EMC-6 EMC-6L Select Status Inputs for Fan Monitoring The EMC-6 has 12 discrete Fan Diagnostic Inputs (DG). Each Diagnostic Input should only be assigned to one fan bank. Turn the buttons to ON if DG inputs are connected to this fan bank. Ensure all the others are OFF. Reset locked fan error – check to enable it. When enabled, the controller will set the fan bank PWM % to 0 to restart the failed fans after the fans give up restarting by themselves. The period for resetting the fans is set on Global Settings. On the same page GUI also displays the real time demand and status of all the stimuli. Send New Settings - loads the new settings into the unit’s RAM memory and activates these stimuli. Permanently save settings 021-00360 Rev A.2 32 Copyright © High Country Tek, Inc. – 2014