Download Chapter 2 -- Air Conditioning Component Service

Transcript
45
STEP 76
STEP 77
RD00H207
1
Turn the flushing valve to the AIR position. Allow air
to flow through the circuit until no noticeable mist is
discharged.
NOTE: Air pressure is the only means to remove the
flushing solvent from the A/C system, and no solvent
must remain in the system when it is evacuated and
recharged.
2
RH01F112
1. FROM THE FLUSH TANK
2. TO RETURN BUCKET
STEP 78
Close the flushing and air valves. Reverse hose
connections for forward flushing. Connect the hose
from the flush tank to the discharge line; connect the
hose to the return bucket to the suction line. Open
flushing and air valves and repeat flushing until the
solvent is clear.
RP00G018
Turn the flushing valve to the CLOSED position.
Disconnect the flushing and drain hoses and
adapters from the compressor lines.
Install the flushing tank hose quick coupler on the
evaporation plug to prevent evaporation of the
solvent remaining in the tank during storage.
See Post Flushing Procedures, page 48.