List of Action Numbers
01/2008
No. 62
Definitions:
Deactivate skip slash blocks
(VDI signal: skip block)
Not permitted if:
1. The nesting depth is too great
Possible actions:
1. Wait until previous ASUB has finished or cancel program
No. 63
Definitions:
Activate test run.
(VDI signal: rapid traverse override)
Not permitted if:
1. The nesting depth is too great
2. If there is a reorganize brake error
Possible actions:
1. Wait until previous ASUB has finished or cancel program
2. Cancel program
No. 64
Definitions:
Deactivate test run.
(VDI signal: rapid traverse override)
Not permitted if:
1. The nesting depth is too great
2. If there is a reorganize brake error
Possible actions:
1. Wait until previous ASUB has finished or cancel program
2. Cancel program
No. 65
Definitions:
Activate read-in disable for main run block.
(VDI signal: read-in disable)
Should not occur in any alarm
No. 66
Definitions:
Deactivate read-in disable for main run block.
(VDI signal: read-in disable)
Should not occur in any alarm
No. 67
Definitions:
Stop at the block boundary (alarm)
Should not occur in any alarm
No. 68
Definitions:
Stop all axes (alarm)
Should not occur in any alarm
No. 69
Definitions:
3-934
Activate program test.
(VDI signal: program test)
Not permitted if:
1. Tool management is active
2. The NCK channel status is not Ready
Possible actions:
1. Backup tool data
2. Cancel program or process with reset button
or wait for end of program
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 01/2008