Download EXPERT PN110
Transcript
EXPERT PN110 • Press the down-arrow key in order to select the "Cold Start Temp." menu. Accessible if the stir fans' cold temperature function is enabled above. • Press the Edit key then use the arrow keys to set the start temperature to the desired value. Press the Edit key once again to validate. • Press the down-arrow key. The stop temperature flashes on the display. • Press the Edit key then use the arrow keys to set the stop temperature to the desired value. Press the Edit key once again to validate. 5.7.4 5.7.5 If the Cold Temp. and/or Probe Diff. functions have been enabled, the stir fans will operate following a timer. These two functions share the same timer. The timer's On and Off times can be adjusted from 0 minutes, 0 seconds to 60 minutes, 0 seconds. • Set the function to START/STOP TEMPERATURES from the main menu, using the menu select buttons. • Select the "6. Stir Fan" menu. Accessible if the stir fan output is enabled (sec. 5.16.3). Probe Diff. : 5.0 Cold & Probe Timer On Time 1:00(m:s) Off Time 1:00(m:s) Probe Difference Settings If the probe temperature difference function is used, you must define the maximum allowable temperature difference between two probes. Whenever the temperature between two probes exceeds this value, the stir fan output starts to operate following a timer. The temperature difference ranges from 0.5°F to 20°F (0.3°C to 11.1°C). • Set the function to START/STOP TEMPERATURES from the main menu, using the menu select buttons. • Select the "6. Stir Fan" menu. Stir Fans Timer Settings • Press the down-arrow key to select the "On Time" menu. Accessible if the stir fans' cold temperature and/or probe difference functions are enabled above. • Press the Edit key then use the arrow keys to set the On Time to the desired value. Press the Edit key once again to validate the value. • Press the down-arrow key once. The Off Time flashes on the display. • Press the Edit key then use the arrow keys to set the Off Time to the desired value. Press the Edit key once again to validate the value. Accessible if the stir fan output is enabled (sec. 5.16.3). Probe Diff. : 5.0 Cold & Probe Timer On Time 1:00(m:s) Off Time 1:00(m:s) • Press the down-arrow key to select the "Probe Diff." menu. Accessible if the probe difference function is enabled above. • Press the Edit key then use the arrow keys to set the temperature difference between two probes above which the stir fans start operating. Press the Edit key once again to validate. EXPERT PN110 rev.12 35