Download User Manual
Transcript
ADT-CNC4240 铣 床 数 控 系 统 Unit : LOGIC VOLTAGE LEVEL User : Super Administrators Initialization : 0 Effective time : Immediately Explain : After this parameter is set and used, the System will automatically use phase Z for locating in mechanical zero mode. It is called “servo zero” localization. Under this mode, the precision of repeated returning to zero positioning depends on the precision of the servo positioning, so normally we suggest start this function when use the servo. Because the stepper motor do not has the coder, it can not start this function, or there will be a fault when the tool return to zero it can not find signal. 017 X-axis positive limit of hardware(restart) 018 X-axis negative limit of hardware(restart) 019 X-axis limit the effective signal(restart) 020 Y-axis positive limit of hardware(restart) 021 Y-axis negative limit of hardware(restart) 022 Y-axis limit the effective signal(restart) 023 Z-axis positive limit of hardware(restart) 024 Z-axis negative limit of hardware(restart) 025 Z-axis limit the effective signal(restart) 026 A-axis positive limit of hardware(restart) 027 A-axis negative limit of hardware(restart) 028 A-axis limit the effective signal(restart) Effective range Unit : 0~ 1 : Non User : Super Administrators Initialization : 0 Adtech CNC Co.,LTD - 168 -