Download Manual
Transcript
NOTE With local sensing it is important to minimize the wire length and resistance. Also the positive and negative wire resistance should be close as possible to each other to achieve current balance between power supplies. +S To J1-10 SLAVE#2 POWER SUPPLY -S +S MASTER POWER SUPPLY J1-25 P IPGM J1-8 J1-12 J1-10 To J1-23 SLAVE#2 POWER SUPPLY -S Twisted pair As short as possible -V Twisted pair CAUTION Make sure that the connection between -Vo terminals is reliable to avoid disconnection during operation. Disconnection may cause damage to the power supply. +S J1-12 COM + IPGM_RTN J1-23 - LOAD +V SLAVE#1 POWER SUPPLY -S +V -S -V +S Twisted pair -S +S Fig.5-5: Parallel operation with Remote sensing 5.16 DAISY-CHAIN CONNECTION It is possible to configure a multiple power supply system to shut down all the units when a fault condition occurs in one of the units. When the fault is removed, the system recovers according to its setting to Safe start mode or Automatic restart. Setup switch SW1 position 5 should be set to its Down position to enable the Daisy-chain operation. Other SW1 positions can be set according to the application requirements. If a fault occurs in one of the units its PS_OK signal will be set to low level and the display will indicate the fault. The other units will shut off and their display will indicate "SO”. When the fault condition is removed, the units will recover to their last setting according to their Safe start or Auto-restart setting. Fig.5-6 shows connection of three units, however the same connection method applies to systems with a larger number of units. POWER SUPPLY J1-2,3 #1 J1-16 IF_COM POWER SUPPLY J1-2,3 J1-15 #2 J1-16 IF_COM PS_OK SO POWER SUPPLY #3 J1-15 PS_OK SO J1-2,3 J1-16 IF_COM J1-15 PS_OK SO Fig.5-6: Daisy-chain connection 5.17 FRONT PANEL LOCKING The front panel controls can be locked to protect from accidental power supply parameter change. Press and hold PREV button to toggle between “Locked front panel” and “Unlocked front panel”. The display will cycle between “LFP” and “UFP”. Releasing the PREV button while one of the modes is displayed, selects that mode. 5.17.1 Unlocked front panel In this mode, the front panel controls are enable to program and monitor the power supply parameters. 5.17.2 Locked front panel In this mode the following front panel controls are disabled: - VOLTAGE and CURRENT encoders. - FOLD button. - OUT button. The power supply will not respond to attempts to use these controls. The VOLT display will show “LFP” to indicate that the front panel is locked. OVP/UVL button is active to preview the OVP and UVL setting. Use PREV button to preview the output voltage and current setting or to unlock the front panel. 43