Download VPF-710- User Manual
Transcript
Calibration Procedures Section 5 CALIBRATION CHECK NOTES PLEASE READ THESE NOTES BEFORE CONTINUING The EXCO (Extinction Coefficient) values depend heavily on the location and prevailing weather conditions and should only be carried out with the sensor: 1. MOUNTED OUTSIDE AND ON A CLEAR DAY (VISIBILITY>10KM) 2. POWERED FOR AT LEAST 1 HOUR 3. NOT LOCATED NEAR A WALL OR OTHER OBSTRUCTION 4. NOT RECEIVING OPTICAL REFLECTIONS (FROM SURFACES OR CLOTHING) Assembly of the calibration plaque to the sensor The calibration reference plaque should first be attached to the arm. Confirm that the serial number marked on the calibration reference plaque matches that on the label on the calibration arm. If not, do NOT use this assembly as it may not give a true calibration. This assembly should then be attached to the sensor as shown in Figure 5-1 - Assembly of Calibration Reference Plaque. Note: All commands should be terminated with <Carriage Return> and <Line Feed> <crlf>, (see Paragraph 1.3). The figure shows the calibration plaque assembly fixed to a VPF730, but the same configuration is used for the VPF710 and VPF750. Calibration Reference Plaque Calibration arm Figure 5-1 - Assembly of Calibration Reference Plaque (Example of calibration plaque in-situ on VPF730) 62 Calibration Check