Download Telindus 2400 series

Transcript
Telindus 2400
Chapter 6 113
User manual
6.6.4
Basic configuration
Loading the default configuration using a DIP switch
The following procedure shows how to load the default configuration using the Load Default Configuration DIP switch on the Telindus 2400 PCB:
Step
Action
1
Disconnect the power supply and open the housing as described in 3.3 - Opening and
closing the housing on page 40.
2
Set DIP switch bank DS1 position 2 to off.
Refer to 3.1 - The Telindus 2400 motherboard on page 38 to locate this DIP switch bank.
3
Slide the bottom in the cover again without fastening the screws and reconnect the power
supply.
⇒The Telindus 2400 reboots and loads the default configuration.
4
Activate the loaded default configuration:
Step
Action
1
Open a TMA session on the Telindus 2400. Refer to 4.1 - Maintaining
the Telindus 2400 with TMA on page 42.
2
Execute the Activate Configuration action.1
1. If you are performing this load default configuration procedure because you
accidentally made a configuration error, you have the possibility to retrieve
this erroneous configuration before executing the Activate Configuration command. In that case you do not have to reconfigure the complete device
again, but you only have to correct the error in question. Retrieve the erroneous configuration by executing the Load Saved Configuration command.
5
Again, disconnect the power supply and open the housing.
6
Reset DIP switch bank DS1 position 2 to on.
7
Properly replace the cover as described in 3.3 - Opening and closing the housing on
page 40 and reconnect the power supply.