Download SECTION 3 USING THE KEYPAD/DISPLAY - Sea

Transcript
SECTION 3
USING THE KEYPAD/DISPLAY
________________________________________________________
3.6 CHANGE OVER USING AN EXISTING LABEL IN THE
HSM-DUCTOR
When a label is to be run again, perform following to set-up the label
at change over.
1) Select the respective label number on the Keypad/Display.
2) Set the keys open (predefined number of turns, a number which is
used for all ink stations on all labels) on the areas of the can that
will have ink and closed on areas that will not have ink.
3) Run the machine and verify that ink is being distributed on the can
correctly. The ink will be metered at the same rate as previously
set the last time the label was run. Thus only minor adjustments
to the keys may be necessary to assure that ink is not distributed
to areas where no color is applied (resulting in slinging due to ink
build up).
________________________________________________________
3.7 VIEWING THE TOTAL NUMBER OF CYCLES FOR EACH
DUCTOR
The total number of cycles for each ductor is accumulated in the
M4503. This is used for life expectancy and predictive maintenance
purposes to determine when air cylinders or solenoids should be
replaced. To view the number of cycles for each ductor, perform the
following:
1) Press the <DISPLAY DATA> key. The total number of cycles
for ductors 1 and 2 will be displayed.
2) To view the counts for ductors 3 and 4, press <NEXT> key. The
counts for ductors 3 and 4 will be displayed.
3) Continue pressing the <NEXT> key to view the counts for the
remaining ductors.
HSM-DUCTOR User’s Manual
SYSTEMS Electronics Group
- 24 -