Download USER`S MANUAL - Automatisation JRT

Transcript
TABLE OF CONTENT
1.
LCD USE (JRT-LCD): ............................................................................................................................................................ 1-1
1.1.
1.2.
2.
KEYBOARD: ................................................................................................................................................................... 1-1
MENUS: .......................................................................................................................................................................... 1-2
1.2.1. Monitoring menu: ............................................................................................................................................ 1-3
1.2.2. Register Access menu: ..................................................................................................................................... 1-4
1.2.3. Active faults list menu: ..................................................................................................................................... 1-6
1.2.4. Construction mode menu: ................................................................................................................................ 1-6
1.2.5. Recording floor position menu: ....................................................................................................................... 1-7
1.2.6. Elevator options menu: .................................................................................................................................... 1-7
1.2.7. Password menu: ............................................................................................................................................... 1-8
USE OF THE PROGRAMMING CONSOLE (PRO01 OU PRO27): ................................................................................. 2-1
2.1.
2.2.
2.3.
PROGRAMMING CONSOLE CONNECTION: ........................................................................................................................ 2-1
2.1.1. On the CJ1M PLC: .......................................................................................................................................... 2-1
2.1.2. On the CPM2C PLC: ....................................................................................................................................... 2-1
VISUALISING AND MODIFYING A DM (ELEVATOR CONFIGURATION): ............................................................................. 2-2
CONSULTING THE ALARMS: ............................................................................................................................................ 2-2
3.
TEMPORARY START-UP: ................................................................................................................................................... 3-1
4.
FINAL START-UP: ................................................................................................................................................................. 4-1
5.
CONTROLLER TYPE: .......................................................................................................................................................... 5-1
5.1.
5.2.
5.3.
5.4.
5.5.
6.
OPERATION PRINCIPLE FOR CAR ZONING AND LEVELLING: ............................................................................. 6-1
6.1.
6.2.
6.3.
6.4.
6.5.
7.
TWO CAR GROOP CONTROLLER (WITHOUT DISPATCHER):............................................................................................... 5-1
GOUP CONTROLLER (WITH DISPATCHER): ...................................................................................................................... 5-1
CLOCK SETTING ON DISPATCHER WITH OPERATOR SCREEN: ........................................................................................... 5-3
CALL DISPATCH CONFIGURATION, USING THE OPERATOR SCREEN:................................................................................. 5-4
PEAK HOURS SETTINGS:.................................................................................................................................................. 5-6
WITH A STANDARD TAPE SELECTOR (ZONING BY MAGNET PULSES): (IP8300 BIN4 W10): ............................................ 6-1
USING A PERFORATED TAPE OR A ENCODER ON THE GOVERNOR: ................................................................................... 6-5
6.2.1. Installation of the perforated tape: .................................................................................................................. 6-5
6.2.2. Installation of the standard tape selector and the governor encoder: ............................................................. 6-6
6.2.3. Installation of the "Door Zone" and bar code magnets at each floor .............................................................. 6-7
6.2.4. Magnets installation with IP1200-TP1 guide: ................................................................................................. 6-9
6.2.5. High speed counter verification:.................................................................................................................... 6-10
6.2.6. Recording of floors position: ......................................................................................................................... 6-11
6.2.7. Programming the number of holes for slowdown: ......................................................................................... 6-12
VERIFICATION OF THE HIGH SPEED COUNTER (COUNT LOSS): ...................................................................................... 6-13
DETECTING FLOORS HAVING A PROBLEM WITH THE BAR CODE MAGNETS: ................................................................... 6-14
HOISTWAY ACCESS TRAVEL ADJUSTMENT: .................................................................................................................. 6-15
6.5.1. With performed tape or encoder installed on the governor : ......................................................................... 6-15
6.5.2. With Standard tape: ....................................................................................................................................... 6-16
CONTROL TECHNIQUES UNIDRIVE SP DRIVE START-UP: ..................................................................................... 7-1
7.1.
7.2.
CONNECTIONS: ............................................................................................................................................................... 7-1
7.1.1. Isolation transformer connections: .................................................................................................................. 7-1
7.1.2. Encoder connections:....................................................................................................................................... 7-1
7.1.3. Motor connections: .......................................................................................................................................... 7-1
FUNCTIONNING OF THE DRIVE: ....................................................................................................................................... 7-2
7.2.1. Drive keyboard operation: ............................................................................................................................... 7-2
7.2.2. Modifying a drive parameter: .......................................................................................................................... 7-3