1.0 INTRODUCTION 1.1 FOREWORD Polycold’s Cool Solutions® low temperature gas chillers are used to allow low temperature vacuum processing of semiconductor device wafers as well as other applications. Vacuum processing systems use recirculating fluids to keep the wafer at controlled temperature. The wafer sits on a pedestal or table in a vacuum and is processed, typically in a vacuum with specific gases and metallic vapors to create a uniform coating on it. Gas circulating in the secondary loop of the 1XCL closed loop gas chiller is cooled in the gas chiller. The temperature of the gas leaving the gas chiller can reach temperatures of –100oC. The chilled gas is recirculated by a secondary gas compressor. The customer-installed lines connecting the gas chiller and the pedestal are vacuum jacketed to minimize the heat leaks from the ambient to the chilled gas. The system consists of a refrigeration system, which chills the secondary gas, a secondary gas recirculating compressor, interconnecting gas lines and the table in the vacuum system. The refrigeration system uses a propriety and patented blend of refrigerants. The secondary loop compressor uses an inert gas whose dew point is below –80oC. The refrigeration system as well as the secondary gas loop requires cooling water. There is no co-mixing of the refrigerant and the secondary gas. The equipment is designed for continuous operation. Electricity, cooling water, and pressurized dry nitrogen are the only required utilities. Pressures are stated as gauge, not absolute. Psig is pounds per square inch gauge and kPa is Kilopascals gauge. kPa = 6.895 x Psig bar = Psig 14.5 This technical manual contains Safety, Service, Introduction, Specifications, Installation, Operation, Maintenance, and Parts information for all the equipment in the system. Notes: REVIEW THE INSTRUCTION MANUAL BEFORE OPERATING THIS EQUIPMENT! This unit was shipped with a shipping bolt to secure the compressor for transport. It must be removed to prevent excess vibration. Failure to do so may void your warranty. Before shipping this unit the shipping bolt must be re-installed to prevent damage during shipping. Failure to do so may void your warranty. Refer to section 2.3, Item 3. Upon arrival of the equipment and prior to starting its installation or operation confirm that the balance pressure (BP) shown on the suction pressure gauge is between 140 – 160 psi. Refer to section 2.3, Item 2. 825130-00 REV B Page 4