CubeSuite+ V2.00.00 CHAPTER 4 ASSEMBLY LANGUAGE SPECIFICATIONS - The .db directive cannot be described in a bit section. - Two or more initial values may be specified within a statement line of the .db directive. - As an initial value, an expression that includes a relocatable symbol or external reference symbol may be described. - If the relocation attribute of the section containing the .db directive is BSS or SBSS, then an error is output, because initial values cannot be specified. [Example] .cseg text WORK1: .db (1) ; (1) WORK2: .db (2) ; (1) .cseg text MASSAG: .db "ABCDEF" ; (2) DATA1: .db 0xA, 0xB, 0xC ; (3) DATA2: .db (3 + 1) ; (4) DATA3: .db "AB" + 1 ; (5) <- Error (1) Because the size is specified, the assembler will initialize each byte area with the value "0". (2) A 6-byte area is initialized with character string 'ABCDEF' (3) A 3-byte area is initialized with "0xA, 0xB, 0xC". (4) A 4-byte area is initialized with "0x0". (5) This description occurs in an error. R20UT2659EJ0100 Rev.1.00 Jul 01, 2013 Page 243 of 911