The data demonstrates that the heat exchanger efficiency is nearly the 90% as shown in figure 6.24 Figure 6.24 – HAVC’s heat exchanger efficiency 6.2.4 Conclusion of the first on-field study The first results analyzed are showing that mechanical ventilation plays an important role in limiting the CO2 and humidity levels. The heat exchanger efficiency, referring at UNI EN 308/1998, reaches values of almost 90%. Moreover, the data will be analyzed in relation to the habits of the inhabitants by monitoring also some parameters such as the state of the windows (opened or closed), the effective presence of people in the rooms and energy consumption of the dwelling in relation to the adopted ventilation systems (natural or mechanical). The energy recovery is close to the theoretically value of 90% provided (by Aldes France) although Indoor Air Quality (IAQ) level (of inhabitants) can be improved. 6.3 On-field test application II Aim of this second study was to demonstrate that between healthy subjects and subjects with Parkinson’s disease and Ataxia objective detectable differences can be found in the average accelerations, obtained with an 190