Basic Operation
Battery Operation
Check the remaining battery capacity. If it is 20% or less before operation, splicer can only
work a few times.
Keep below practices to prevent battery damage.
Fully charge the battery after every use.
Follow below conditions
Operation
: -10 degree C ~ 50 degree C
Charging
: 0 degree C ~ 40 degree C
Storage
: -20 degree C ~ 30 degree C
How to charge the battery
Charge of battery pack BTR-10 is started where AC adaptor ADC-19 is connected to
an inlet. The charge LED (orange) blink and battery charging starts. It takes about 4
hours to charge the battery and the turn off the LED. Pull out the plug of AC power
cord after charging. It is possible to use the splicer during operation.
Charge will be started if a power supply is
supplied from ADC-19.
Please check the charge state in main part
sheet key LED.
Power supply ON state
Normal
Charging
Power supply OFF state
LED : ON green
Check the battery
capacity
LED : OFF
Battery mark
LED:Blink orange
operates
4 hours to charge
4 hours to charge
the battery
the battery
LED: Orange Blink quickly(OFF state)
Refer to *1
*1
When LED blinks at the time of charge it is too early and degradation of a battery and
failure can be considered. Charge is not performed.
Exchange for New BTR-10.
14