Download Bosch PIF6..T1.. Specifications
Transcript
ECODRIVE Drive Controller DKC02.1 F245 External Encoder Failure: Quadrant Error A hardware fault has been detected in the external measuring system’s high-resolution position interface for sinusoidal signals. Cause: 1. 2. 3. Defective encoder cable Interference on encoder cable Defective amplifier Remedial action: Ref. 1. Replace the encoder cable Ref. 2. Lay the encoder cable separately from power cables Ref. 3. Replace the amplifier F248 Low Battery Voltage Cause: In a motor of the MKD series, the absolute position information is stored in a battery-backed electronics system in the motor feedback. The battery has been designed for a utilization period of 10 years. This message is output if the battery voltage drops below 2.8 V. The function of the absolute encoder is ensured for another two weeks. CAUTION Hazard: Faults in controlling motors and/or moved elements may lead to injuries. ⇒ Action: Replace battery as soon as possible Preparation for changing batteries The following parts are required: • Size 10 TORX screwdriver • Flat nose pliers; torque wrench • New pre-assembled battery (order no.: 257101) CAUTION Hazard: Faults in controlling motors and/or moved elements may lead to injuries. ⇒ Switch off the power supply and secure it against being switched on again. Replace the battery while the control voltage is switched on. If the control voltage were switched off while the battery is disconnected, the right reference point would be lost and must be re-established. DOK-ECODRV-SSE-03VRS**-WAR1-EN-P • 12.96 Error Diagnostic Messages 2-7