Para
meter
No.
F2-01
Name
Setting
range
Default
setting
Sets the functions for channel 1
to 3 which are effective when
the 3G3IV-PAI14B Analog
Reference Card is used.
0: 3-channel individual
(Channel 1: terminal 13,
Channel 2: terminal 14,
Channel 3: terminal 16)
1: 3-channel addition (Addition
values are the frequency
reference)
Note: When set to 0, select 1 for
b1-01. In this case the
multi-function input “Option/Inverter selection”
cannot be used.
0, 1
Sets the Digital Reference Card
input method.
0: BCD 1% unit
1: BCD 0.1% unit
2: BCD 0.01% unit
3: BCD 1 Hz unit
4: BCD 0.1 Hz unit
5: BCD 0.01 Hz unit
6: BCD special setting (5-digit
input)
7: Binary input
Note: Setting “6” is effective
only when the 3G3FVPDI16H2 is used, but the
input will be BCD and the
units will be set in o1-03 if
01-03 has been set to “2”
or higher.
0 to 7
Display
name
Analog
Reference
Card
selection
AI-14 Input
Sel
F3-01
Description
Digital
Reference
Card input
selection
DI Input
Note: When F3-01 is set to “7”,
input the following values
as the max. frequency.
3G3IV-PD108: FF hex (255
decimal)
3G3FV-PD116H2: FFF hex
(4,095 decimal) for 12 bits or
7530 hex (30,000 decimal) for
16 bits
7-32
Control mode
0
Changes
during
operation
NO
B
0
NO
B
V/f
control
V/f
with
PG
Page
Open
loop
vector
Flux
vector
B
B
B
6-71
B
B
B
6-72