Download Foreword

Transcript
WIN-9_F Series User Manual
180
60 sec
Short time
Blowercooled
Load (%)
150
Effective when operated
at low speeds (approx.
6Hz).
Standard
Rating
100
Effective when operated at low speeds
(approx. 6Hz).
55
38
0
6
60
120
Frequency (Hz)
Base Frequency 60Hz
(V/f for 60Hz, 230V Input Voltage)
Use blower-cooled motor for continuous operation at low speeds.
5.2.16 Multi-Step Speed Selection
This function allows the programming of up to 4 preset speeds, through multifunction contact input function selections.
4-step speed selection
P002 = “1” (operation mode selection)
P025 = 30.0Hz (factory default)
P026 = 40.0Hz (factory default)
P027 = 50.0Hz (factory default)
P028 = 60.0Hz (factory default)
P038 = 9 (multi-function contact input terminal S5)
P039 = 10 (multi-function contact input terminal S6)
●
48
●