Download Rev AB - AMETEK Programmable Power

Transcript
AC Source SCPI Programming Manual
California Instruments
6.2.5 Programming the Output Phase
You can control the phase of the AC voltage waveform relative to an external reference with:
PHASe <n>
which sets the phase in degrees. If <n> is positive, the voltage waveform leads the internal
reference or phase A value in three phase configuration.
For the 15003i, 15003ix-clk and 30003ix-clk (three phase three controller clock and lock
configurations), the PHASe command sets the relative phase of B and C with respect to
phase A.
6.2.6 Current Limit
This command will set the rms current limit, to set this limit is:
CURRent <n>
where <n> is the rms current limit in amperes.
If the load attempts to draw more current than the programmed limit, and the source is set
for constant current mode, the output voltage is reduced to keep the rms current within the
limit. Since the rms detection involves a filter time constant that is long compared to a single
output cycle, the response time of the rms current limit is not instantaneous.
The AC source can be programmed to turn off its output if the rms current limit is reached.
This protection feature is activated when the source mode is set for constant voltage mode.
Note:
The CURRent command is coupled with the VOLTage:RANGe.This
means that the maximum current limit that can be programmed at a
given time depends on the voltage range setting in which the unit is
presently operating. Refer to "Coupled Commands" for more
information.
6.2.7 Waveform Shapes
At *RST, the AC/DC power source generates a sine waveform when in AC or AC+DC mode,
but other shapes can be selected. There are built-in tables for sine, square and clipped sine
waveforms. In addition, the user can define arbitrary waveshapes by creating a 1024 point
table of amplitudes for a single cycle.
As shown in the following examples, the FUNCtion[:SHAPe] command selects the output
waveform.
Square Waveform
To select the square output waveform, use:
FUNCtion:SHAPe SQUare
Clipped Waveform
To select a clipped sine waveform use:
FUNCtion:SHAPe CSINe
To set the clipping level to 10% THD, use:
FUNCtion:SHAPe:CSINe 10
The clipping level is specified in terms of the percent total harmonic distortion in the clipped
sine waveform.
User-Defined Waveform
iM Series / i Series / iX Series