Download VS1MD User Manual - Perceptive Industries
Transcript
When override function is used, select the Main/Aux. speed according to loads used. Group Code I/O group Parameter Name Setting Unit t36 [NV Input Min Voltage] 0 V t37 [Frequency Corresponding to t36] 0.00 Hz t38 [NV Input Max Voltage] 10.00 V t39 [Frequency Corresponding to t38] 5.00 Hz t41 [V1 Input Min Voltage] 0 V t42 [Frequency Corresponding to t41] 0.00 Hz t43 [V1 Input Max Voltage] 10 V t44 [Frequency Corresponding to t43] 5.00 Hz t46 [I Input Minimum Current] 4 mA t47 [Frequency Corresponding to t46] 0.00 Hz t48 [I Input Max Current] 20 mA t49 [Frequency Corresponding to t48] 60.00 Hz After the above parameters are set, if 5V is applied to V1 with 12mA given to terminal I, output frequency would be 32.5Hz. If –5V is applied to V1 terminal with 12mA given to terminal I, output frequency would be 27.5Hz. 8.1.6 Frequency Setting via 0 to 10V + 0 to 20mA Input Group Drive group Code Parameter Name Setting Range Initial P37 [Frequency Command] - 0 to 400 0.00 P40 [Frequency Mode] 6 1 to 7 1 Unit Hz Step 1. Set P40 [Frequency Setting Method] to “6”. Step 2. Related code: t40 to t44, t45 to t49 Step 3. Refer to Frequency setting via -10 to +10V voltage input + 0 to 20mA input. 8-6 VS1-MD AC Drive User Manual