Download Inertial Unit: Watson
Transcript
IMU-E604 Manual, Revision G 3.4 Heading Analog Resolution Accuracy Repeatability Digital 0.09° 0.03° ±3° to 30 Degrees Angle* Better Than 0.5°, Analog and Digital Analog Scale: 0-360° (18°/Volt), South = ±10 VDC, West = -5 VDC, North = 0 VDC, East = +5 VDC *Accuracy of the unit is greatly dependent upon field calibration. Even with perfect calibrations, field variations in the magnetic declination will affect accuracy. 3.5 Other Specifications Power Requirement +12 VDC, < 600 mA Size See Drawing, Appendix F Weight < 4 Pounds Shock (Survival) 600 g's Temperature Range Operating: Survival: -30°C to +71°C -40°C to +85°C 4.0 Output and Interface The IMU has both an analog and a digital interface. To prevent hardware/software conflicts, all analog switches are disabled when the following RS-232 commands are sent to the unit. Reference Command Velocity Command Coast Mode Command 4.1 Analog Outputs The analog outputs have a full scale range of ±10 VDC and come from a 12 bit digital to analog converter. The following outputs are available. Their full scale ranges are listed in the second column. Roll* Pitch* Heading* X Acceleration Y Acceleration Z Acceleration Forward Acceleration Lateral Acceleration Vertical Acceleration X Rate Y Rate Z Rate Phone: (715) 839-0628 ±180° ±180° ±180° (North = 0 VDC) ±2 g’s ±2 g’s ±2 g’s ±2 g’s ±2 g’s ±2 g’s ±100°/sec ±100°/sec ±100°/sec Fax: (715) 839-8248 EMail: [email protected] 13