Download DUAL PUMP STARTER PANEL
Transcript
USER MANUAL PROTON POWER CONTROL PVT. LTD., PUNE DUAL PUMP STARTER PANEL Product Code: PSP 33M WORKING: In normal running mode, display shows 1. r-HP--R phase Current 2. y-HP--Y phase Current 3. b-HP--B phase Current 4. r-Rp--R phase Current 5. y-rP--Y phase Current 6. b-rP--B phase Current 7. < Faults if any> • oL HP--Over load HP • Ub HP--Unbalance HP • oL rP-- Over load rP • Ub rP-- Unbalance rP • SP HP--Single phase HP • SP rP--Single phase rP All the protections like Overload, current unbalance are activated in Auto as well as manual mode. Auto/ Manual selection is done from front switch. In any mode, if the faults are present controller immediately turns off the motor having the fault. The motors can be restarted by resetting the fault by pressing the ‘Decrement’ key. In manual mode there are two separate switches, one for each motor to turn on and off. If the supply is within the range and there is no fault condition, an ON timer starts decrementing to zero and motor relay is turned ON. This relay interlocks with the Pump On signal. After the Pump motor is switched on, if any unhealthy condition occurs, fault LED start blinking up to trip delay time and then the is Relay is turned OFF. Fault LED continuously glows if the faulty condition persists. Features: • Three digits 7 segment bright display for current. • Calibration: using front keys. • User Programmable. • Password protected set parameters. • Inbuilt 3 Phase 10 A Contactor for load control. • Message Display for faults. The Starter Panel has is solid state Current Meters. It measures currents and provides protection against overload for both the motors. This is based on a Microchip, programmed for the application. The Meter’s supplied preprogrammed for operation and can be directly installed. Specifications: Nominal Input Current: - 0-9 A per Phase. Accuracy: Current: - 0.25% ± 1 dgts. Resolution: Current: - 0.01 A Environmental:1] Working Temp : 0 to 55º C 2] Storage Temp : 10 to 70º C 3] Relative humidity : 0 – 95 % NonCondensing 4] Warm up time : 10 Sec Enclosure: 1] Mounting 2] Enclosure 3] Terminal LED Indications: RED LED: Motor 1 (RWP) and Motor2 (HPP): Over Load, Current Unbalance, and Single Phase Faults. Green LED: If auto Mode Green LED turns ON for manual mode Green LED is turned off And on LED display ‘MAN’ is displayed. KEYS: • SET : This key is used to change the controller from RUN mode to • FUNCTION mode for parameter setting • INC : Up scroll the parameter & : Panel mounting. (Cut Out Size: 182(H) X 92(W) : 105 (W) X 200 (L) X 193 (H) mm. : Screw ON Terminals. 1 USER MANUAL PROTON POWER CONTROL PVT. LTD., PUNE parameter value. : Down scroll the parameter & parameter value, For manual reset of Fault. Note: To Load default parameter Press INC key on power ON. Front Switches: 1. Auto / Manual selection switch. 2. RWP (Motor1) manual ON/OFF control 3. HPP(Motor 2) manual ON/OFF control • SPP fault for the same is disabled for the motor which is selected as single phase. Current, displayed will be of the connected phase. DEC SETTINGS: Sr. Parameter No 1 Over Load : oLHP 2 Over Load : oLrP 3 Unbalance Current : ubHP 4 Unbalance Current : ubrP 5 Over Load trip Delay : oL trp 6 Unbalance Current trip Delay: ub trp 7 HPP Motor ON Delay : HPon 8 RWP Motor ON Delay : HPon 9 HPP Single/Thr ee Phase * 10 RWP Single/Thr ee Phase * 11 Display Currents Enable : dISP (If disabled, shows AUTO / MAN selection) Mi n 2.0 Max Default Unit 13.0 5.0 Amp 2.0 13.0 5.0 Amp 20 50 40 20 50 40 1 30 5 % of Over Load % of Over Load sec 1 30 5 sec 5 300 10 sec 5 300 10 sec CONTROLLER FUNCTIONS: Password is 11 for Overload setting, 20 for rest parameter settings & password 5 is for displaying currents for one cycle. Procedure to change parameter settings: 1. Press SET key. 2. Enter Correct Password. 3. Wait to check password. 4. Using UP Arrow & down Arrow key user can change setting parameters. 5. Press UP Arrow Key to increment parameter value up to maximum limit. 6. Press down Arrow key to decrement parameter value down to minimum limit. 7. To save the settings (value) wait for five seconds Note: 1. Calibration setting is for Factory Setting only. 2. For manual reset of faults, press Decrement Key. 3. Password 5 is applicable only When display current enable mode is disabled. 4. To Load default parameter Press INC key on power ON. Field Terminal Layout: Back View: R 1P 3P 3P NA 1P 3P 3P NA no yes yes NA 1PHASE HPP OUTPUT 3PHASE HPP OUTPUT AC SUPPLY 3P 415V 50Hz Y TO HPP CONTACTOR C 2 NO B N R TO RWP CONTACTOR C NO Y B HPP ON C NO 1PHASE RWP OUTPUT 3PHASE RWP OUTPUT N R B Y N MPV POWER DOSING PUMP L L N N USER MANUAL PROTON POWER CONTROL PVT. LTD., PUNE FLOWCHARTS: H ENTER PASSWORD =5 IF FUNCTION KEY PRESSED NO SET OL TRIP DELAY? (DEFAULT 5s) NO ENTER YES FUNCTION MODE SELECTED DISPLAY HPP/RWP CURRENT ENTER PASSWORD RUN MODE SET UB TRIP DELAY? (DEFAULT 5s) NO DECREMENT OR INCREMENT(1s-30s) ENTER YES B DECREMENT OR INCREMENT(1s-30s) SET HPP ON NO DELAY? (DEFAULT 10s) YES DECREMENT OR INCREMENT(5s-100s) NO PASSWORD =11 YES G SET RWP ON DELAY? (DEFAULT 10s) DISPLAY SETTING PARAMETERS NO NO RWP MOTOR SET? DEFAULT 3PH DECREMENT OR INCREMENT(2A-13A) NO SET OLRP? DEFAULT 5A NO DISPLAY SET? DEFAULT YES DECREMENT OR INCREMENT(2A-13A) NO SET UBHP? DEFAULT 40% NO PASSWORD CHANGE? DEFAULT 11 DECREMENT OR INCREMENT(20%-50%) DECREMENT OR INCREMENT(YES/NO) ENTER YES YES DECREMENT OR INCREMENT(1PH-3PH) ENTER YES YES DECREMENT OR INCREMENT(5s-100s) ENTER YES ENTER YES SET OLHP? DEFAULT 5A ENTER YES NO DECREMENT OR INCREMENT(0-9999) YES YES FUNCTION TIME OUT? SET UBRP? DEFAULT 40% NO NO G DECREMENT OR INCREMENT(20%-50%) YES YES RUN MODE H TM PROTON PROTON POWER CONTROL PVT. LTD. S. NO. 28, JAGTAP DAIRY, PIMPLE NILAKH, PUNE – 411027. TEL: 020-2727 0800, 27276777 TEL/FAX: 020-2727 0100 MOBILE: 9764885010/9422009655 E-MAIL: [email protected] [email protected] 3 B