2 6 Harness for ON/OFF command UL1015 AWG18 tip-insulation type butt connector Galvanized steel 0.8t 9-14 -1 Panels and accessories Indoor unit type Accessory parts name Model 4-way Air Discharge Cassette Type Optional Super Long Life Filter TCB-LF1601UE2 High Efficiency Filter 65 TCB-UFM1601UE High Efficiency Filter 90 TCB-UFH1601UE Fresh air and Filter Chamber TCB-GFC1601UE2 Fresh air inlet Box TCB-GB1601UE2 Auxiliary fresh air Flange TCB-FF101URE2 Spacer for height adjustment TCB-SP1601UE Optional 2-way Air Discharge Cassette Type *** Fresh Air Chamber *** Fresh Air Intel Box *** Required accessory Ceiling panel Required accessory Ceiling panel 1-way Air Discharge Cassette Type Optional China market only AP0071-0121/AP0241-0301 AP0241-AP0301 use two pcs. TCB-UFM21BFCE AP0151-0181/AP0361-0481 AP0361-AP0481 use two pcs. TCB-UFM11BE AP0071-0121 TCB-UFM21BE AP0151-0181 TCB-UFM31BE AP0241-0301 TCB-UFM41BE AP0361-0481 TCB-UFH51BFCE TCB-UFH61BFCE AP0071-0121/AP0241-0301 AP0241-AP0301 use two pcs. AP0151-0181/AP0361-0481 AP0361-AP0481 use two pcs. TCB-UFH51BE AP0071-0121 TCB-UFH61BE AP0151-0181 TCB-UFH71BE AP0241-0301 TCB-UFH81BE AP0361-0481 RBC-UD281PE(W) AP0071-0121 RBC-UD501PE(W) AP0151-0181 RBC-UD801PE(W) AP0241-0301 RBC-UD1401PE(W) AP0361-0481 TCB-CA281BE AP0071-0121 TCB-CA501BE AP0151-0181 TCB-CA801BE AP0241-0301 TCB-CA1401BE AP0361-0481 TCB-FC281BE AP0071-0121 TCB-FC501BE AP0151-0181 TCB-FC801BE AP0241-0301 TCB-FC1401BE AP0361-0481 TCB-FK281BE AP0071-0121 TCB-FK501BE AP0151-0181 TCB-FK801BE AP0241-0301 TCB-FK1401BE AP0361-0481 TCB-UFM1D-1E AP0181/0481 AP0481 use two pcs. TCB-UFM2D-1E AP0241-0361 Use two pcs. TCB-UFH5D-1E AP0181/0481 AP0481 use two pcs. TCB-UFH6D-1E AP0241-0361 Use two pcs. TCB-PF1D-1E AP0181/0481 AP0481 use two pcs. TCB-PF2D-1E AP0241-0361 Use two pcs. TCB-FCY21DE AP0181 TCB-FCY31DE AP0241-0361 TCB-FCY51DE AP0481 Drain pump kit TCB-DP31DE AP0181-0481 Drain pump kit TCB-DP22CE2 AP0151-0481 TCB-KP12CE2 AP0151-0181 TCB-KP22CE2 AP0241-0481 Ceiling panel High Efficiency Filter 65 High Efficiency Filter 90 Long Life Pre-Filter Filter Chamber Optional AP0481 RBC-US21PGE TCB-UFM11BFCE Filter kit for underside Under Ceiling Type AP0151-0301 RBC-UW466PG TCB-FF101URE Filter Chamber Optional AP0071-0121 RBC-UW266PG TCB-BU21HWE Suction Canvas Concealed Duct High Static Pressure Type *** Auxiliary fresh air flange High Efficiency Filter 90 Optional Three-piece set RBC-UW136PG Front air discharge unit High Efficiency Filter 65 Concealed Duct Type Be used with TCB-GFC1601UE2 RBC-UM11PG(W)E Spacer for height adjustment Air Discharge Direction Kit Remarks Be used with TCB-GFC1601UE2 TCB-BC1601UE Air discharge direction kit Required accessory Ceiling panel Compact 4-way Air Discharge Cassette (600 x 600) Type Application model RBC-U21PG(W)-E2 Required accessory Ceiling panel Elbow piping kit 9-14 -2 For underside suction For underside suction (Half panel for underside suction) For underside suction For rear suction *Required accessories when using Drain Pump Kit PMV-Kit (RBM-PMV0361E/RBM-PMV0901E) shall be required for quiter place application as an optional to reduce refrigerant sound especially in oil retrieval control or in transient operation as start up. 10-1. Selection Model name RBM-PMV0361E Indoor unit capacity type 007,009,012 type 015,018 type 024 type RBM-PMV0901E Diameter of refrigerant pipe O / 6.4 O / 6.4 O / 9.5 Allowable length of refrigerant piping 2 m to 10 m NO GOOD OK PMV Kit PMV Kit Indoor unit PMV Kit Refrigerant pipe Indoor unit Indoor unit Note) Do not connect two or more indoor units to one PMV Kit. Arrange one indoor unit and one PMV Kit set to 1 by 1. • Connecting direction of refrigerant pipe When connecting pipes, be careful of direction of the main unit. Be sure to install the main unit so that [ ] mark in the label directs upward. For connection of the refrigerant pipes, follow the arrow mark in the label and connect pipes after confirming directions of indoor unit and outdoor unit. Label Piping material and dimensions Model name Indoor unit capacity type Diameter of refrigerant pipe RBM-PMV0361E 007, 009, 012 type Ø6.4 015, 018 type Ø6.4 RBM-PMV0901E Notes Attached joint 024 type Ø9.5 10 -1 Attached joint Fixation after connection pipes Set the hanging bolts for supporting pipes which are mounted at front and rear sides of PMV Kit at within 1m intervals. 1 m or less Hanging bolt Hanging bolt Refrigerant pipe PMV Kit 10 -2 10-2. W iring connections Wiring For this product , the connector co nve rsion ca ble (Accessory) is used according to the indoor unit to be connected . For the corresponding unit and how to use the conversio n cable, refer the following desc ription. Indoor unit which connector conversion ca ble is not used High Wall Type 2 se ries (MMK-AP0072H, MMK-AP0092H, MMK-AP0122H ) Connector conversion cable Connection cable Remove the connector conversio n cable which is attached to the connection cable (11m) out of the box. Indoor unit whi ch connector conve rsion ca ble is used Indoor unit excep t above indoor units Connection cable Connector conversion cable 10 .2006) 7.Apr.2006) -3 (Revised edition in 7.Apr 10-3. Dimension PMV Kit RBM-PMV0361E, RBM-PMV0901E Refrigerant pipe connecting port (Liquid pipe) Refrigerant pipe connecting port (Liquid pipe) 55 58 226 55 Connection cable (accessory) 30 26 500 or more Check port 450 x 450 55 55 200 or more RBM-PMV0901E (When attached joint are used)200 or more Installation image Binding band M Binding band L Binding band M Refrigerant pipe (Gas side) Heat insulating pipe Refrigerant pipe (Liquid side) 50 or more Binding band M 73 200 or more Heat insulating pipe 73 50 or more Binding band L Binding band M 50 or more Box cover RBM-PMV0361E,PMV0901E 50 or more 50 or more 161 76 76 36 30 200 or more Refrigerant pipe (Liquid side) Note: All dimensions are in mm. 10 -4 11-1. Specifications 50Hz Specifications (50Hz) Equivalent HP Equivalent to 4HP Equivalent to 5HP Equivalent to 6HP MMY- MCY-MAP0401HT2D MCY-MAP0501HT2D MCY-MAP0601HT2D Cooling capacity (*1) (kW) 12.1 14.0 15.5 Standard heating capacity (*1) (kW) 12.5 16.0 18.0 Model name Outdoor unit type Inverter unit Power supply (*2) 1 phase 60Hz 220V (A) 13.8 16.8 22.4 Power consumption (kW) 2.82 3.47 4.63 Power factor (%) 93 94 94 (kW/kW) 4.29 4.03 3.35 Running current Cooling EER (Energy Efficiency Ratio) Electrical characteristics (*1) Heating Starting current (A) Running current (A) 13.1 19.1 23.2 Power consumption (kW) 2.71 4.00 4.85 Power factor (%) 94 95 95 (kW/kW) 4.61 4.00 3.71 EER (Energy Efficiency Ratio) Starting current External dimension Soft start (A) Soft start (mm) Height 1,340/Width 900/Depth 320 117 (kg) Total weight Shilky shade (Munsell 1Y8.5/0.5) Color Compressor Hermetic Type Type (kW) Motor output 2.3 3.1 Propeller fan (Quantity 2) Fan Fan unit Motor output (kW) Air volume (m3 /h) 0.063 + 0.063 5,820 6,120 Finned tube Heat exchanger Refrigerant R410A (Charged refrigerant amount) (*3) High-pressure switch (kg) 7.2 (MPa) Open : 3.73 Close : 2.9 6,420 *5 Protective devices Connecting port dia Connecting method Gas side (mm) Liquid side (mm) 15.9 Discharge gas side Max. equivalent length Refrigerant piping Max. real length specifications (*4) Max. total pipe length (Real length) Flare (m) (m) 15 125 (If the total bend length exceeds 125m, use the max equivalent length as the standard.) (m) (m) Real length between PMV Kit and indoor unit (m) Outdoor unit is higher than indoor unit : 30 Outdoor unit is lower than indoor unit : 20 2-10 Control wiring Total wire length(indoor unit- indoor unit/ indoor unit-outdoor unit control wiring, central control wiring) Shield wire 1.25mm2 2cores, up to 1000m Shield wire 2.0mm2 2cores, up to 2000m 6 8 9 (dB(A)) 49/50 50/52 51/53 (dB(A)) 46/48 46/48 47/49 Max. No. of connected indoor units Night operation (Sound reduction)control*4 Brazing Flare Max. Height between indoor units Sound pressure level (Cooling/Heating) *3 19.1 9.5 Liquid side Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. The source voltage must not fluctuate more than ±10%. The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure switch, Over-current sensor, High-pressure sensor, Low pressure sensor, Over-current relay. *1 : Rated conditions *2 : *3 : *4 : *5 : 4.2 11 -1 60Hz Specifications (60Hz) Equivalent to 4HP Equivalent to 5HP Equivalent to 6HP MMY- MCY-MAP0401HT2D MCY-MAP0501HT2D MCY-MAP0601HT2D Cooling capacity (*1) (kW) 12.1 14.0 15.5 Standard heating capacity (*1) (kW) 12.5 16.0 18.0 Equivalent HP Model name Inverter unit Outdoor unit type 1 phase 60Hz 220V Power supply (*2) (A) 13.8 16.8 22.4 Power consumption (kW) 2.82 3.47 4.63 Power factor (%) 93 94 94 (kW/kW) 4.29 4.03 3.35 Running current Cooling EER (Energy Efficiency Ratio) Electrical characteristics (*1) Heating Starting current (A) Running current (A) 13.1 19.1 23.2 Power consumption (kW) 2.71 4.00 4.85 Power factor (%) 94 95 95 (kW/kW) 4.61 4.00 3.71 EER (Energy Efficiency Ratio) Starting current External dimension Soft start (A) Soft start (mm) Height 1,340/Width 900/Depth 320 117 (kg) Total weight Shilky shade (Munsell 1Y8.5/0.5) Color Compressor Hermetic Type Type (kW) Motor output 2.3 3.1 Propeller fan (Quantity 2) Fan Fan unit Motor output (kW) Air volume (m3 /h) 0.063 + 0.063 5,820 6,120 Finned tube Heat exchanger Refrigerant R410A (Charged refrigerant amount) (*3) High-pressure switch (kg) 7.2 (MPa) Open : 3.73 Close : 2.9 6,420 *5 Protective devices Connecting port dia Connecting method Gas side (mm) Liquid side (mm) 15.9 Flare Discharge gas side Max. equivalent length Refrigerant piping Max. real length specifications (*4) Max. total pipe length (Real length) (m) 15 (m) 125 (If the total bend length exceeds 125m, use the max equivalent length as the standard.) (m) (m) Real length between PMV Kit and indoor unit (m) Outdoor unit is higher than indoor unit : 30 Outdoor unit is lower than indoor unit : 20 2-10 Control wiring Total wire length(indoor unit- indoor unit/ indoor unit-outdoor unit control wiring, central control wiring) Shield wire 1.25mm2 2cores, up to 1000m Shield wire 2.0mm2 2cores, up to 2000m 6 8 9 (dB(A)) 49/50 50/52 51/53 (dB(A)) 46/48 46/48 47/49 Max. No. of connected indoor units Night operation (Sound reduction)control*4 Brazing Flare Max. Height between indoor units Sound pressure level (Cooling/Heating) *3 19.1 9.5 Liquid side Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. The source voltage must not fluctuate more than ±10%. The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure switch, Over-current sensor, High-pressure sensor, Low pressure sensor, Over-current relay. *1 : Rated conditions *2 : *3 : *4 : *5 : 4.2 11 -2 11-2. Dimension MCY-MAP0401HT, MCY-MAP0501HT, MCY-MAP0601HT, MCY-MAP0401HT2D, MCY-MAP0501HT2D, MCY-MAP0601HT2D in let Mounting bolt hole (O/ 12 x 17slot) A legs 43 Air outlet 40 54 21 60 108 600 150 Mounting bolt hole Details of A legs Details of B legs (O/ 12 x 17U-shape cut-out) 320 900 Refrigerant pipe connecting port (O/ 9.5 flare at liquid side) 89 25 722 718 625 1340 Refrigerant pipe connecting port (O/ 15.9 flare at gas side) 67 154 350 307 27 7 58 161 400 58 314 95 Knockout for lower piping 86 7 60 27 60 Z Z View Diameter of refrigerant pipe Name Control wiring and piping hole Power supply wiring hole Notes Knockout hole O / 38 Model name Gas side MCY-MAP0401HT* MCY-MAP0501HT* O / 15.9 (Flare) O / 15.9 (Flare) MCY-MAP0601HT* O / 19.1 Liquid side O / 9.5 (Flare) O / 9.5 (Flare) Blazing connection with attached joint socket. O / 9.5 (Flare) 365 150 or more Space required for service 2-O / 12 x 17U -shape cut-out (F or M 10 Anchor bolt) Air inlet 150 or more Mnimum distance up to wall Air outlet 500 or more 46 300 or more 2-O / 12 x 17 slot (F or M 10 Anchor bolt) 80 600 60 165 17.5 26 12 40 Knockout(Drain) 17.5 40 43 Air let i in 40 40 365 Drain hole(O/ 20x88) 191 20 Drain hole(O/ 25) Air B lege 90 21 29 70 17.5 Knockout(Drain) 32 45 Note: All dimensions are in mm. 11 -3 11-3. Units center of gravity Model name 1340 900 320 Weight (kg) Main unit 117 610 MCY-AP0401HT MCY-AP0401HT2D MCY-AP0501HT MCY-AP0501HT2D MCY-AP0601HT MCY-AP0601HT2D H (mm) W (mm) D (mm) 440 150 200 600 365 11 -4 11-4. Wiring diagram 11 -5 11 -6 11-5. Part Load Performance MCY-MAP0401HT* Cooling Compressor + Outdoor fan motor Power consumption (kW) Outdoor Temperature DB˚C 40 35 30 25 20 15 Outdoor unit 100% 100% 90% 80% 70% Cooling Load Load Load Load Capacity (kW) 11.5 3.07 2.58 2.14 1.76 12.1 2.37 1.97 1.62 2.82 12.1 2.39 2.01 1.68 1.39 12.1 2.03 1.72 1.44 1.20 12.1 1.81 1.53 1.29 1.07 12.1 1.64 1.39 1.17 0.98 Indoor air temperature conditions : 27 ˚CDB, 19˚CWB Indoor unit fan speed : High 60% Load 50% Load 1.43 1.31 1.14 0.99 0.89 0.81 1.16 1.06 0.93 0.82 0.74 0.68 Heating Outdoor Temparature DB˚C WB˚C 15 13.7 11 9.8 7 6 1 0.3 -5 -5.6 -10 -10.5 Compressor + Outdoor fan motor Power consumption (kW) Outdoor unit 100% 100% 90% 80% 70% 60% 50% Heating Load Load Load Load Load Load Capacity (kW) 12.5 2.38 2.02 1.69 1.38 1.11 0.86 12.5 2.53 2.14 1.79 1.46 1.17 0.90 12.5 2.29 1.91 1.56 1.24 0.96 2.71 11.2 2.59 2.19 1.82 1.49 1.18 0.91 9.9 2.46 2.08 1.73 1.41 1.13 0.87 8.7 2.35 1.99 1.66 1.35 1.08 0.83 Indoor air temperature conditions : 20 ˚CDB Indoor unit fan speed : High 11 -7 MCY-MAP0501HT* Cooling Compressor + Outdoor fan motor Power consumption (kW) Outdoor unit Outdoor 100% 100% 90% 80% 70% 60% 50% Temperature Cooling Load Load Load Load Load Load Capacity DB˚C (kW) 40 13.3 3.78 3.10 2.52 2.03 1.63 1.34 3.47 35 14.0 2.80 2.28 1.85 1.50 1.19 30 14.0 2.90 2.39 1.95 1.59 1.30 1.08 25 14.0 2.45 2.03 1.67 1.37 1.13 0.96 20 14.0 2.17 1.80 1.48 1.22 1.02 0.87 15 14.0 1.96 1.63 1.35 1.12 0.93 0.80 Indoor air temperature conditions : 27 ˚CDB, 19˚CWB Indoor unit fan speed : High Heating Outdoor Temparature DB˚C WB˚C 15 13.7 11 9.8 7 6 1 0.3 -5 -5.6 -10 -10.5 Compressor + Outdoor fan motor Power consumption (kW) Outdoor unit 100% 70% 60% 50% 100% 90% 80% Heating Load Load Load Load Load Load Capacity (kW) 16.0 3.46 2.98 2.49 2.04 1.64 1.27 16.0 3.71 3.16 2.64 2.16 1.72 1.33 4.00 16.0 3.39 2.82 2.30 1.83 1.41 14.4 3.82 3.23 2.69 2.20 1.75 1.35 12.6 3.63 3.07 2.56 2.09 1.66 1.28 11.1 3.47 2.94 2.45 2.00 1.59 1.23 Indoor air temperature conditions : 20 ˚CDB Indoor unit fan speed : High 11 -8 MCY-MAP0601HT* Cooling Compressor + Outdoor fan motor Power consumption (kW) Outdoor unit Outdoor 100% 100% 90% 80% 70% 60% 50% Temperature Cooling Load Load Load Load Load Load Capacity DB˚C (kW) 40 14.7 5.05 4.14 3.36 2.70 2.18 1.78 4.63 35 15.5 3.74 3.04 2.47 2.01 1.59 30 15.5 3.71 3.19 2.61 2.12 1.73 1.44 25 15.5 3.03 2.71 2.22 1.83 1.51 1.27 20 15.5 2.64 2.40 1.98 1.63 1.36 1.16 15 15.5 2.37 2.17 1.80 1.49 1.24 1.06 Indoor air temperature conditions : 27 ˚CDB, 19˚CWB Indoor unit fan speed : High Heating Outdoor Temparature DB˚C WB˚C 15 13.7 11 9.8 7 6 1 0.3 -5 -5.6 -10 -10.5 Compressor + Outdoor fan motor Power consumption (kW) Outdoor unit 100% 70% 60% 50% 100% 90% 80% Heating Load Load Load Load Load Load Capacity (kW) 18.0 4.21 3.53 2.90 2.33 1.81 1.35 18.0 4.50 3.77 3.10 2.49 1.93 1.44 4.85 18.0 4.06 3.34 2.67 2.08 1.54 16.2 4.63 3.88 3.18 2.55 1.98 1.47 14.2 4.40 3.68 3.03 2.43 1.88 1.40 12.5 4.21 3.52 2.89 2.32 1.80 1.34 Indoor air temperature conditions : 20 ˚CDB Indoor unit fan speed : High 11 -9 11-6. Sound Characteristics (NC Curve) MCY-MAP0401HT MCY-MAP0501HT Mode Cooling Heating Mode Cooling Heating Sound pressure level (dB(A)) 49 50 Sound pressure level (dB(A)) 50 52 90 90 Cooling 70 NC- 60 NC- 50 NC- 40 NC- 30 20 NC- Approximate threshold of hearing for continuous noise Cooling 80 Heating NC- 10 Octave band sound pressure level (dB) Octave band sound pressure level (dB) 80 Heating 70 NC- 60 NC- 50 NC- 40 NC- 30 20 NC- NC- Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 Octave band center frequency (Hz) 8000 63 125 250 500 1000 2000 4000 Octave band center frequency (Hz) 8000 MCY-MAP0601HT Mode Cooling Heating Sound pressure level (dB(A)) 51 53 90 Cooling Octave band sound pressure level (dB) 80 Heating 70 NC- 60 NC- 50 NC- 40 NC- 30 20 NC- NC- Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 Octave band center frequency (Hz) 8000 [Measuring location] [Conditions] Center 1m Cooling Outdoor temperature: 35˚CDB, 24˚CWB Indoor air temperature: 27 ˚CDB, 19˚CW B Microphone Heating Outdoor temperature: 7˚CDB, 6˚CWB Indoor air temperature: 20 ˚CDB 1.5m Air outlet Air inlet This sound pressure level are measured in an anechoic chamber in accordance. 11 -10 [Night operation (sound reduction) control ] MCY-MAP0601HT MCY-MAP0401HT,MCY-MAP0501HT Mode Cooling Heating Mode Cooling Heating Sound pressure level (dB(A)) 46 48 Sound pressure level (dB(A)) 47 49 90 90 Cooling 80 Heating NC- 60 NC- 50 NC- 40 NC- 30 NC- 20 Octave band sound pressure level (dB) Octave band sound pressure level (dB) 70 Cooling 80 Heating 70 NC- 60 NC- 50 NC- 40 NC- 30 NC- 20 Approximate threshold of hearing for continuous noise NC- 10 NC- Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 Octave band center frequency (Hz) 8000 [Measuring location] 63 125 250 500 1000 2000 4000 Octave band center frequency (Hz) 8000 [Conditions] Center 1m Cooling Outdoor temperature: 25˚CDB, 16˚CWB Indoor air temperature: 27 ˚CDB, 19˚CWB Microphone Heating Outdoor temperature: 7˚CDB, 6˚CWB Indoor air temperature: 20 ˚CDB 1.5m Air outlet Air inlet This sound pressure level are measured in an anechoic chamber in accordance. 11 -11 11-7. Accesories 11-7-1. Branching joints and headers Branch header RBM-HY1043E, HY1083E A Gas side 80 x n O /E 50 O /D C B Insulator O /E A Liquid side 80 x n B O /D O /D 61 B Insulator Model Gas side A B 380 90 ØE n 83.6 22.2 15.9 3 C ØD Accessory socket x Q’ty 6 x 4, 9 x 4, 14 x 1, 18 x 1, 70 x 1 RBM-HY1043E Liquid side 360 60 700 90 Gas side 74.5 _ 15.9 9.5 3 83.6 22.2 15.9 7 RBM-HY1083E Liquid side 680 60 _ 15.9 9.5 7 1 x 4, 6 x 1, 9 x 1 6 x 8, 9 x 8, 14 x 1, 18 x 1 70 x 1 1 x 8, 6 x 1, 9 x 1 Note: All dimensions are in mm. 11 -12 Y-shape branch joint RBM-BY53E, BY103E O /B O /D O /C O /D Gas side Insulator A O /D B O /C O /D Liquid side Insulator A Model A B ØC 250 80 15.9 12.7 5 x 2, 54 x 2, 9 x 1, Liquid side 200 70 12.7 9.5 1 x 2, 5 x 1 350 80 22.2 19.1 7 x 1, 10 x 1, 13 x 2, 52 x 2, 70 x 1, 89 x 1 2 x 1, 5 x 2, 6 x 1, Gas side ØD Accessory socket x Q’ty 51 x 1 RBM-BY53E Gas side RBM-BY103E Liquid side 250 80 15.9 12.7 18 x 1, 9 x 1, 54 x 1 Note: All dimensions are in mm. 11 -13 11-7-2. Application controls of outdoor unit Note : The P.C. boards of outdoor unit (TCB-PCDM2E, TCB-PCMO2E, TCB-PCIN2E) can be installed up to two boards. Model Name Appearance Function [1] Power peak-cut Control Normal current Outdoor unit capacity type MCY- 0401 type 0501 type 25A 28A Normal current (Maxim running current) 0601 type 31A Feature The upper limit capacity and current of the outdoor unit is restricted based on the demand request signal from outside. Wiring Size : 71 x 85 Input wiring Output wiring Application Len gth Up to 500m Up to 200m Up to 400m Size 2-core or 3-core, 0.75mm2 2-core, 0.75mm2 * 2-core, 1.5mm2 * Type Shield wire Shield wire * In conformity with design 60245 IEC 57 Function / Electric wiring diagram Two type control can be selected by setting SW07 on the interface P.C. board of the outdoor unit. [Standard funciton] TCB-PCDM2E Outdoor unit Local Supply TCB-PCDM2E I/F P.C Boad Display Relay SW07 Bit2 OFF Connection Cable L1 OPERATION Power Supply L1 COM ON PJ17 CN513 :Display lamp suring power peak-cut control. *Install this optional P.C. board in the inverter assembly of the outdoor unit. SW1 ON SW2 COM OFF SW1 SW2 OFF Shield wire In case of pulse signal Be sure to prepare the point of contact for each terminal. The time of the pulse signal is more than 100msec. Don't switch on both SW1 and SW2 terminal simultaneously. SW07-Bit2 OFF Input SW1 OFF SW2 ON ON OFF SW07-Bit1 OFF Capacity Current SW07-Bit1 ON Capacity Current 100% (Nomal) 100% (Nomal) 100% (Normal) 100% (Normal) OFF 0% (stop) 0% (stop) Up to 60% Up to 80% ON Display Relay (L1) ! CAUTION) Be sure to prepare a non-voltege point for each terminal. Display Relay capacity of "OPERATION" Below AC240V 0.5A (COS =100%) When connecting load such as relay coil to "L1" load, insert the noise surge absorber. Below DC24V 1A (Non-indutive load) When connecting load such as relay coil to "L1" load, insert the bypass circuit. 11 -14 Model Name Appearance Function [Expansion function] Local Supply Outdoor unit TCB-PCDM2E I/F P.C Boad Display Relay SW07 Bit2 ON OPERATIO Connection Cable PJ17 CN513 Power Supply L1 COM ON SW1 ON COM OFF SW2 OFF Size : 71 x 85 Shield wire L1 :Display lamp suring power peak-cut control. Application SW07-Bit2 ON TCB-PCDM2E Input SW07-Bit1 OFF Capacity Current SW07-Bit1 ON Capacity Current 100% (Nomal) 100% (Normal) Display Relay (L1) SW1 OFF SW2 OFF ON OFF Up to 80% Up to 80% Up to 85% Up to 90% ON OFF ON ON ON ON ON 100% (Nomal) 100% (Normal) Up to 60% Up to 70% Up to 75% Up to 80% 0% (stop) 0% (stop) Up to 60% Up to 70% OFF ! CAUTION) *Install this optional P.C. board in the inverter assembly of the outdoor unit. Be sure to prepare non voltage continuous point of contact for each terminal. Display Relay capacity of "OPERATION" Below AC240V 0.5A (COS =100%) When connecting load such as relay coil to "L1" load, insert the noise surge absorber. Below DC24V 1A (Non-indutive load) When connecting load such as relay coil to "L1" load, insert the bypass circuit. 11 -15 Model Name Appearance Function [2] Snowfall fan control Feature Outdoor fan is operated by the snowfall signal from outside. Function Local Supply TCB-PCMO2E COM SMC TCB-PCMO2E Size : 55.5 x 60 Cooling Application SMC : Cooling mode select input (switch) Terminal Input signal Operation ON Snowfall fan control (Operates outdoor fan.) SMC OFF ON Usual operation OFF This control is activated when a input signal increases or decreases. (The increasing or decreasing signal needs to be held for a minimum of 100m/sec in order to activate the control) [3] External master ON/OFF control Feature The outdoor unit starts or stops the system. Function Local Supply TCB-PCMO2E COM SMC Cooling Heating SMH SMC : Input signal for start SMH : Input signal for stop Terminal *Install this optional P.C. board in the inverter assembly of the outdoor unit. Input signal Operation ON Starts all indoor units. SMC OFF ON SMH Stops all indoor units. OFF Ensure terminal contacts are securely fixed. This control is activated when the input signal increases or decreases (The increasing or decreasing signal needs to be held for a minimum of 100m/sec in order to activate the control.) 11 -16 Model Name Appearance Function [4] Night operation (Sound reduction) control Feature Sound level can be reduced by restricting the compressor and fan speeds. Function Local Supply TCB-PCMO2E COM TCB-PCMO2E Size : 55.5 x 60 SMC Cooling Application SMC : Cooling mode designated input switch Terminal Input signal Operation ON Night operation control OFF ON SMC Usual Operation OFF This control is activated when the input signal increases or decreases. (The increasing or decreasing signal needs to be held for a minimum of 100m/sec in order to activate the control). [5] Operation mode selection control Feature This control can restrict the selectable operation mode. Function *Install this optional P.C. board in the inverter assembly of the outdoor unit. Local Supply TCB-PCMO1E COM SMC Cooling Heating SMH SMC : Cooling mode designated input switch SMH : Heating mode designated input switch SMC SMH ON OFF OFF ON Selected operation mode Only cooling mode permitted Only heating mode permitted Ensure terminal contacts are securely fixed. 11 -17 Model Name Appearance Function [6] Error / Operation output control * I/F P.C. Board TCB-PCIN2E Display Relay OPERATION TCB-PCIN2E CN511 Power Supply L1 Connection Cable Size : 73.0 x 79 Local Supply PJ20 Display Relay Application EMG Power Supply L2 L1 : Operation monitoring lamp L2 : Error monitoring lamp *Install this optional P.C. board in to the inverter assembly of the header outdoor unit. Ensure terminal contacts are securely fixed. Display Relay capacity of "OPERATION" and "EMG" Below AC240V 0.5A(COSφ=100%) When connecting a load such as a relay coil to "L1,L2", insert the noise surge absorber. Below DC24V 1A(Non-inductive load) When connecting a load such as a relay coil to "L1,L2", insert the byass circuit. 11 -18 Dimension TCB-PCDM2E 71 Terminal Screw M3 x 6 4-4O / hole 75 85 61 Terminal Screw M4 x 8 TCB-PCMO2E 55.5 4-4O/ hole 45.5 50 60 Terminal Screw M3 x 6 TCB-PCIN2E 63 73 79 69 Terminal (Screw M3 ) 11 -19 4- 4 hole 12 -1 Error/operation output I/F Local supply LONWORKS Error output control board TCB-PCIN2E External master ON/OFF board TCB-PCDMO2E Power peak-cut control board TCB-PCDM2E LON Gateway Central remote controller TCB-SC642TLE2 ON/OFF Command Alarm Status output Weekly timer RBC-EXW21E2 Master ON/OFF signal Batch drive, error output Power Meter Energy Monitoring relay Interface BMS-IFWH3E TCS-Net Interface BMS-IFLSV1E 1 BACnetTM : ANSl/ASHRAE135Ð1995, A Data CommuniCation Protocol for Bulding Automation and ControI Networks. 2 LoNWoRKS¨, Resisterd trademark of Echelon Corporation Power peak-cut control signal BMS-LSV4E Intelligent server Air-conditioning Management System on site Master ON/OFF signal Monitoring Remote control Schedule operation Error code indication Alarm list indication Monthly report Energy monitoring data etc. Touch screen controller Side remote controller Mini-SMMS Master remote controller Weekly timer RBC-EXW21E2 Remote location ON/OFF control board TCB IPCB-4E "1:1model" connection interface TCB-PCNT30TLE2 Wired remote controller RBC-AMT31E Simple remote controller Wireless remote RBC-AS21E2 controller Super Modular Multi Outdoor Unit Super Digital Inverter Digital Inverter Outline of application Control 12-1. Applications 12-1-1. Applications for indoor remote controller Basic function System diagram Model Wired remote controller RBC-AMT31E Main remote controller Simple remote controller RBC-AS21E2 Indoor unit Possible up to Max. total length 500m Remote controller 1-1 Wireless remote controller kit TCB-AX21U(W)-E2 RBC-AX22CE2 TCB-AX21E2 Individual control Air conditioner is individually operated at a distance. Wireless remote controller Indoor unit ((( Receiver unit Wireless Remote controller Wired remote controller RBC-AMT31E Max.8 indoor units Simple remote controller RBC-AS21E2 GROUP control 1-2 One remote controller can control a group of up to a maximum. 8 indoor units.Operating on the same setting Indoor unit Indoor unit Indoor unit Remote controller Possible up to Max.total length 500m 12 -2 Indoor unit Basic function System diagram Model Wired remote controller RBC-AMT31E Wired system Simple remote controller RBC-AS21E2 Indoor unit Remote controller Remote controller Master Side Wireless remote controller kit TCB-AX21U(W)-E2 RBC-AX22CE2 TCB-AX21E2 Possible up to Max. total length 500m Two remote control 1-3 Wireless system Air conditioner is controlled by two remote controllers in two locations. Indoor unit (( ((( ( Wireless remote controller 1 Wireless remote controller 2 Master Side Indoor unit (( ( Wired & Wireless combination control (Either one of the two controllers can be set as side control). Remote controller Wireless remote controller Weekly timer function Setting of ON-OFF 3 times par day Timer operation time is displayed. Holiday period 1-4 Control by weekly timer + Weekly timer RBC-EXW21E2 Indoor unit Weekly schedule operation Remote controller Wired remote controller RBC-AMT31E Weekly timer 12 -3 12-1-2. Application controls for central remote controller Basic function System diagram Model Central remote controller TCB-SC642TLE2 Mini-SMMS Outdoor unit Line-3 Indoor unit U3, U4 Indoor remote controller Wired remote controller RBC-AMT31E U1, U2 Zone 4 Indoor remote controller U3, U4 U5, U6 Outdoor unit Super MMS Line-2 Indoor unit Simple remote controller RBC-AS21E2 U1, U2 Zone 3 Zone 2 Indoor remote controller Outdoor unit U3, U4 Mini-SMMS Indoor unit Line-1 2-1 Central management controller for 64 units U1, U2 Zone 1 PMV Kit Indoor remote controller Power Central supply remote controller Single phase 220/230/240V Function of central remote controller Individual control for up to 64 indoor units. Individual control for max. 64 indoor units divided in to 4 zones. (Up to 16 indoor units for each zone.) Up to 16 outdoor header units are connectable. 4 specific central control settings to restrict individual operation by remote controller are selectable. Different settings for one of 1 to 4 zones. Usable with other central control devices (Up to 10 central control devices in one control circuit) Two selectable control modes Central controller mode/Remote controller mode Setting of simultaneous ON/OFF 3 times per day when a controller is combined with using a weekly timer. U3, U4 2-2 Central remote controller + Weekly timer Weekly operation schedule can be set by connecting a weekly timer to the central remote controller Central remote controller TCB-SC642TLE2 Outdoor unit Indoor unit U1, U2 + Weekly timer RBC-EXW21E2 PMV Kit Indoor remote controller Indoor remote controller Single phase 220/230/240V Power supply Weekly timer Central remote controller 12 -4 Wired remote controller RBC-AMT31E or Simple remote controller RBC-AS21E2 Basic function System diagram Model Central remote controller TCB-SC642TLE2 Indoor remote controller Wired remote controller RBC-AMT31E U3, U4 Outdoor unit U1, U2 Power supply Indoor unit PMV Kit Central remote controller Single phase 220/230/240V Even when grouping operation is performed by connecting multiple indoor units to 1 line, the indoor remote controller is required. 2-3 Central remote controller without indoor remote controller Example of grouping operation U3, U4 Power supply Outdoor unit U1, U2 (Group) Indoor remote controller is required Central remote controller PMV Kit Available Single phase 220/230/240V U3, U4 Outdoor unit U1, U2 Power supply PMV Kit (Group) Available Central remote controller Single phase 220/230/240V 12 -5 Basic function System diagram Model Central remote controller TCB-SC642TLE2 TCB-SC163TLE2 "1 : 1 model" connection interface TCB-PCNT30TLE2 RAV-SM560KRT-E, SM800KRT-E are not compatible to connect Indoor remote controller Wired remote controller RBC-AMT31E Power supply Central remote controller Simple remote controller RBC-AS21E2 U3, U4 2-4 Central management control with "1 : 1 model" Outdoor unit *1 U1, U2 PMV Kit Indoor unit Indoor remote controller "1:1 model" connection interface * TOSHIBA Digital Inverter System and Super Digital Inverter System 12 -6 12-1-3. Application control for network Basic function System diagram Model LN interface TCB-IFLN640TLE "1 : 1 model" connection interface TCB-PCNT30TLE2 RAV-SM560KRT-E, SM800KRT-E are not compatible to connect Indoor remote controller Wired remote controller RBC-AMT31E or Simple remote controller RBC-AS21E2 LON Center LON WORKS LN Interface TCB- 3-1 LONWORKS (*1) R Outdoor unit *1 PMV Kit Remote controller "1:1 model" connection interface *1 TOSHIBA Digital Inverter System and Super Digital Inverter System The LONWORKS interface should be connected between a building management computer and a Mini-SMMS / Super HRM / Super MMS system. Max. 64 indoor units are connectable per interface. *1) LONWORKS : Registerd trademark Echelon corporation. 12 -7 Basic function System diagram Model BACnet server BMS-LSV4E BACnet server software XXX-XXXXXX TCS-Net Relay Interface BMS-IFLSV1E "1 model" connection interface TCB-PCNT30TLE2 RAV-SM560KRT-E, SM800KRT-E are not compatible to connect. BAC net center BAC net server TCB- Indoor remote controller Wired remote controller RBC-AMT31E TCN-NET relay interface Outdoor unit *1 Simple remote controller RBC-AS21E2 PMV Kit Remote controller 3-2 "1:1 model" connection interface BACnet R (*1) TOSHIBA Digital Inverter System and Super Digital Inverter System The local server should be connected to the BACnet network and the Mini-SMMS and Super MMS Super HRM system will be connected through the interface. *1) BACnetTM: ANSI/ASHRAE 135-1995, A Data Communication Protocol for Building Automation and Control Networks. 12 -8 12-1-4. Touch screen controller system System diagram Setup file (record in CF card) Touch Screen Controller Intelligent Server Intelligent Server Software Max. 64 indoor units Max. 16 Refrigerant systems per TCSNET relay interface Ethernet connection RS-485 TCS-Net Relay Interface Switching HUB (Local Supply) Control Maximum 512 indoor units Control wiring Control wiring Maximum 4 Intelligent server PC for Energy Monitoring (Local supply) RS-485 Control wiring Report Creation software (Excel macro) Maximum 8 TCS-NET Relay Interface RS-485 (Note) Switching HUB (10BASE-T compliant) is required when using two or more intelligent servers or when connecting a PC for energy monitoring and billing. Maximum 4 Energy Monitoring Relay Interface Energy Meter Relay Interface 1kWh/pulse or 10kWh/pulse 50-1000ms Maximum 8 digital inputs I/F Maximum 4 digital outputs Digital I/O Relay Interface Function Devices Model Name Touch Screen controller (English version) Intelligent Server Intelligent Server Software TCS-Net Relay Interface Energy Monitoring Relay Interface Digital I/O Relay Interface (1) Monitoring air-conditioners Model Name BMS-TP0640ACE BMS-TP5120ACE BMS-TP0640PWE BMS-TP5120PWE BMS-LSV4E BMS-STCC01E BMS-IFLSV1E BMS-IFWH3E BMS-IFDD01E Max. 32 (8 X 4) power meter per intelligent server Maximum 8 Power Meter Maximum 4 Digital I/O Relay Interface 3-3 Fire alarm Door Key Entry ON/OFF Error code output Local supply Pulse Signal I/F RS-485 [ Power meter ] Max. 32 (8 X 4) digital inputs Max. 16 (4 X 4) digital outputs per intelligent server Specification Max 64 indoor units , without energy monitoring and billing Max 512 indoor units , without energy monitoring and billing Max 64 indoor units , with energy monitoring and billing Max 512 indoor units , with energy monitoring and billing Server in between Touch Screen controller and RS-485 Installed on Intelligent Server Interface between intelligent Server Control wiring(TCC-LINK) Interface for power meter Interface for input / output signal Operation status can be viewed according to a unit. [Unit] All building, All tenants, Each tenant, Each area, Each remote controller group [Monitoring contents] Operation and alarm status, Setting status for each remote controller group (2) Operating of air-conditioners Header / individual control can be performed according to a unit. [Operating contents] ON/OFF, Operation setting (operation mode, air volume, louver position, setting temp., restricted setting from remote location) (3) Schedule operation Air-conditioners are operated according to the set-up schedule / operation pattern. Schedule opretaion can be performed according to a unit. [Operation pattern] Weekly pattern, special day pattern (4 pattern), Non-operation days pattern (4) Alarm list display The present alarm contents are displayed. [Display contents] Alarm contents, Unit number, Generated time (5) Alarm record display The alarm history records are displayed. [Display contents] Alarm contents, Unit number, Generated time (6) Monthly report data extraction Monthly report data is written to "Compact Flash". Monthly reports can be created according to a unit using the monthly report software. [Monthly report contents] The number of ON/OFF, Operating time, Results of energy monitoring (7) Energy monitoring data extraction Power consumption data is written to "Compact Flash". Energy monitoring can be performed according to a unit using the energy monitoring software. [Energy monitoring data] Power consumption according to the power meter 12 -9 12-2. Controller dimensions Wired remote controller RBC-AMT31E 120 120 84 18 62 16 Note : All dimensions are in mm Simple remote controller 120 80 RBC-AS21E2 13 60 70 16 Note : All dimensions are in mm 12 -10 Wireless remote controller kit TCB-AX21U (W)-E2 186 19.5 177 186 58 32 61 Note : All dimensions are in mm RBC-AX22CE2 130 19.5 177 65 58 61 Note : All dimensions are in mm 12 -11 Wireless remote controller kit TCB-AX21E2 58 19.5 83.5 177 83.5 4.4 x 9.4 long hole 13 70 4.4 x 5.4 long hole 61 Note : All dimensions are in mm Weekly timer RBC-EXW21E2 120 2.7 4 16 120 Note : All dimensions are in mm 12 -12 ON-OFF controller 116 TCB-CC163TLE2 Unit: mm 160 (6) 148 14 69 115 121 148 (6) 160 6 6 Z 122 4-Ø5 diameter holes (for mounting) 128 Hole for electrical wiring 47 80 128 36 13 80 4-Ø5.5 diameter holes (for mounting) Z-view (back side) 12 -13 Note : All dimensions are in mm Remote sensor 80 120 TCB-TC21LE2 13 60 70 16 Note : All dimensions are in mm Central remote controller TCB-SC642TLE2 160 148 21 69 Z 115 (6) 121 6 148 (6) 160 6 13 15 116 47 121 47 80 128 36 13 128 80 Z view (back side) 12 -14 Note : All dimensions are in mm TCS-Net relay interface BMS-IFLSV1E 200 6- 5.5 mounting holes 78 22 22 78 78 22 66 63.6 156 170 78 146.9 22 Note : All dimensions are in mm Touch screen controller BMS-TP0640ACE BMS-TP5120ACE BMS-TP0640PWE BMS-TP5120PWE 256 91.75 70 99.3 75 242 95.75 75 302 55.5 19 30 82.5 48 16 5 316 249 54 49 Note : All dimensions are in mm 12 -15 Intelligent server 39 CAUTION Do not remove. 198 BMS-LSV2E 370 WARNING Do not decompose. Note : All dimensions are in mm Energy monitoring relay interface/Digital I/O relay interface BMS-IFWH3E BMS-IFDD01E 18 18 234 Grommet for power input 92.5 (193) 103.5 Grommet for power meter 18 18 53.5 64.5 Grommet for RS-485 63.6 220 246 Note : All dimensions are in mm 12 -16 LON GATEWAY TCB-IFLN640TLE Mounting hole 6-O / 5.5 18 18 78.5 78.5 193 78.5 78.5 18 18 234 66 63.6 220 246 Note : All dimensions are in mm 12 -17