Download danger - Schneider Electric
Transcript
! DANGER HAZARDOUS VOLTAGE This product contains energy storage devices. Read and understand this bulletin as well as bulletins supplied with your specific equipment before maintaining or servicing the ALTIVAR 66 Drive controller. Installation, adjustment, service and maintenance of these drive controllers must be performed by qualified personnel. • Confirm that drive controller has been correctly selected, installed, and applied before performing any service or maintenance. • Verify that all drive controller overcurrent protective devices, conductors, enclosures, and other circuit elements have been correctly selected for application and that drive controller is properly grounded in accordance with equipment instruction bulletin recommendations and applicable code requirements. • Some measurements must be done with power applied to equipment. Many parts in this drive controller, including printed circuit boards, operate at line voltage. DO NOT TOUCH. Use personal protective equipment and follow precautions and measurement procedures referenced in this bulletin when making any measurements on energized equipment. Use instruments and insulated tools approved for job. • Disconnect all power before servicing drive controller. WAIT ONE MINUTE until DC bus capacitors discharge, then measure DC bus capacity or voltage between the PA and (-) terminals to verify that DC voltage is less than 45 VDC (refer to “PROCEDURE 1: BUS VOLTAGE MEASUREMENT” in Chapter 5). DC bus LED is not accurate indication of absence of DC bus voltage. • DO NOT short across DC bus capacitors or touch unshielded components or terminal strip screw connections with voltage present. • Install all covers and close drive controller door before applying power or starting and stopping drive controller. • Observe and follow all applicable lock-out and tag-out procedures for specific installation. Failure to follow these instructions will cause shock or burn, resulting in death or serious injury. ALTIVAR is a trademark of Telemecanique S.A. or its successor-in-interest, Schneider Electric S.A. Thermalcote is a registered trademark of Thermalloy, Inc. Thermstrate‘ is a trademark of Power Devices, Inc. Torx is a registered trademark of Textron, Inc. © 1996 Square D All Rights Reserved. This document may not be copied in whole or in part, or transferred to any other media without the written permission of Square D. Electrical equipment should be serviced only by qualified electrical maintenance personnel. No responsibility is assumed by Square D for any consequences arising out of the use of this material.