Improved Control Performance A Wide Range of Applications Realizes the industry-leading control performance Ratings for intended use The operation mode for the motor is selected according to motor load condition. Motors larger by one or two frames can be driven with medium load (MD) and light load (LD) use. Induction motor Achieved speed response of 600 Hz Follow-up characteristics under impact load (Tested with a dedicated motor with PG under vector control with speed sensor: about six times greater than our conventional model) 25.0 dB Specification Applied load HD High Duty Spec Powerful drive at low noise MD Middle Duty Spec Can drive motors of frames one size larger *1 LD dBMg 100% Torque current command value -25.0 dB 1 10 100 Actual speed value 0.0 deg 100r/min Motor current Phase (deg) Low Duty Spec Can drive motors of frames one or two sizes larger *1 Applicable overload rating 10 100 1000 Load ON(100%) Frequency Hz Load OFF(0%) FRN7.5VG1S-2J(600Hz, -3dB) FRN7.5VG7S-2(105Hz, -3dB) * With the stack type, "100 Hz" is achieved. Uneven rotation reduced by one-third Speed and torque characteristics 400V 3.7 to 630 Stack Type*2 400V 110 to 450 *2 200V 37 to 110 400V 37 to 710 30 to 800 37 to 1000 Note)A DCL may be selected according to applicable specifications. *1 This varies depending on motor specifications and power supply voltage (unit type only). *2 Carrier frequency becomes 2kHz. Control method Not only the induction motors but also the synchronous motors can be driven, and for the induction motors, you can select the most suitable control method according to your individual needs. Having a standard built-in brake circuit (with 200V 55kW or less and 400V 160KW or less), is useful when applying the inverter to the vertical transfer machine, which is frequently used under the regenerative load. Target motors Control method Induction motor -Vector control with speed sensor -Speed sensorless vector control -V/f Control Synchronous motor - Vector control with speed sensor (including pole position detection) A wide range of options - Providing options supporting various interfaces such as high-speed serial communications - Options can be used by just inserting them into the connectors inside the inverter. Up to five cards can be mounted. Under vector control with sensor * Compared with our conventional models 0.75 to 90 Unit type:120% 1min Stack type:110% 1min - Position control by built-in APC - The ABS encoder I/F option card with 17-bit high resolution has been prepared. - Pulse train input enabled (optional) - The option card for the SX and E-SX bus I/F has been prepared. FRN37VG1S-4J, at 500r/min operation FRN7.5VG5S-2(54Hz, -3dB) 200V 150% 1min Servo function 0.5s Unit Type 200V * Unit type only -360 deg 1 Applicable motor capacity [kW] Power supply voltage Current: 150% 1min/200% 3sec A standard built-in brake circuit with expanded capacity range 1000 Frequency Hz Feature (For details, please contact us because the combination of the optional cards has some restrictions.) Categoly Analog card FRN37VG1S-4J Digital card (for 8-bit bus) 0.5r/min Axial torque (%) 0.5r/min OPC-VG1-FV*1 Analog input/output interface expansion card OPC-VG1-AIO Digital input OPC-VG1-DI OPC-VG1-DIO PG interface card 50 -50 1000 2000 3000 Rotation speed (r/min) PG card for synchronous motor drive OPC-VG1-PG Open collector OPC-VG1-PGo ABS encoder with 17-bit high resolution OPC-VG1-SPGT Line driver OPC-VG1-PMPG Open collector OPC-VG1-PMPGo OPC-VG1-TL CC-Link communication card OPC-VG1-CCL High-speed serial communication card (for UPAC) OPC-VG1-SIU*1 SX bus communication card OPC-VG1-SX E-SX bus communication card OPC-VG1-ESX User programming card OPC-VG1-UPAC*1 PROFINET-IRT communication card OPC-VG1-PNET*1 Safety card Functional safety card OPC-VG1-SAFE Field bus interface card PROFIBUS-DP communication card OPC-VG1-PDP*1 DeviceNet communication card OPC-VG1-DEV*1 Terminal block for high-speed communications OPC-VG1-TBSI -100 Digital card (for 16-bit bus) FRN37VG1S-4J Control circuit terminal *1 comming soon 4 +5V line driver T-Link communication card -150 at 30r/min operation F/V converter 100 0 Type OPC-VG1-SN*1 Digital input 150 Conventional model FRN37VG7S-4 Name Synchronized interface 5