ADT-CNC4240 铣 床 数 控 系 统
015
Permission
:
Operation admin
Default value
:
1( ABS)
Effective time
:
Instant
Description
:
Select default boot screen, including absolute position, relative position,
comprehensive position, and program position. The user can press Left or Right
to select in this menu.
System language pack
Range
:
0~ 1
Unit
:
None
Permission
:
Operation admin
Default value
:
0 (Chinese)
Effective tim
e
:
Instant
Description
:
Select system language
0: Chinese
1: English
016
Macro keyword effective enable
Range
:
0~ 1
:
None
:
Operation admin
Default value
:
0
Effective time
:
Instant
Description
:
4240 has mask with macro keyword and universal mask. If it is not required to
enable macro keyword input, please set it to o to disable this function, in which
the input will be quicker.
Unit
Permission
017
Boot screen display mode
Range
:
0~ 5
Unit
:
None
Permission
:
Operation admin
Default value
:
2
Adtech CNC Co.,LTD
- 183 -