4.16.8 List:Voltage
LIST:VOLTage
Phase Selectable
This command specifies the output voltage points in a list. The voltage points are given in
the command parameters, which are separated by commas. The order in which the points
are entered determines the sequence in which the list will be output when a list transient is
triggered.
Command Syntax
Parameters
Unit
Examples
Query Syntax
Returned Parameters
Related Commands
[SOURce:]LIST:VOLTage[:LEVel] <NRf+>,<NRf+>
Value depends on the voltage range and the voltage mode
V (rms voltage)
LIST:VOLT 2.0,2.5,3.0
LIST:VOLT MAX,2.5,MIN
[SOURce:]LIST:VOLTage[:LEVel]?
<NR2>
LIST:VOLT:POIN?
LIST:COUN
LIST:DWELLIST:STEP
LIST:SHAP
LIST:VOLT:OFFS
LIST:VOLTage:POINts?
Phase Selectable
This query returns the number of points specified in LIST:VOLT. Note that it returns only the
total number of points, not the point values.
Query Syntax
Returned Parameters
Example
Related Commands
[SOURce:]LIST:VOLTage:POINts?
<NR1>
LIST:VOLT:POIN?
LIST:VOLT
LIST:VOLTage:SLEW
Phase Selectable
This command specifies the output offset slew points in a list. The slew points are given in
the command parameters, which are separated by commas. The order in which the points
are entered determines the sequence in which the list will be output when a list transient is
triggered. Changing list data while a subsystem is in list mode generates an implied ABORt.
Command Syntax
Parameters
Unit
Example
Query Syntax
Returned Parameters
Related Commands
iM Series / i Series / iX Series
[SOURce:]LIST:VOLTage:SLEW <NRf+>,<NRf+>
0.1 to 1E9 | MAX
V/S (volts per second)
LIST:VOLT:SLEW 10, 1E2, MAX
[SOURce:]LIST:VOLTage:SLEW?
<NR2>
LIST:VOLT:SLEW:POIN?
LIST:COUN
LIST:DWEL
LIST:STEP