U
temp
//elno//
RP
nrep
ielno
RRP
nrrep
iielno
FIN
Parameters
U
: keyword to define uniform temperature data.
temp
: value of the uniform temperature. (Real)
elno
: list of user element numbers to which the uniform temperature is applied. (Integer)
RP
: keyword to indicate data generation from the previous / symbol.
nrep
: the number of times the data is to be generated. (Integer)
ielno
: user element number increment to be added each time the data is generated by the RP command.
(Integer)
RRP
: keyword to indicate data generation from the previous // symbol.
nrrep
: the number of times the data is to be generated. (Integer)
iielno
: user element number increment to be added each time the data is generated by the RRP command.
(Integer)
FIN
: keyword to denote the end of the uniform temperature data block.
5.4.7.4 NON-UNIFORM Element Temperature Data
To define non-uniform temperature on elements. An element can have a different value of temperature at each
node. The data required is a set of element (E) definitions followed by a set of nodal temperature values (T).
Mid-side temperatures are always linearly interpolated between the adjacent corner nodes.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates.
Page 5-187